Dosimetric changes with computed tomography automatic tube-current modulation techniques

被引:10
|
作者
Spampinato S. [1 ,2 ,4 ]
Gueli A.M. [1 ,2 ]
Milone P. [2 ,3 ]
Raffaele L.A. [1 ,2 ,3 ]
机构
[1] PH3DRA Laboratories (PHysics for Dating Diagnostic Dosimetry Research and Applications), Dipartimento di Fisica e Astronomia, Università di Catania and INFN-Catania, Via Santa Sofia 64, Catania
[2] Scuola di Specializzazione in Fisica Medica, Dipartimento di Scienze mediche chirurgiche e tecnologie avanzate “G. F. Ingrassia”, Scuola Facoltà di Medicina, Via Santa Sofia 78, Catania
[3] Unità Operativa Complessa di Radiodiagnostica e Radioterapia, Azienda Ospedaliero-Universitaria Policlinico di Catania, P. O. Gaspare Rodolico, Via Santa Sofia 78, Catania
[4] Department of Oncology, Aarhus University Hospital, Nørrebrogade 44, Aarhus
关键词
Anthropomorphic phantom; CTDI; DLP; Noise index; Radiochromic films;
D O I
10.1007/s12194-018-0454-5
中图分类号
学科分类号
摘要
The study is aimed at a verification of dose changes for a computed tomography automatic tube-current modulation (ATCM) technique. For this purpose, anthropomorphic phantom and Gafchromic® XR-QA2 films were used. Radiochromic films were cut according to the shape of two thorax regions. The ATCM algorithm is based on noise index (NI) and three exam protocols with different NI were chosen, of which one was a reference. Results were compared with dose values displayed by the console and with Poisson statistics. The information obtained with radiochromic films has been normalized with respect to the NI reference value to compare dose percentage variations. Results showed that, on average, the information reported by the CT console and calculated values coincide with measurements. The study allowed verification of the dose information reported by the CT console for an ATCM technique. Although this evaluation represents an estimate, the method can be a starting point for further studies. © 2018, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:184 / 191
页数:7
相关论文
共 50 条
  • [1] Assessment of the Patient-Specific Image Quality for Chest Computed Tomography with Automatic Tube-Current Modulation
    Huang, Y.
    Liu, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E515 - E515
  • [2] Considerations on an automatic computed tomography tube current modulation system
    Moro, Luca
    Panizza, Denis
    D'Ambrosio, Daniela
    Carne, Irene
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (04) : 525 - 530
  • [3] Setting up computed tomography automatic tube current modulation systems
    Martin, C. J.
    Sookpeng, S.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (03) : R74 - R95
  • [4] Automatic tube-current modulation in CT -: A comparison between different solutions
    Althén, JN
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 308 - 312
  • [5] Effects of tube potential selection together with computed tomography automatic tube current modulation on CT imaging performance
    Sookpeng, S.
    Martin, C. J.
    Krisanachinda, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : 809 - 831
  • [6] Effects of the Use of Automatic Tube Current Modulation on Patient Dose and Image Quality in Computed Tomography
    Yurt, Aysegul
    Ozsoykal, Ismail
    Obuz, Funda
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2019, 28 (03) : 96 - 103
  • [7] Techniques and applications of automatic tube current modulation for CT
    Kalra, MK
    Maher, MM
    Toth, TL
    Schmidt, B
    Westerman, BL
    Morgan, HT
    Saini, S
    RADIOLOGY, 2004, 233 (03) : 649 - 657
  • [8] Size-based protocol optimization using automatic tube current modulation and automatic kV selection in computed tomography
    MacDougall, Robert D.
    Kleinman, Patricia L.
    Callahan, Michael J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 328 - 341
  • [9] Risk-minimizing tube current modulation for computed tomography
    Kachelriess, Marc
    RADIOLOGIE, 2023, 63 (07): : 523 - 529
  • [10] Design and use of a phantom for testing and comparing the performance of computed tomography automatic tube current modulation systems
    Sookpeng, S.
    Martin, C. J.
    Krisanachinda, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (03) : 753 - 773