Dosimetric changes with computed tomography automatic tube-current modulation techniques

被引:10
|
作者
Spampinato S. [1 ,2 ,4 ]
Gueli A.M. [1 ,2 ]
Milone P. [2 ,3 ]
Raffaele L.A. [1 ,2 ,3 ]
机构
[1] PH3DRA Laboratories (PHysics for Dating Diagnostic Dosimetry Research and Applications), Dipartimento di Fisica e Astronomia, Università di Catania and INFN-Catania, Via Santa Sofia 64, Catania
[2] Scuola di Specializzazione in Fisica Medica, Dipartimento di Scienze mediche chirurgiche e tecnologie avanzate “G. F. Ingrassia”, Scuola Facoltà di Medicina, Via Santa Sofia 78, Catania
[3] Unità Operativa Complessa di Radiodiagnostica e Radioterapia, Azienda Ospedaliero-Universitaria Policlinico di Catania, P. O. Gaspare Rodolico, Via Santa Sofia 78, Catania
[4] Department of Oncology, Aarhus University Hospital, Nørrebrogade 44, Aarhus
关键词
Anthropomorphic phantom; CTDI; DLP; Noise index; Radiochromic films;
D O I
10.1007/s12194-018-0454-5
中图分类号
学科分类号
摘要
The study is aimed at a verification of dose changes for a computed tomography automatic tube-current modulation (ATCM) technique. For this purpose, anthropomorphic phantom and Gafchromic® XR-QA2 films were used. Radiochromic films were cut according to the shape of two thorax regions. The ATCM algorithm is based on noise index (NI) and three exam protocols with different NI were chosen, of which one was a reference. Results were compared with dose values displayed by the console and with Poisson statistics. The information obtained with radiochromic films has been normalized with respect to the NI reference value to compare dose percentage variations. Results showed that, on average, the information reported by the CT console and calculated values coincide with measurements. The study allowed verification of the dose information reported by the CT console for an ATCM technique. Although this evaluation represents an estimate, the method can be a starting point for further studies. © 2018, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:184 / 191
页数:7
相关论文
共 50 条
  • [21] Assessment of an organ-based tube current modulation in thoracic computed tomography
    Matsubara, Kosuke
    Sugai, Mai
    Toyoda, Asami
    Koshida, Haruka
    Sakuta, Keita
    Takata, Tadanori
    Koshida, Kichiro
    Iida, Hiroji
    Matsui, Osamu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (02): : 148 - 158
  • [22] Use of Automatic Tube Current Modulation With a Standardized Noise Index in Young Children Undergoing Chest Computed Tomography Scans With 64-Slice Multidetector Computed Tomography
    Peng, Yun
    Li, Jianying
    Ma, Daqing
    Zhang, Qifeng
    Liu, Yue
    Zeng, Jinjin
    Sun, Guoqiang
    ACTA RADIOLOGICA, 2009, 50 (10) : 1175 - 1181
  • [23] Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis
    Rizzo, S
    Kalra, M
    Schmidt, B
    Dalal, T
    Suess, C
    Flohr, T
    Blake, M
    Saini, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) : 673 - 679
  • [24] Dose study of electrocardiogram automatic tube current modulation technology in prospective coronary computed tomography angiography scans of overweight patients
    He, Guiru
    Liu, Xiaopei
    Liu, Yan
    Wang, Wei
    Ke, Zhiliang
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 9 (06) : 2384 - 2388
  • [25] Online Angular Tube Current Modulation in X-Ray Computed Tomography: Can Tube Current Be Modulated Appropriately?
    Matsubara, K.
    Koshida, H.
    Takata, T.
    Horii, J.
    Iida, H.
    Koshida, K.
    Matsui, O.
    Fukuda, A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3619 - 3619
  • [26] The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study
    Wang, Qian
    Zhao, Xinming
    Song, Junfeng
    Guo, Ning
    Zhu, Ying
    Liu, Jianxin
    Qi, Weiwei
    Wu, Jing
    Liang, Yuan
    Feng, Shichao
    Hu, Mancang
    Zhou, Chunwu
    Wang, Xiaoying
    Hong, Nan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (04) : 453 - 464
  • [27] Pediatric multidetector computed tomography using tube current modulation and a patient image gallery
    Honnef, D.
    Mahnken, A. H.
    Haras, G.
    Wildberger, J. E.
    Staatz, G.
    Barker, M. Das M.
    Stanzel, S.
    Nther, R. W. Gu
    Hohl, C.
    ACTA RADIOLOGICA, 2008, 49 (04) : 475 - 483
  • [28] Effects of scout radiographic imaging conditions on tube current modulation in chest computed tomography
    Inoue, Yusuke
    Itoh, Hiroyasu
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (01) : 253 - 269
  • [29] Signal-to-noise ratio and dose to the lens of the eye for computed tomography examination of the brain using an automatic tube current modulation system
    Sookpeng S.
    Butdee C.
    Emergency Radiology, 2017, 24 (3) : 233 - 239
  • [30] Do metallic endoprostheses increase radiation dose associated with automatic tube-current modulation in abdominal-pelvic MDCT? A phantom and patient study
    Rizzo, SMR
    Kalra, MK
    Maher, MM
    Blake, MA
    Toth, TL
    Saini, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 491 - 496