Risk-minimizing tube current modulation for computed tomography

被引:0
|
作者
Kachelriess, Marc [1 ]
机构
[1] Deutsch Krebsforschungszentrum DFKZ, Abt Rontgenbildgebung & Computertomog, Heidelberg, Germany
来源
RADIOLOGIE | 2023年 / 63卷 / 07期
关键词
Radiation exposure; Tube current-time product; Dose reduction; Imaging quality; Deep learning; ONLINE MODULATION; DOSE REDUCTION; CT;
D O I
10.1007/s00117-023-01160-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim/Problem: Every computed tomography (CT) examination is accompanied by radiation exposure. The aim is to reduce this as much as possible without compromising image quality by using a tube current modulation technique.Standard procedure: CT tube current modulation (TCM), which has been in use for about two decades, adjusts the tube current to the patient's attenuation (in the angular and z-directions) in a way that minimizes the mAs product (tube current-time product) of the scan without compromising image quality. This mAsTCM, present in all CT devices, is associated with a significant dose reduction in those anatomical areas that have high attenuation differences between anterior-posterior (a.p.) and lateral, particularly the shoulder and pelvis. Radiation risk of individual organs or of the patient is not considered in mAsTCM.Methodological innovation: Recently, a TCM method was proposed that directly minimizes the patient's radiation risk by predicting organ dose levels and taking them into account when choosing tube current. It is shown that this so-called riskTCM is significantly superior to mAsTCM in all body regions. To be able to use riskTCM in clinical routine, only a software adaptation of the CT system would be necessary.Conclusions: With riskTCM, significant dose reductions can be achieved compared to the standard procedure, typically around 10%-30%. This is especially true in those body regions where the standard procedure shows only moderate advantages over a scan without any tube current modulation at all. It is now up to the CT vendors to take action and implement riskTCM.
引用
收藏
页码:523 / 529
页数:7
相关论文
共 50 条
  • [1] Risikominimierende Röhrenstrommodulation in der ComputertomographieRisk-minimizing tube current modulation for computed tomography
    Marc Kachelrieß
    Die Radiologie, 2023, 63 (7) : 523 - 529
  • [2] Considerations on an automatic computed tomography tube current modulation system
    Moro, Luca
    Panizza, Denis
    D'Ambrosio, Daniela
    Carne, Irene
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (04) : 525 - 530
  • [3] Setting up computed tomography automatic tube current modulation systems
    Martin, C. J.
    Sookpeng, S.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (03) : R74 - R95
  • [4] A risk-minimizing model under uncertainty in portfolio
    Yoshida, Yuji
    FOUNDATIONS OF FUZZY LOGIC AND SOFT COMPUTING, PROCEEDINGS, 2007, 4529 : 381 - 391
  • [5] A Risk-Minimizing Portfolio Model with Fuzziness
    Yoshida, Yuji
    2008 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS, VOLS 1-5, 2008, : 909 - 914
  • [6] Evaluation of Tube Current Modulation Programs for the Optimization of Chest Computed Tomography Protocols
    Chipiga, L. A.
    Vodovatov, A. V.
    Grigorieva, T., V
    Ivanova, L. A.
    6TH INTERNATIONAL CONFERENCE ON X-RAY, ELECTROVACUUM AND BIOMEDICAL TECHNIQUE, 2020, 2250
  • [7] Dosimetric changes with computed tomography automatic tube-current modulation techniques
    Spampinato S.
    Gueli A.M.
    Milone P.
    Raffaele L.A.
    Radiological Physics and Technology, 2018, 11 (2) : 184 - 191
  • [8] Assessment of an organ-based tube current modulation in thoracic computed tomography
    Matsubara, Kosuke
    Sugai, Mai
    Toyoda, Asami
    Koshida, Haruka
    Sakuta, Keita
    Takata, Tadanori
    Koshida, Kichiro
    Iida, Hiroji
    Matsui, Osamu
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (02): : 148 - 158
  • [9] Online Angular Tube Current Modulation in X-Ray Computed Tomography: Can Tube Current Be Modulated Appropriately?
    Matsubara, K.
    Koshida, H.
    Takata, T.
    Horii, J.
    Iida, H.
    Koshida, K.
    Matsui, O.
    Fukuda, A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3619 - 3619
  • [10] RISK-MINIMIZING REINSURANCE PROTECTION FOR MULTIVARIATE RISKS
    Cheung, K. C.
    Sung, K. C. J.
    Yam, S. C. P.
    JOURNAL OF RISK AND INSURANCE, 2014, 81 (01) : 219 - 236