Risk-minimizing tube current modulation for computed tomography

被引:0
|
作者
Kachelriess, Marc [1 ]
机构
[1] Deutsch Krebsforschungszentrum DFKZ, Abt Rontgenbildgebung & Computertomog, Heidelberg, Germany
来源
RADIOLOGIE | 2023年 / 63卷 / 07期
关键词
Radiation exposure; Tube current-time product; Dose reduction; Imaging quality; Deep learning; ONLINE MODULATION; DOSE REDUCTION; CT;
D O I
10.1007/s00117-023-01160-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim/Problem: Every computed tomography (CT) examination is accompanied by radiation exposure. The aim is to reduce this as much as possible without compromising image quality by using a tube current modulation technique.Standard procedure: CT tube current modulation (TCM), which has been in use for about two decades, adjusts the tube current to the patient's attenuation (in the angular and z-directions) in a way that minimizes the mAs product (tube current-time product) of the scan without compromising image quality. This mAsTCM, present in all CT devices, is associated with a significant dose reduction in those anatomical areas that have high attenuation differences between anterior-posterior (a.p.) and lateral, particularly the shoulder and pelvis. Radiation risk of individual organs or of the patient is not considered in mAsTCM.Methodological innovation: Recently, a TCM method was proposed that directly minimizes the patient's radiation risk by predicting organ dose levels and taking them into account when choosing tube current. It is shown that this so-called riskTCM is significantly superior to mAsTCM in all body regions. To be able to use riskTCM in clinical routine, only a software adaptation of the CT system would be necessary.Conclusions: With riskTCM, significant dose reductions can be achieved compared to the standard procedure, typically around 10%-30%. This is especially true in those body regions where the standard procedure shows only moderate advantages over a scan without any tube current modulation at all. It is now up to the CT vendors to take action and implement riskTCM.
引用
收藏
页码:523 / 529
页数:7
相关论文
共 50 条
  • [21] Locally Risk-Minimizing Hedging of Counterparty Risk for Portfolio of Credit Derivatives
    Bo, Lijun
    Ceci, Claudia
    APPLIED MATHEMATICS AND OPTIMIZATION, 2020, 82 (02): : 799 - 850
  • [22] Locally Risk-Minimizing Hedging of Counterparty Risk for Portfolio of Credit Derivatives
    Lijun Bo
    Claudia Ceci
    Applied Mathematics & Optimization, 2020, 82 : 799 - 850
  • [23] Design and use of a phantom for testing and comparing the performance of computed tomography automatic tube current modulation systems
    Sookpeng, S.
    Martin, C. J.
    Krisanachinda, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (03) : 753 - 773
  • [24] Impact of tube current modulation on lesion conspicuity index in Hi-Resolution Chest Computed Tomography
    Szczepura, Katy
    Tomkinson, David
    Manning, David
    MEDICAL IMAGING 2017: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2017, 10136
  • [25] Organ-based tube current modulation and bismuth eye shielding in pediatric head computed tomography
    Stefan Markart
    Tim S. Fischer
    Simon Wildermuth
    Tobias J. Dietrich
    Hatem Alkadhi
    Sebastian Leschka
    Sabine Guesewell
    Michael R. Ditchfield
    Ismail Oezden
    Gerd Lutters
    Stephan L. Waelti
    Pediatric Radiology, 2022, 52 : 2584 - 2594
  • [26] Design and use of a phantom for testing and comparing the performance of computed tomography automatic tube current modulation systems
    Sookpeng, S.
    Martin, C.J.
    Krisanachinda, A.
    Sookpeng, S. (supawitoos@nu.ac.th), 1600, Institute of Physics Publishing (40): : 753 - 773
  • [27] Improving linac integrated cone beam computed tomography image quality using tube current modulation
    Stankovic, Uros
    Ploeger, Lennert S.
    Sonke, Jan-Jakob
    MEDICAL PHYSICS, 2021, 48 (04) : 1739 - 1749
  • [28] Organ-based tube current modulation and bismuth eye shielding in pediatric head computed tomography
    Markart, Stefan
    Fischer, Tim S.
    Wildermuth, Simon
    Dietrich, Tobias J.
    Alkadhi, Hatem
    Leschka, Sebastian
    Guesewell, Sabine
    Ditchfield, Michael R.
    Oezden, Ismail
    Lutters, Gerd
    Waelti, Stephan L.
    PEDIATRIC RADIOLOGY, 2022, 52 (13) : 2584 - 2594
  • [29] Risk-minimizing approach to bid-cutting limit determination
    Chao, Li-Chung
    Liou, Chang-Nan
    CONSTRUCTION MANAGEMENT AND ECONOMICS, 2007, 25 (08) : 835 - 843
  • [30] Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography A Phantom Study on Radiation Dose and Image Quality
    Papadalds, Antonios E.
    Damilakis, John
    INVESTIGATIVE RADIOLOGY, 2019, 54 (05) : 265 - 272