Dual-energy CT and ceramic or titanium prostheses material reduce CT artifacts and provide superior image quality of total knee arthroplasty

被引:0
|
作者
Maximilian F. Kasparek
Michael Töpker
Mathias Lazar
Michael Weber
Michael Kasparek
Thomas Mang
Paul Apfaltrer
Bernd Kubista
Reinhard Windhager
Helmut Ringl
机构
[1] Medical University of Vienna,Department of Orthopaedics and Trauma Surgery, Vienna General Hospital
[2] Medical University of Vienna,Department of Biomedical Imaging and Image
[3] Orthopaedic Hospital Speising,Guided Therapy
关键词
Total knee arthroplasty; Single-energy CT; Dual-energy CT; Blooming artifacts; Streak artifacts; Mono-energetic imaging;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1552 / 1561
页数:9
相关论文
共 50 条
  • [31] IMAGE-DOMAIN MATERIAL DECOMPOSITION USING AN ITERATIVE NEURAL NETWORK FOR DUAL-ENERGY CT
    Li, Zhipeng
    Chun, Il Yong
    Long, Yong
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 651 - 655
  • [32] Comparison of image and data domain methods for three-material decomposition in dual-energy CT
    Humphries, T.
    McGarity, R.
    Uy, K.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [33] Image quality optimization and evaluation of linearly mixed images in dual-source, dual-energy CT
    Yu, Lifeng
    Primak, Andrew N.
    Liu, Xin
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2009, 36 (03) : 1019 - 1024
  • [34] Split-bolus CT-urography using dual-energy CT: Feasibility, image quality and dose reduction
    Takeuchi, Mitsuru
    Kawai, Tatsuya
    Ito, Masato
    Ogawa, Masaki
    Ohashi, Kazuya
    Hara, Masaki
    Shibamoto, Yuta
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3160 - 3165
  • [35] Dual-Source Dual-Energy CT Portal Venous Phase Abdominal CT Scans in Large Body Habitus Patients: Preliminary Observations on Image Quality and Material Decomposition
    Baliyan, Vinit
    Kordbacheh, Hamed
    Serrao, Jessica
    Sahani, Dushyant V.
    Kambadakone, Avinash R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 932 - 936
  • [36] The potential of iodinated contrast reduction in dual-energy CT thoracic angiography; an evaluation of image quality
    Johansen, C. B.
    Martinsen, A. C. T.
    Enden, T. R.
    Svanteson, M.
    RADIOGRAPHY, 2022, 28 (01) : 2 - 7
  • [37] Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT
    Bauer, Ralf W.
    Kramer, Sebastian
    Renker, Matthias
    Schell, Boris
    Larson, Maya Christina
    Beeres, Martin
    Lehnert, Thomas
    Jacobi, Volkmar
    Vogl, Thomas J.
    Kerl, Josef Matthias
    EUROPEAN RADIOLOGY, 2011, 21 (10) : 2139 - 2147
  • [38] Image quality improvement in head and neck angiography based on dual-energy CT and deep learning
    He Zhang
    Lulu Zhang
    Juan Long
    He Zhang
    Xiaonan Sun
    Shuai Zhang
    Aiyun Sun
    Shenman Qiu
    Yankai Meng
    Tao Ding
    Chunfeng Hu
    Kai Xu
    BMC Medical Imaging, 25 (1)
  • [39] The pilot study of dual-energy CT gemstone spectral imaging on the image quality of hand tendons
    Deng, Kai
    Li, Wei
    Wang, Jun-jun
    Wang, Guang-li
    Shi, Hao
    Zhang, Cheng-qi
    CLINICAL IMAGING, 2013, 37 (05) : 930 - 933
  • [40] Comparison of Image Quality and Radiation Dose Between Single-Energy and Dual-Energy Images for the Brain With Stereotactic Frames on Dual-Energy Cerebral CT
    Zhao, Xiaojing
    Chao, Wang
    Shan, Yi
    Li, Jingkai
    Zhao, Cheng
    Zhang, Miao
    Lu, Jie
    FRONTIERS IN RADIOLOGY, 2022, 2