Split-bolus CT-urography using dual-energy CT: Feasibility, image quality and dose reduction

被引:36
|
作者
Takeuchi, Mitsuru [1 ]
Kawai, Tatsuya [1 ]
Ito, Masato [1 ]
Ogawa, Masaki [1 ]
Ohashi, Kazuya [2 ]
Hara, Masaki [1 ]
Shibamoto, Yuta [1 ]
机构
[1] Nagoya City Univ, Grad Sch Med Sci, Dept Radiol, Mizuho Ku, Nagoya, Aichi 4678601, Japan
[2] Nagoya City Univ Hosp, Dept Radiol, Mizuho Ku, Nagoya, Aichi 4678601, Japan
关键词
Dual energy CT; CT urography; Virtual non-enhanced image; Radiation dose reduction; COMPUTED-TOMOGRAPHY; COLLECTING SYSTEM; MDCT UROGRAPHY; URINARY STONES; CONTRAST; OPTIMIZATION; ENHANCEMENT; PERFORMANCE; HEMATURIA; PHANTOM;
D O I
10.1016/j.ejrad.2012.05.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively evaluate the feasibility of dual-energy (DE) split-bolus CT-urography (CTU) and the quality of virtual non-enhanced images (VNEI) and DE combined nephrographic-excretory phase images (CNEPI), and to estimate radiation dose reduction if true non-enhanced images (TNEI) could be omitted. Patients and methods: Between August and September 2011, 30 consecutive patients with confirmed or suspected urothelial cancer or with hematuria underwent DE CT. Single-energy TNEI and DE CNEPI were obtained. VNEI was reconstructed from CNEPI. Image quality of CNEPI and VNEI was evaluated using a 5-point scale. The attenuation of urine in the bladder on TNEI and VNEI was measured. The CT dose index volume (CTDI (vol)) of the two scans was recorded. Results: The mean image quality score of CNEPI and VNEI was 4.7 and 3.3, respectively. The mean differences in urine attenuation between VNEI and TNEI were 14 +/- 15 [SD] and -16 +/- 29 in the anterior and posterior parts of the bladder, respectively. The mean CTDI (vol) for TNEI and CNEPI was 11.8 and 10.9 mGy, respectively. Omission of TNEI could reduce the total radiation dose by 52%. Conclusion: DE split-bolus CTU is technically feasible and can reduce radiation exposure; however, an additional TNEI scan is necessary when the VNEI quality is poor or quantitative evaluation of urine attenuation is required. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:3160 / 3165
页数:6
相关论文
共 50 条
  • [1] Split-Bolus Portal Venous Phase Dual-Energy CT Urography: Protocol Design, Image Quality, and Dose Reduction
    Chen, Chiao-Yun
    Hsu, Jui-Sheng
    Jaw, Twei-Shiun
    Shih, Ming-Chen Paul
    Lee, Lo-Jeh
    Tsai, Tzu-Hsueh
    Liu, Gin-Chung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : W492 - W501
  • [2] Diagnostic Performance of Split-Bolus Portal Venous Phase Dual-Energy CT Urography in Patients With Hematuria
    Chen, Chiao-Yun
    Tsai, Tzu-Hsueh
    Jaw, Twei-Shiun
    Lai, Ming-Lai
    Chao, Min-Fang
    Liu, Gin-Chung
    Hsu, Jui-Sheng
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (05) : 1013 - 1022
  • [3] Split-bolus dual-energy CT urography: protocol optimization and diagnostic performance for the detection of urinary stones
    Christoph A. Karlo
    Ralph Gnannt
    Anna Winklehner
    Michael A. Fischer
    Olivio F. Donati
    Daniel Eberli
    Tullio Sulser
    Hatem Alkadhi
    Paul Stolzmann
    Abdominal Imaging, 2013, 38 : 1136 - 1143
  • [4] Split-bolus dual-energy CT urography: protocol optimization and diagnostic performance for the detection of urinary stones
    Karlo, Christoph A.
    Gnannt, Ralph
    Winklehner, Anna
    Fischer, Michael A.
    Donati, Olivio F.
    Eberli, Daniel
    Sulser, Tullio
    Alkadhi, Hatem
    Stolzmann, Paul
    ABDOMINAL IMAGING, 2013, 38 (05): : 1136 - 1143
  • [5] CT of the kidneys in potential living kidney donors: using split-bolus technique for dose reduction
    Sulkowska, K.
    Palczewski, P.
    Sawicka, M.
    Jakimowicz, T.
    Alsharabi, A.
    Nazarewski, S.
    Kieszek, R.
    Lewandowska, D.
    Kwiatkowski, A.
    Golebiowski, M.
    ACTA RADIOLOGICA, 2017, 58 : 22 - 22
  • [6] Split-bolus CT urography after microwave ablation of renal cell carcinoma improves image quality and reduces radiation exposure
    Tannenbaum, Alex P.
    Lubner, Meghan G.
    Mithqal, Ayman
    Ziemlewicz, Timothy J.
    Allen, Glenn O.
    Brace, Christopher L.
    Abel, E. Jason
    Mankowski-Gettle, Lori
    Schenkman, Noah S.
    Wells, Shane A.
    ABDOMINAL RADIOLOGY, 2022, 47 (06) : 2230 - 2237
  • [7] Split-bolus CT urography after microwave ablation of renal cell carcinoma improves image quality and reduces radiation exposure
    Alex P. Tannenbaum
    Meghan G. Lubner
    Ayman Mithqal
    Timothy J. Ziemlewicz
    Glenn O. Allen
    Christopher L. Brace
    E. Jason Abel
    Lori Mankowski-Gettle
    Noah S. Schenkman
    Shane A. Wells
    Abdominal Radiology, 2022, 47 : 2230 - 2237
  • [8] Application value of split-bolus contrast injection combined with dual-energy CT scanning technology in pediatric CTU imaging
    Chen, Hongqiao
    Deng, Zhikai
    Tan, Ting
    Li, Siwei
    Qian, Fangfang
    He, Ling
    Tang, Shilong
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 184
  • [9] Dual-Energy CT Urography With 50% Reduced Iodine Dose Versus Single-Energy CT Urography With Standard Iodine Dose
    Shuman, William P.
    Mileto, Achille
    Busey, Janet M.
    Desai, Nitin
    Koprowicz, Kent M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (01) : 117 - 123
  • [10] Evaluation of image quality and radiation dose of abdominal dual-energy CT
    Schmidt, David
    Soderberg, Marcus
    Nilsson, Mats
    Lindvall, Hakan
    Christoffersen, Christina
    Leander, Peter
    ACTA RADIOLOGICA, 2018, 59 (07) : 845 - 852