Measurement of Prostate Volume with MRI (A Guide for the Perplexed): Biproximate Method with Analysis of Precision and Accuracy

被引:0
|
作者
Neil F. Wasserman
Eric Niendorf
Benjamin Spilseth
机构
[1] University of Minnesota,Department of Radiology
[2] Mayo Mail Code 292,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
To review the anatomic basis of prostate boundary selection on T2-weighted magnetic resonance imaging (MRI). To introduce an alternative 3D ellipsoid measuring technique that maximizes precision, report the intra- and inter-observer reliability, and to advocate it’s use for research involving multiple observers. We demonstrate prostate boundary anatomy using gross pathology and MRI examples. This provides background for selecting key boundary marks when measuring prostate volume. An alternative ellipsoid volume method is then proposed using these boundaries in an attempt to improve inter-observer precision. An IRB approved retrospective study of 140 patients with elevated serum prostate specific antigen levels and/or abnormal digital rectal examinations was done with T2-weighted MRI applying a new (Biproximate) technique. Measurements were made by 2 examiners, correlated with each other for inter-observer precision and correlated with an expert observer for accuracy. Correlation statistics, linear regression analysis, and tests of means were applied using p ≤ 0.05 as the threshold for significance. Inter-observer correlation (precision) was 0.95 between observers. Correlation between these observers and the expert (accuracy) was 0.94 and 0.97 respectively. Intra-observer correlation for the expert was 0.98. Means for inter-rater reliability and accuracy were all the same (p = 0.001). We conclude that using more precise reproducible landmarks with biproximate technique, precision and accuracy of total prostate volume is found to be demonstrated.
引用
收藏
相关论文
共 50 条
  • [21] The effect of different inflating volume on the measurement accuracy of the modified cuff pressure measurement method
    Lijun Xiang
    Meng Cao
    Xuemei Song
    Miaoqin Tan
    Taosheng Deng
    Yuan Wang
    Xiaomei Zhang
    Journal of Clinical Monitoring and Computing, 2022, 36 : 521 - 528
  • [22] The effect of different inflating volume on the measurement accuracy of the modified cuff pressure measurement method
    Xiang, Lijun
    Cao, Meng
    Song, Xuemei
    Tan, Miaoqin
    Deng, Taosheng
    Wang, Yuan
    Zhang, Xiaomei
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (02) : 521 - 528
  • [23] Analysis of the accuracy for straightness measurement with EST method
    Wang, Xianping
    Li, Shengyi
    Guofang Keji Daxue Xuebao/Journal of National University of Defense Technology, 2000, 22 (03): : 100 - 104
  • [24] An analysis of the accuracy for straightness measurement with EST method
    Wang, XP
    Li, SY
    PROCEEDINGS OF THE FIRST INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, 1999, : 125 - 129
  • [25] Accuracy of Multiparametric MRI for Prostate Cancer Detection: A Meta-Analysis
    de Rooij, Maarten
    Hamoen, Esther H. J.
    Futterer, Jurgen J.
    Barentsz, Jelle O.
    Rovers, Maroeska M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (02) : 343 - 351
  • [26] ACCURACY OF VOLUME MEASUREMENT OF RABBIT LEFT-VENTRICLE BY BALLOON METHOD
    GOTO, Y
    SLINKER, BK
    LEWINTER, MM
    AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (02): : H394 - H396
  • [27] A fuzzy expert system to increase accuracy and precision in measurement system analysis
    Hajipour, Vahid
    Kazemi, Abolfazl
    Mousavi, Seyed Mohsen
    MEASUREMENT, 2013, 46 (08) : 2770 - 2780
  • [28] Precision and Accuracy Measurement of Radiostereometric Analysis Applied to Movement of the Sacroiliac Joint
    Kibsgard, Thomas J.
    Roise, Olav
    Stuge, Britt
    Roehrl, Stephan M.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (11) : 3187 - 3194
  • [29] Accuracy analysis of the control volume method in heat conduction
    Ninic, N
    Jurjevic, D
    STROJARSTVO, 2004, 46 (1-3): : 25 - 38
  • [30] Using the differential method of measurement to control the accuracy of precision angle measuring structures
    Kiryanov V.P.
    Kiryanov A.V.
    Chukanov V.V.
    Optoelectronics, Instrumentation and Data Processing, 2016, 52 (4) : 354 - 359