Measurement of Prostate Volume with MRI (A Guide for the Perplexed): Biproximate Method with Analysis of Precision and Accuracy

被引:0
|
作者
Neil F. Wasserman
Eric Niendorf
Benjamin Spilseth
机构
[1] University of Minnesota,Department of Radiology
[2] Mayo Mail Code 292,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
To review the anatomic basis of prostate boundary selection on T2-weighted magnetic resonance imaging (MRI). To introduce an alternative 3D ellipsoid measuring technique that maximizes precision, report the intra- and inter-observer reliability, and to advocate it’s use for research involving multiple observers. We demonstrate prostate boundary anatomy using gross pathology and MRI examples. This provides background for selecting key boundary marks when measuring prostate volume. An alternative ellipsoid volume method is then proposed using these boundaries in an attempt to improve inter-observer precision. An IRB approved retrospective study of 140 patients with elevated serum prostate specific antigen levels and/or abnormal digital rectal examinations was done with T2-weighted MRI applying a new (Biproximate) technique. Measurements were made by 2 examiners, correlated with each other for inter-observer precision and correlated with an expert observer for accuracy. Correlation statistics, linear regression analysis, and tests of means were applied using p ≤ 0.05 as the threshold for significance. Inter-observer correlation (precision) was 0.95 between observers. Correlation between these observers and the expert (accuracy) was 0.94 and 0.97 respectively. Intra-observer correlation for the expert was 0.98. Means for inter-rater reliability and accuracy were all the same (p = 0.001). We conclude that using more precise reproducible landmarks with biproximate technique, precision and accuracy of total prostate volume is found to be demonstrated.
引用
收藏
相关论文
共 50 条
  • [31] A practical guide to analytical method validation, including measurement uncertainty and accuracy profiles
    Gustavo Gonzalez, A.
    Angeles Herrador, M.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (03) : 227 - 238
  • [32] Measurement method and scheme verification for the slider profile accuracy of a linear rolling guide
    Du K.
    Ou Y.
    Feng H.
    Rong Q.
    Ou, Yi, 1600, Chinese Vibration Engineering Society (36): : 238 - 247
  • [33] ANALYSIS OF COMPENSATION METHOD FOR PRECISION MEASUREMENT OF ISOTOPIC ABUNDANCES
    USTINOV, VI
    GRINENKO, VA
    INDUSTRIAL LABORATORY, 1964, 30 (05): : 722 - &
  • [34] ACCURACY OF A VOLUME FRACTION MEASUREMENT USING AREAL IMAGE-ANALYSIS
    SHI, DX
    WINSLOW, D
    JOURNAL OF TESTING AND EVALUATION, 1991, 19 (03) : 210 - 213
  • [35] The Coordinate Transformation Method and Accuracy Analysis in GPS Measurement
    Yuan, Debao
    Cui, Xi-min
    Wang, Sheng-yao
    Qiu, Ya-hui
    Wang, Guo
    Jin, Jing-jing
    2011 INTERNATIONAL CONFERENCE OF ENVIRONMENTAL SCIENCE AND ENGINEERING, VOL 12, PT A, 2012, 12 : 232 - 237
  • [36] A RACE-STRATIFIED ANALYSIS OF THE ACCURACY OF PROSTATE MRI IN BIOPSY NAIVE MEN
    Meza, Julio
    Babajide, Rilwan
    Saoud, Ragheed
    Abelleria, Josephine
    Helenowski, Irene
    Murphy, Adam
    Horowitz, Jeanne
    Casalino, David
    JOURNAL OF UROLOGY, 2022, 207 (05): : E962 - E962
  • [37] Prostate Volume Estimation on MRI: Accuracy and Effects of Ellipsoid and Bullet-Shaped Measurements on PSA Density
    Stanzione, Arnaldo
    Ponsiglione, Andrea
    Di Fiore, Gianluca Armando
    Picchi, Stefano Giusto
    Di Stasi, Martina
    Verde, Francesco
    Petretta, Mario
    Imbriaco, Massimo
    Cuocolo, Renato
    ACADEMIC RADIOLOGY, 2021, 28 (08) : E219 - E226
  • [38] Accuracy of carboxyhe-moglobin dilution method for the measurement of circulating blood volume
    Satoshi Ohki
    Fumio Kunimoto
    Yukitaka Isa
    Hideaki Obata
    Susumu Ishikawa
    Tetsuya Koyano
    Noboru Oriuchi
    Fumio Goto
    Yasuo Morishita
    Canadian Journal of Anaesthesia, 2000, 47 : 150 - 154
  • [39] ACCURACY OF VENTRICULAR LUMEN VOLUME MEASUREMENT BY INTRA-VENTRICULAR BALLOON METHOD
    SUGA, H
    SAGAWA, K
    AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 236 (03): : H506 - H507
  • [40] Accuracy and precision of a new portable ultrasound scanner, the Biocon-700, in residual urine volume measurement
    Moon Kyoung Cho
    Eun Ji Noh
    Chul Hong Kim
    International Urogynecology Journal, 2017, 28 : 1057 - 1061