Photon beam softening coefficient determination with slab thickness in small filed size: Monte Carlo study

被引:9
|
作者
Bencheikh M. [1 ]
Maghnouj A. [1 ]
Tajmouati J. [1 ]
机构
[1] LISTA Laboratory, Physics Department, Faculty of Sciences Dhar El-Mahraz, University of Sidi Mohamed Ben Abdellah, Fez
关键词
BEAMDP code; BEAMnrc code; Monte Carlo simulation; Photon beam softening; Slab thickness;
D O I
10.1134/S1547477117060085
中图分类号
学科分类号
摘要
Determination and understanding of photon beam softening using material soften photon beam for clinical usage is important for material study for attenuation and for beam modifier enhancements and linac improvements. Monte Carlo model was used to simulate 6 MeV photon beams produced by Varian Clinac 2100 accelerator with flattening filter thereafter the flattening filter was replaced by a slab of aluminum and copper with different of 0.5, 1, 1.5 and 2 mm. The Monte Carlo geometry was validated by a gamma index acceptance rate of 99% in PDD and 98% in dose profiles, the gamma criteria was 3% for dose difference and 3mm for distance to agreement. The purpose was to investigate the beam softening for small size and beam attenuation as a function of inserted slab thickness of copper and aluminum and also as a function of off-axis distance. For beam softening evaluation, variation amplitude of beam softening coefficient a1 was very high near the beam central axis and decreased with off-axis distance and also it was high for aluminum slab compared to copper slab. For aluminum slab, variation amplitude of beam softening coefficient a1 have a minimum at–0.5 cm–1 and a maximum at 0.5 cm–1 and for copper slab, variation amplitude of beam softening a1 have a minimum at–0.15 cm–1 and a maximum at 0.11 cm–1. Variation amplitude of beam softening coefficient a2 was very high near the beam central axis and decreased with off-axis distance and it was very high for aluminum slab compared to copper slab. For aluminum slab, variation amplitude of beam softening coefficient a2 have a minimum at–0.54 cm–2 and a maximum at 0.44 cm–2 and for copper slab, variation amplitude of beam softening coefficient a2 have a minimum at–0.111 cm–2 and a maximum at 0.0825 cm–2. © 2017, Pleiades Publishing, Ltd.
引用
收藏
页码:963 / 970
页数:7
相关论文
共 50 条
  • [41] Focal source size measurement for Monte Carlo simulations of percentage depth doses in very small photon fields
    Sham, E.
    Devic, S.
    Seuntjens, J.
    Podgorsak, E.
    MEDICAL PHYSICS, 2006, 33 (06) : 2284 - 2284
  • [42] Benchmarking of Monte Carlo model of Siemens Oncor® linear accelerator for 18 MV photon beam: Determination of initial electron beam parameters
    Najafzadeh, Milad
    Hoseini-Ghafarokhi, Mojtaba
    Bolagh, Rezgar Shahi Mayn
    Haghparast, Mohammad
    Zarifi, Shiva
    Nickfarjam, Abolfazl
    Farhood, Bagher
    Chow, James C. L.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (06) : 1047 - 1070
  • [43] Photon Dose Calculation Method Based on Monte Carlo Finite-Size Pencil Beam Model in Accurate Radiotherapy
    Zheng, Huaqing
    Sun, Guangyao
    Li, Gui
    Cao, Ruifen
    Pei, Xi
    Hu, Liqin
    Song, Gang
    Wu, Yican
    COMMUNICATIONS IN COMPUTATIONAL PHYSICS, 2013, 14 (05) : 1415 - 1422
  • [44] Monte Carlo study of the finite-size effects on the magnetization of maghemite small particles
    Iglesias, O
    Labarta, A
    Ritort, F
    JOURNAL OF APPLIED PHYSICS, 2001, 89 (11) : 7597 - 7599
  • [45] PHOTON BEAM CHARACTERISTICS AT MONITOR CHAMBER LEVEL IN A FLATTENING FILTER FREE LINAC: A MONTE CARLO STUDY
    Lind, M.
    Knoos, T.
    Ceberg, C.
    Wieslander, E.
    McClean, B.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S57 - S57
  • [46] Monte Carlo study of a free flattening filter to increase surface dose on 12 MV photon beam
    Zeghari, A.
    Saaidi, R.
    El Moursli, R. C.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (02): : 307 - 313
  • [47] STUDY OF THE STERIC PARTITION-COEFFICIENT IN SIZE-EXCLUSION CHROMATOGRAPHY BY MONTE-CARLO SIMULATION
    DEGOULET, C
    BUSNEL, JP
    TASSIN, JF
    POLYMER, 1994, 35 (09) : 1957 - 1962
  • [48] Determination of initial electron parameters by means of Monte Carlo simulations for the Siemens Artiste Linac 6 MV photon beam
    Tugrul, Taylan
    Erogul, Osman
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (04) : 331 - 337
  • [49] DETERMINATION OF AN ELEKTA MEDICAL LINAC INTERNAL WEDGE FACTOR ON THE FILED SIZE. OFF-AXIS AND DEPTH IN ?SYMMETRIC AND ASYMMETRIC FIELDS TO INTRODUCE AN ALGORITHM: A MONTE CARLO STUDY?
    Hejazi, P.
    Hashemi, B.
    Shahriar, M.
    Eivazi, M. T.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S258 - S258
  • [50] Monte Carlo study on mucosal dose in oral and nasal cavity using photon beams with small field
    Chow, James C. L.
    Owrangi, Amir M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2010, 10 (04) : 261 - 271