Benchmarking of Monte Carlo model of Siemens Oncor® linear accelerator for 18 MV photon beam: Determination of initial electron beam parameters

被引:4
|
作者
Najafzadeh, Milad [1 ]
Hoseini-Ghafarokhi, Mojtaba [2 ]
Bolagh, Rezgar Shahi Mayn [3 ]
Haghparast, Mohammad [1 ]
Zarifi, Shiva [4 ]
Nickfarjam, Abolfazl [5 ]
Farhood, Bagher [6 ]
Chow, James C. L. [7 ,8 ]
机构
[1] Hormozgan Univ Med Sci, Fac Med, Dept Radiol, Bandare Abbas, Iran
[2] Kermanshah Univ Med Sci, Sch Med Sci, Dept Radiol & Nucl Med, Kermanshah, Iran
[3] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
[4] Semnan Univ Med Sci, Fac Med, Dept Med Phys, Semnan, Iran
[5] Shahid Sadoughi Univ Med Sci, Fac Med, Dept Med Phys, Yazd, Iran
[6] Kashan Univ Med Sci, Fac Paramed Sci, Dept Med Phys & Radiol, Kashan, Iran
[7] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[8] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON, Canada
关键词
Radiotherapy; Monte Carlo simulation; benchmarking; Siemens Oncor; gamma analysis; DOSE DISTRIBUTIONS; RADIOTHERAPY; SENSITIVITY; SIMULATION; INCIDENT; ENERGY; DISCREPANCIES; FLUENCE; SPECTRA; IMPROVE;
D O I
10.3233/XST-190568
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVE: This study aims to benchmark a Monte Carlo (MC) model of the 18MV photon beam produced by the Siemens Oncor (R) linac using the BEAMnrc and DOSXYZnrc codes. METHODS: By matching the percentage depth doses and beam profiles calculated by MC simulations with measurements, the initial electron beam parameters including electron energy, full width at half maximum (spatial FWHM), and mean angular spread were derived for the 10 x 10 cm(2) and 20 x 20 cm(2) field sizes. The MC model of the 18MV photon beam was then validated against the measurements for different field sizes (5 x 5, 30 x 30 and 40 x 40 cm(2)) by gamma index analysis. RESULTS: The optimum values for electron energy, spatial FWHM and mean angular spread were 14.2MeV, 0.08cm and 0.8 degree, respectively. The MC simulations yielded the comparable measurement results of these optimum parameters. The gamma passing rates (with acceptance criteria of 1%/1 mm) for percentage depth doses were found to be 100% for all field sizes. For cross-line profiles, the gamma passing rates were 100%, 97%, 95%, 96% and 95% for 5 x 5, 10 x 10, 20 x 20, 30 x 30 and 40 x 40 cm(2) field sizes, respectively. CONCLUSIONS: By validation of the MC model of Siemens Oncor (R) linac using various field sizes, it was found that both dose profiles of small and large field sizes were very sensitive to the changes in spatial FWHM and mean angular spread of the primary electron beam from the bending magnet. Hence, it is recommended that both small and large field sizes of the 18MV photon beams should be considered in the Monte Carlo linac modeling.
引用
收藏
页码:1047 / 1070
页数:24
相关论文
共 50 条
  • [1] Determination of initial electron parameters by means of Monte Carlo simulations for the Siemens Artiste Linac 6 MV photon beam
    Tugrul, Taylan
    Erogul, Osman
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (04) : 331 - 337
  • [2] Benchmarking of electron beam parameters based on Monte Carlo linear accelerator simulation
    Zhang, Fan
    Zhou, Mi
    Liu, Jing
    Yue, Lu
    Deng, Lihua
    Xu, Zhijian
    Wang, Gang
    TRANSLATIONAL CANCER RESEARCH, 2020, 9 (02) : 577 - 584
  • [3] Monte Carlo linear accelerator simulation of megavoltage photon beams: Independent determination of initial beam parameters
    Almberg, Sigrun Saur
    Frengen, Jomar
    Kylling, Arve
    Lindmo, Tore
    MEDICAL PHYSICS, 2012, 39 (01) : 40 - 47
  • [4] The necessity of a divergent initial electron beam in the Monte-Carlo model of a linear accelerator
    De Smedt, B
    Reynaert, N
    Coghe, M
    Paelinck, L
    Van Duysse, B
    De Wagter, C
    De Neve, W
    Thierens, H
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S42 - S42
  • [5] GATE Monte Carlo Simulation of a 6 MV SIEMENS OncorTM Linear Accelerator Photon Beam : Feasibility and Preliminary Dosimetric Study
    Benhalouche, S.
    Edel, S.
    Visvikis, D.
    Pradier, O.
    Boussion, N.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [6] Monte Carlo estimation of electron contamination in a 18 MV clinical photon beam
    Allahverdi, M.
    Zabihzadeh, M.
    Ay, M. R.
    Mahdavi, S. R.
    Shahriari, M.
    Mesbahi, A.
    Alijanzadeh, H.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2011, 9 (01): : 15 - 28
  • [7] Monte Carlo Commissioning of 6 MV Photon Beam of Varian Linear Accelerator Installed at INOR
    Bajwa, Saqib
    Gul, Attia
    Ahmed, Shahbaz
    Kakakhel, Muhammad Basim
    2016 INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2016,
  • [8] Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator
    Asghar Mesbahi
    Farshad Seyed Nejad
    Radiation Medicine, 2008, 26 : 331 - 336
  • [9] The influence of field size and off-axis distance on photoneutron spectra of the 18 MV Siemens Oncor linear accelerator beam
    Brkic, Hrvoje
    Ivkovic, Ana
    Kasabasic, Mladen
    Sovilj, Marina Poje
    Jurkovic, Slaven
    Stimac, Damir
    Rubin, Otmar
    Faj, Dario
    RADIATION MEASUREMENTS, 2016, 93 : 28 - 34
  • [10] Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator
    Mesbahi, Asghar
    Nejad, Farshad Seyed
    RADIATION MEDICINE, 2008, 26 (06): : 331 - 336