Benchmarking of Monte Carlo model of Siemens Oncor® linear accelerator for 18 MV photon beam: Determination of initial electron beam parameters

被引:4
|
作者
Najafzadeh, Milad [1 ]
Hoseini-Ghafarokhi, Mojtaba [2 ]
Bolagh, Rezgar Shahi Mayn [3 ]
Haghparast, Mohammad [1 ]
Zarifi, Shiva [4 ]
Nickfarjam, Abolfazl [5 ]
Farhood, Bagher [6 ]
Chow, James C. L. [7 ,8 ]
机构
[1] Hormozgan Univ Med Sci, Fac Med, Dept Radiol, Bandare Abbas, Iran
[2] Kermanshah Univ Med Sci, Sch Med Sci, Dept Radiol & Nucl Med, Kermanshah, Iran
[3] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
[4] Semnan Univ Med Sci, Fac Med, Dept Med Phys, Semnan, Iran
[5] Shahid Sadoughi Univ Med Sci, Fac Med, Dept Med Phys, Yazd, Iran
[6] Kashan Univ Med Sci, Fac Paramed Sci, Dept Med Phys & Radiol, Kashan, Iran
[7] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[8] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON, Canada
关键词
Radiotherapy; Monte Carlo simulation; benchmarking; Siemens Oncor; gamma analysis; DOSE DISTRIBUTIONS; RADIOTHERAPY; SENSITIVITY; SIMULATION; INCIDENT; ENERGY; DISCREPANCIES; FLUENCE; SPECTRA; IMPROVE;
D O I
10.3233/XST-190568
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVE: This study aims to benchmark a Monte Carlo (MC) model of the 18MV photon beam produced by the Siemens Oncor (R) linac using the BEAMnrc and DOSXYZnrc codes. METHODS: By matching the percentage depth doses and beam profiles calculated by MC simulations with measurements, the initial electron beam parameters including electron energy, full width at half maximum (spatial FWHM), and mean angular spread were derived for the 10 x 10 cm(2) and 20 x 20 cm(2) field sizes. The MC model of the 18MV photon beam was then validated against the measurements for different field sizes (5 x 5, 30 x 30 and 40 x 40 cm(2)) by gamma index analysis. RESULTS: The optimum values for electron energy, spatial FWHM and mean angular spread were 14.2MeV, 0.08cm and 0.8 degree, respectively. The MC simulations yielded the comparable measurement results of these optimum parameters. The gamma passing rates (with acceptance criteria of 1%/1 mm) for percentage depth doses were found to be 100% for all field sizes. For cross-line profiles, the gamma passing rates were 100%, 97%, 95%, 96% and 95% for 5 x 5, 10 x 10, 20 x 20, 30 x 30 and 40 x 40 cm(2) field sizes, respectively. CONCLUSIONS: By validation of the MC model of Siemens Oncor (R) linac using various field sizes, it was found that both dose profiles of small and large field sizes were very sensitive to the changes in spatial FWHM and mean angular spread of the primary electron beam from the bending magnet. Hence, it is recommended that both small and large field sizes of the 18MV photon beams should be considered in the Monte Carlo linac modeling.
引用
收藏
页码:1047 / 1070
页数:24
相关论文
共 50 条
  • [41] Validation of PRIMO Monte Carlo Model of Clinac®iX 6MV Photon Beam
    Sarin, B.
    Bindhu, B.
    Saju, B.
    Nair, Raguram K.
    JOURNAL OF MEDICAL PHYSICS, 2020, 45 (01) : 24 - 35
  • [42] Verification of a Monte Carlo-Based Source Model for a Varian 10 MV Photon Beam
    Davidson, S.
    Cui, J.
    Deasy, J.
    Ibbott, G.
    Followill, D.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [43] A multiple source model for 6 MV photon beam dose calculations using Monte Carlo
    Fix, MK
    Stampanoni, M
    Manser, P
    Born, EJ
    Mini, R
    Rüegsegger, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05): : 1407 - 1427
  • [44] Monte carlo model and output factors of elekta Infinity™ 6 and 10 MV photon beam
    Yani, Sitti
    Budiansah, Indra
    Rhani, Mohamad Fahdillah
    Haryanto, Freddy
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (04) : 470 - 478
  • [45] Initial beam energy determination for Monte Carlo simulation
    Yang, J
    Qin, L
    Li, J
    Ma, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1731 - 1732
  • [46] Validation of Monte Carlo simulation of 6 MV photon beam delivered by Vero4DRT linear accelerator using BEAMnrc and DOSXYZnrc
    Rostamzadeh, Maryam
    Popescu, I. Antoniu
    Mestrovic, Ante
    Gete, Ermias
    Bergman, Alanah M.
    Ishihara, Yoshitomo
    Nakamura, Mitsuhiro
    MEDICAL PHYSICS, 2019, 46 (11) : 5388 - 5388
  • [47] PROPERTIES OF THE 18-MV PHOTON-BEAM FROM A DUAL ENERGY LINEAR-ACCELERATOR
    JOHNSON, DA
    IKORO, NC
    CHANG, CH
    SCARBROUGH, EC
    ANTICH, PP
    MEDICAL PHYSICS, 1987, 14 (06) : 1071 - 1078
  • [48] CHARACTERISTICS OF AN 18 MV PHOTON-BEAM FROM A THERAC 20 MEDICAL LINEAR-ACCELERATOR
    PATTERSON, MS
    SHRAGGE, PC
    MEDICAL PHYSICS, 1981, 8 (03) : 312 - 318
  • [49] Validation of Monte Carlo Model for Dose Evaluation outside the Treatment Field for Siemens 6MV Beam
    Sinousy D.M.
    Attalla E.M.
    Fathy I.H.
    Elhussiny F.A.
    Elmekawy A.F.
    Sinousy, Dina Mohamed, 1600, Mashhad University of Medical Sciences (17): : 410 - 420
  • [50] DETERMINATION OF PRIMARY ELECTRON BEAM PARAMETERS IN MONTE CARLO SIMULATION OF MEDICAL LINAC
    Vaezzadeh, S. A.
    Allahverdi, M.
    Nedaie, H. A.
    Yarahmadi, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S518 - S518