Benchmarking of Monte Carlo model of Siemens Oncor® linear accelerator for 18 MV photon beam: Determination of initial electron beam parameters

被引:4
|
作者
Najafzadeh, Milad [1 ]
Hoseini-Ghafarokhi, Mojtaba [2 ]
Bolagh, Rezgar Shahi Mayn [3 ]
Haghparast, Mohammad [1 ]
Zarifi, Shiva [4 ]
Nickfarjam, Abolfazl [5 ]
Farhood, Bagher [6 ]
Chow, James C. L. [7 ,8 ]
机构
[1] Hormozgan Univ Med Sci, Fac Med, Dept Radiol, Bandare Abbas, Iran
[2] Kermanshah Univ Med Sci, Sch Med Sci, Dept Radiol & Nucl Med, Kermanshah, Iran
[3] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
[4] Semnan Univ Med Sci, Fac Med, Dept Med Phys, Semnan, Iran
[5] Shahid Sadoughi Univ Med Sci, Fac Med, Dept Med Phys, Yazd, Iran
[6] Kashan Univ Med Sci, Fac Paramed Sci, Dept Med Phys & Radiol, Kashan, Iran
[7] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[8] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON, Canada
关键词
Radiotherapy; Monte Carlo simulation; benchmarking; Siemens Oncor; gamma analysis; DOSE DISTRIBUTIONS; RADIOTHERAPY; SENSITIVITY; SIMULATION; INCIDENT; ENERGY; DISCREPANCIES; FLUENCE; SPECTRA; IMPROVE;
D O I
10.3233/XST-190568
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
OBJECTIVE: This study aims to benchmark a Monte Carlo (MC) model of the 18MV photon beam produced by the Siemens Oncor (R) linac using the BEAMnrc and DOSXYZnrc codes. METHODS: By matching the percentage depth doses and beam profiles calculated by MC simulations with measurements, the initial electron beam parameters including electron energy, full width at half maximum (spatial FWHM), and mean angular spread were derived for the 10 x 10 cm(2) and 20 x 20 cm(2) field sizes. The MC model of the 18MV photon beam was then validated against the measurements for different field sizes (5 x 5, 30 x 30 and 40 x 40 cm(2)) by gamma index analysis. RESULTS: The optimum values for electron energy, spatial FWHM and mean angular spread were 14.2MeV, 0.08cm and 0.8 degree, respectively. The MC simulations yielded the comparable measurement results of these optimum parameters. The gamma passing rates (with acceptance criteria of 1%/1 mm) for percentage depth doses were found to be 100% for all field sizes. For cross-line profiles, the gamma passing rates were 100%, 97%, 95%, 96% and 95% for 5 x 5, 10 x 10, 20 x 20, 30 x 30 and 40 x 40 cm(2) field sizes, respectively. CONCLUSIONS: By validation of the MC model of Siemens Oncor (R) linac using various field sizes, it was found that both dose profiles of small and large field sizes were very sensitive to the changes in spatial FWHM and mean angular spread of the primary electron beam from the bending magnet. Hence, it is recommended that both small and large field sizes of the 18MV photon beams should be considered in the Monte Carlo linac modeling.
引用
收藏
页码:1047 / 1070
页数:24
相关论文
共 50 条
  • [31] INVESTIGATION OF PHOTONEUTRON CONTAMINATION FROM THE 18-MV PHOTON BEAM IN A MEDICAL LINEAR ACCELERATOR
    Karaman, Onur
    Tanir, Ayse Gunes
    Karaman, Ceren
    MATERIALI IN TEHNOLOGIJE, 2019, 53 (05): : 699 - 704
  • [32] Development and commissioning of a Monte Carlo photon beam model for Varian Clinac 2100EX linear accelerator
    Mesbahi, A
    Reilly, AJ
    Thwaites, DI
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (06) : 656 - 662
  • [33] Monte Carlo model of the Elekta SLiplus accelerator:: validation of a new MLC component module in BEAM for a 6 MV beam
    Van de Walle, J
    Martens, C
    Reynaert, N
    Palmans, H
    Coghe, M
    De Neve, W
    De Wagter, C
    Thierens, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (03): : 371 - 385
  • [34] Automatic determination of primary electron beam parameters in Monte Carlo simulation
    Pena, Javier
    Gonzalez-Castano, Diego M.
    Gomez, Faustino
    Sanchez-Doblado, Francisco
    Hartmann, Guenther H.
    MEDICAL PHYSICS, 2007, 34 (03) : 1076 - 1084
  • [35] Analysis of characteristics and validation of 6 MV photon beam produced by Elekta Synergy linear accelerator using EGSnrc Monte Carlo code
    Gundem, Esin
    Dirican, Bahar
    RADIATION PHYSICS AND CHEMISTRY, 2021, 184
  • [36] Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams
    Tzedakis, A
    Damilakis, JE
    Mazonakis, M
    Stratakis, J
    Varveris, H
    Gourtsoyiannis, N
    MEDICAL PHYSICS, 2004, 31 (04) : 907 - 913
  • [37] Monte Carlo modelling of clinical accelerator beams and estimation of primary electron beam parameters
    Horova, S.
    Judas, L.
    RADIOPROTECTION, 2018, 53 (01) : 61 - 66
  • [38] A systematic study on the determination of initial beam parameters in Monte Carlo linac simulation
    Aljarrah, K
    Sharp, GC
    Neicu, T
    Jiang, SB
    MEDICAL PHYSICS, 2004, 31 (06) : 1769 - 1769
  • [39] Sensitivity analysis of a non-cylindrically symmetric Monte Carlo beam model of a siemens primus accelerator
    Schreiber, E.
    Chen, J.
    Sawkey, D.
    Faddegon, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2591 - 2591
  • [40] MONTE CARLO SIMULATION OF 6, 10 AND 18 MV PHOTON BEAM DOSE DISTRIBUTION IN A BRAIN TUMOR
    Gonzales-Ccoscco, Alberto E.
    Guzman-Calcina, Carmen S.
    Vega-Ramirez, Jose L.
    MOMENTO-REVISTA DE FISICA, 2023, (67): : 22 - 38