Focal source size measurement for Monte Carlo simulations of percentage depth doses in very small photon fields

被引:1
|
作者
Sham, E. [1 ]
Devic, S. [1 ]
Seuntjens, J. [1 ]
Podgorsak, E. [1 ]
机构
[1] McGill Univ, Ctr Hlth, Montreal, PQ, Canada
关键词
D O I
10.1118/1.2241919
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:2284 / 2284
页数:1
相关论文
共 50 条
  • [1] Measurement of Percentage Depth-Dose Profiles in Very Small Fields
    Khoei, Shadi
    West, Mark
    Kairn, Tanya
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 557 - 560
  • [2] Monte Carlo modeling of small photon fields: Quantifying the impact of focal spot size on source occlusion and output factors, and exploring miniphantom design for small-field measurements
    Scott, Alison J. D.
    Nahum, Alan E.
    Fenwick, John D.
    MEDICAL PHYSICS, 2009, 36 (07) : 3132 - 3144
  • [3] On the relationships between electron spot size, focal spot size, and virtual source position in Monte Carlo simulations
    Sterpin, E.
    Chen, Y.
    Lu, W.
    Mackie, T. R.
    Olivera, G. H.
    Vynckier, S.
    MEDICAL PHYSICS, 2011, 38 (03) : 1579 - 1586
  • [4] MONTE CARLO SIMULATIONS OF THE PHOTON CALIBRATION FIELDS AT THE UNDERGROUND LABORATORY OF PTB
    Kowatari, M.
    Dombrowski, H.
    Neumaier, S.
    RADIATION PROTECTION DOSIMETRY, 2010, 142 (2-4) : 125 - 135
  • [5] Dose calculation accuracy for photon small fields in treatment planning systems with comparison by Monte Carlo simulations
    Abazarfard, Mojtaba
    Azadeh, Payam
    Mostaar, Ahmad
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2021, 27 (03): : 181 - 190
  • [6] Monte Carlo Simulations for Small Electron Field Size Irradiation
    Del Lama, Lucas S.
    Martinez, Alexandre S.
    de Almeida, Adelaide
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 490 - 494
  • [7] Commissioning of virtual linacs for Monte Carlo simulations by optimizing photon source characteristics
    Bush, K
    Popescu, T
    MEDICAL PHYSICS, 2005, 32 (07) : 2411 - 2411
  • [8] Commissioning of virtual linacs for Monte Carlo simulations by optimizing photon source characteristics
    Popescu, I
    Bush, K
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S43 - S44
  • [9] Monte Carlo Simulation On the Percentage Depth Dose Ratio for the Surface Dosimetry Using Tangential Photon Beams
    Chow, J.
    Grigorov, G.
    MEDICAL PHYSICS, 2008, 35 (06) : 2807 - +
  • [10] Monte Carlo simulation of small electron fields collimated by the integrated photon MLC
    Mihaljevic, Josip
    Soukup, Martin
    Dohm, Oliver
    Alber, Markus