A Highly Sensitive and Selective Catalytic Determination of Mercury in Environmental Samples

被引:0
|
作者
Ashraf A. Mohamed
Nagat A. Ahmed
Mohamed F. El-Shahat
机构
[1] Ain Shams University,Department of Chemistry, Faculty of Science
关键词
Catalyzed ligand exchange; Thiourea activator; Mercury determination; Vaccines; Bass fish fillet; Wastewaters;
D O I
暂无
中图分类号
学科分类号
摘要
A simple, selective and highly sensitive spectrophotometric method has been developed for mercury determination utilizing its catalytic effect on the isoniazid-hexacyanoferrate (II) reaction. The paper presents for the first time (1) the catalytic effect of Hg (I) on the cited ligand substitution reactions and (2) the activating effect of thiourea on the behavior of mercury. The reaction was monitored spectrophotometrically at 423 nm using the initial rate method. The optimized reaction conditions were 5.0 mmol L−1 hexacyanoferrate (II), 0.5 mmol L−1 isoniazid, 150 mmol L−1 citrate buffer (pH 3.30 ± 0.05), and 0.2 mmol L−1 thiourea, at 50°C. Linear calibration graphs were obtained for 1–100 and 1–55 µg L−1 with detection limits, based on the 3Sb-criterion, of 1.2 and 1.8 µg L−1 of Hg (II) and Hg (I), respectively. The method was conveniently applied to samples of wastewaters, inactivated vaccines, and frozen Bass fish fillet, without any prior separation or preconcentration.