Economically viable sensitive and selective luminescent sensor for the determination of Au(III) in environmental samples

被引:6
|
作者
Vasimalai, N. [1 ]
Rajalakshmi, K. [1 ]
John, S. Abraham [1 ]
机构
[1] Gandhigram Rural Inst, Ctr Nanosci & Nanotechnol, Dept Chem, Dindigul 624302, Tamil Nadu, India
关键词
CHELATION-ENHANCED FLUORESCENCE; SPECTROFLUOROMETRIC DETERMINATION; STRUCTURAL-CHARACTERIZATION; GOLD NANOPARTICLES; THIOLATE COMPLEXES; IN-VITRO; GOLD(III); 2,5-DIMERCAPTO-1,3,4-THIADIAZOLE; ABSORPTION; ION;
D O I
10.1039/c4ra05217j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper describes the ultrasensitive and selective determination of Au(III) in an aqueous solution using a functionalized mercapto thiadiazole ligand. UV-visible and spectrofluorimetry studies of functionalized mercapto thiadiazole ligands such as 2,5-dimercapto-1,3,4-thiadiazole (DMT), 2-amino-5-mercapto-1,3,4-thiadiazole (AMT) and 2-mercapto-5-methyl-1,3,4-thiadiazole (MMT) were carried out in the presence of Au(III) ions in solution. DMT, AMT and MMT exhibit an absorption maximum at 330, 310 and 299 nm, respectively. The emission intensities of the respective compounds were enhanced at 435, 428 and 442 nm after the addition of 1 nM Au(III); furthermore, the color of the solutions also changed to yellow. The observed color changes and emission intensity enhancement are ascribed to the effective complex formation of Au(III) with DMT, AMT and MMT ligands. When 8 nM Au(III) was added into the aqueous solutions of DMT, AMT and MMT, the emission intensity was enhanced to 102, 8 and 5-fold, respectively. The binding constants for DMT, AMT and MMT-Au(III) complexes were found to be 1.52, 1.05 and 1.04 x 10(5) mol(-1) L, respectively. The higher emission intensity and binding constant value obtained for DMT reveals that the DMT-Au(III) complex is highly fluorescent compared to the other two complexes. Thus, DMT was chosen as a fluorophore for the determination of Au(III). Interestingly, even after the addition of 1 pM Au(III) into DMT solution, the emission intensity was enhanced at 435 nm. Based on the enhancement of emission intensity, we have determined the concentration of Au(III) and the detection limit was found to be 1 pg L-1 (S/N = 3). Furthermore, 60 000-fold higher concentrations of common interferences and 500-fold higher concentration of Cu(II), Pb(II), Ag(I), Ag(II) and Ag(III) did not interfere for the determination of 8 nM Au(III). The proposed method was successfully applied to determine Au(III) in different water samples and the obtained results were validated with ICP-AES. The present method of determination has several advantages, including low cost and environmental friendly nature.
引用
收藏
页码:38812 / 38819
页数:8
相关论文
共 50 条
  • [1] A highly sensitive and selective molecularly imprinted sensor for direct determination of ultra-trace Cr(III) in environmental samples
    Ling, Jun
    Wei, Ge
    Li, Jianping
    CHEMISTRYSELECT, 2022, 7 (10):
  • [2] A Highly Sensitive and Selective Catalytic Determination of Mercury in Environmental Samples
    Ashraf A. Mohamed
    Nagat A. Ahmed
    Mohamed F. El-Shahat
    Bulletin of Environmental Contamination and Toxicology, 2016, 97 : 232 - 236
  • [3] A Highly Sensitive and Selective Catalytic Determination of Mercury in Environmental Samples
    Mohamed, Ashraf A.
    Ahmed, Nagat A.
    El-Shahat, Mohamed F.
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2016, 97 (02) : 232 - 236
  • [4] Determination of Neodymium(III) in Aqueous and Soil Samples with Use of a High-Sensitive and Selective Membrane Sensor
    Pourjavid, Mohammad Reza
    Yousefi, Seyed Reza
    Hosseini, Majid Haji
    Rezaee, Mohammad
    Razavi, Taherehsadat
    Sehat, Ali Akbari
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (06): : 5147 - 5162
  • [5] Highly selective and sensitive spectrofluorimetric method for determination of cypermethrin in different environmental samples
    Muhammad, Mian
    Khan, Sikandar
    Rahim, Gul
    Alharbi, Walaa
    Alharbi, Khadijah H.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2022, 194 (12)
  • [6] Highly selective and sensitive spectrofluorimetric method for determination of cypermethrin in different environmental samples
    Mian Muhammad
    Sikandar Khan
    Gul Rahim
    Walaa Alharbi
    Khadijah H. Alharbi
    Environmental Monitoring and Assessment, 2022, 194
  • [7] Selective Separation, Preconcentration, and Determination of Au (III) Ions in Environmental Samples by Coprecipitation With a 1,2,4-Triazole Derivative
    Ozdes, Duygu
    Duran, Celal
    Serencam, Huseyin
    Sahin, Deniz
    ATOMIC SPECTROSCOPY, 2013, 34 (05) : 164 - +
  • [8] Determination of organophosphorus pesticides in water samples by using a new sensitive luminescent probe of Eu (III) complex
    Azab, Hassan A.
    Anwar, Z. M.
    Rizk, M. A.
    Khairy, Gasser M.
    El-Asfoury, M. H.
    JOURNAL OF LUMINESCENCE, 2015, 157 : 371 - 382
  • [9] Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples
    Gupta, V. K.
    Singh, A. K.
    Gupta, Barkha
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (08) : 2171 - 2181
  • [10] Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples
    V. K. Gupta
    A. K. Singh
    Barkha Gupta
    Analytical and Bioanalytical Chemistry, 2008, 390 : 2171 - 2181