Amperometric hydrogen peroxide sensor based on a sol-gel-derived ceramic carbon composite electrode with toluidine blue covalently immobilized using 3-aminopropyltrimethoxysilane

被引:0
|
作者
K. Thenmozhi
S. Sriman Narayanan
机构
[1] University of Madras,Department of Analytical Chemistry
[2] Guindy Campus,undefined
来源
关键词
Sol-gel; Covalent immobilization; Toluidine blue; Amperometry; Hydrogen peroxide;
D O I
暂无
中图分类号
学科分类号
摘要
A carbon composite amperometric hydrogen peroxide sensor has been developed using a sol-gel technique. Toluidine blue (TB), which acts as the redox mediator, was covalently immobilized via glutaraldehyde crosslinking with an organically modified silane, namely 3-aminopropyltrimethoxysilane (APTMOS). Methyltrimethoxysilane (MTMOS) was used as the additional monomer; this controls the hydrophobicity of the electrode surface, thus limiting the wettability. The immobilization of TB within the sol-gel matrix was confirmed with FTIR studies. The sol-gel mixture containing TB immobilized in APTMOS and MTMOS was mixed with graphite powder in order to prepare the carbon composite electrode. The electrode was characterized using voltammetric techniques and its electrocatalytic activity for the reduction of hydrogen peroxide was also studied. The carbon composite electrode has the advantage of sensing H2O2 at a lower potential and with a higher sensitivity, and interferences due to ascorbic acid, uric acid and acetaminophen were greatly minimized. The linear range for the determination of H2O2 extends from 5.37 × 10−6 to 6.15 × 10−3 M, with a correlation coefficient of 0.9981. The detection limit was found to be 2.15 × 10−6 M. The covalent immobilization of TB effectively prevents the leakage of the water-soluble mediator during measurements. The modified electrode, aside from electrocatalyzing the reduction of H2O2, exhibits distinct advantages in terms of surface renewal in the event of surface fouling, as well as simple preparation, good chemical and mechanical stability, and good reproducibility.
引用
收藏
页码:1075 / 1082
页数:7
相关论文
共 50 条
  • [41] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [42] Amperometric Hydrogen Peroxide Biosensor Based on Horseradish Peroxidase Immobilized on Fe3O4/Chitosan Modified Glassy Carbon Electrode
    Tan, Xuecai
    Zhang, Jinlei
    Tan, Shengwei
    Zhao, Dandan
    Huang, Zenwei
    Mi, Yan
    Huang, Zaiyin
    ELECTROANALYSIS, 2009, 21 (13) : 1514 - 1520
  • [43] Novel Amperometric Hydrogen Peroxide Biosensor Based on Horseradish Peroxidase Azide Covalently Immobilized on Ethynyl-Modified Screen-Printed Carbon Electrode via Click Chemistry
    Hayat, Akhtar
    Marty, Jean-Louis
    Radi, Abd-Elgawad
    ELECTROANALYSIS, 2012, 24 (06) : 1446 - 1452
  • [44] Glucose biosensor based on glucose oxidase immobilized in sol–gel chitosan/silica hybrid composite film on Prussian blue modified glass carbon electrode
    Xue-Cai Tan
    Yuan-Xin Tian
    Pei-Xiang Cai
    Xiao-Yong Zou
    Analytical and Bioanalytical Chemistry, 2005, 381 : 500 - 507
  • [45] Voltammetric and amperometric determination of hydrogen peroxide using a carbon-ceramic electrode modified with a nanohybrid composite made from single-walled carbon nanotubes and silver nanoparticles
    Biuck Habibi
    Mojtaba Jahanbakhshi
    Mohammad Hossein Pournaghi-Azar
    Microchimica Acta, 2012, 177 : 185 - 193
  • [46] Voltammetric and amperometric determination of hydrogen peroxide using a carbon-ceramic electrode modified with a nanohybrid composite made from single-walled carbon nanotubes and silver nanoparticles
    Habibi, Biuck
    Jahanbakhshi, Mojtaba
    Pournaghi-Azar, Mohammad Hossein
    MICROCHIMICA ACTA, 2012, 177 (1-2) : 185 - 193
  • [47] Novel sensitive amperometric hydrogen peroxide sensor using layered hierarchical porous α-MoO3 and GO modified glass carbon electrode
    Li, Bo
    Song, Hai-Yan
    Deng, Zhao-Peng
    Huo, Li-Hua
    Gao, Shan
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 288 : 641 - 648
  • [48] A high-performance wearable microneedle sensor based on a prussian blue-carbon nanotube composite electrode for the detection of hydrogen peroxide and glucose
    Zhu, Jiachen
    Wang, Luwen
    Xu, Shuxiang
    Peng, Liang
    Gao, Zhiyong
    Liu, Shuting
    Xi, Shangbin
    Ma, Shaopeng
    Cai, Wei
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 419
  • [49] Glucose biosensor based on glucose oxidase immobilized in sol-gel chitosan/silica hybrid composite film on Prussian blue modified glass carbon electrode
    Tan, XC
    Tian, YX
    Cai, PX
    Zou, XY
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (02) : 500 - 507
  • [50] A third-generation hydrogen peroxide biosensor based on horseradish peroxidase immobilized by sol gel thin film on a multi-wall carbon nanotube modified electrode
    Xu, Shu-Xia
    Li, Jia-Ling
    Zhou, Zhi-Ling
    Zhang, Cheng-Xiao
    ANALYTICAL METHODS, 2014, 6 (16) : 6310 - 6315