Novel sensitive amperometric hydrogen peroxide sensor using layered hierarchical porous α-MoO3 and GO modified glass carbon electrode

被引:50
|
作者
Li, Bo [1 ,2 ]
Song, Hai-Yan [1 ]
Deng, Zhao-Peng [1 ]
Huo, Li-Hua [1 ]
Gao, Shan [1 ]
机构
[1] Heilongjiang Univ, Sch Chem & Mat Sci, Key Lab Funct Inorgan Mat Chem, Minist Educ, Harbin 150080, Heilongjiang, Peoples R China
[2] Heihe Univ, Coll Sci, Heihe 164300, Peoples R China
基金
中国国家自然科学基金;
关键词
alpha-MoO3; Hierarchical porous structure; Graphene oxide; Electrochemical sensor; Hydrogen peroxide; FREE ELECTROCHEMICAL IMMUNOSENSOR; REDUCED GRAPHENE OXIDE; MOLYBDENUM TRIOXIDE; MESOPOROUS CARBON; RAPID SYNTHESIS; H2O2; NANOPARTICLES; NANOCOMPOSITE; DEPOSITION; NANOFIBERS;
D O I
10.1016/j.snb.2019.03.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The nonenzymatic electrochemical H2O2 sensor based on molybdenum oxides has been rarely reported. In this work, a nonenzymatic electrode, hierarchical porous alpha-MoO3 and graphene oxide decorated glass carbon electrode (alpha-MoO3/GO/GCE) used for H2O2 electrochemical detection, is firstly fabricated by simple layer-by-layer assemble method, in which the alpha-MoO3 is derived by one-step pyrolysis of the regular organic-inorganic hybrid [(H2L)(2)(Mo8O26)](n) [HL = N-(pyridin-3-ylmethyl)pyridine-3-amine] single crystal precursor. The wedge-shaped morphology of the material is accumulated by micro-slices which comprise of nanosheets and small particles with average size of 25 nm. Meanwhile, different types of meso-and macro-pores with the size distributions of 4-6, 20-35 and 100-150 nm are observed, respectively. The alpha-MoO3/GO/GCE sensor based on the optimal ratio of 1:1 shows excellent electrocatalytic H2O2 property at room temperature. It displays the broad linear detection from 0.92 mu M to 2.46 mM and the high sensitivity is calculated to be 391.39 mu A mM(-1) cm(-2) with a low detection limit of 0.31 mu M (S/N = 3). The sensor can achieve 95% steady state current within 5 s and present well stability, reproducibility and anti-interference during H2O2 detection. Furthermore, the sensor is applied for the determination of H2O2 in human serum samples. The excellent performances of this sensor are related to the hierarchical porous structure of alpha-MoO3 and its synergistic effect with GO.
引用
收藏
页码:641 / 648
页数:8
相关论文
共 50 条
  • [1] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jin, Jiayi
    Wu, Wenqin
    Min, Hui
    Wu, Huimin
    Wang, Shengfu
    Ding, Yu
    Yang, Shuijin
    MICROCHIMICA ACTA, 2017, 184 (05) : 1389 - 1396
  • [2] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jiayi Jin
    Wenqin Wu
    Hui Min
    Huimin Wu
    Shengfu Wang
    Yu Ding
    Shuijin Yang
    Microchimica Acta, 2017, 184 : 1389 - 1396
  • [3] An Efficient Amperometric Sensor for Hydrogen Peroxide by Using a Carbon Paste Electrode Modified with Cobalt Impregnated Zeolite
    Norouzi, Banafsheh
    Moradian, Majid
    Malekan, Ali
    PORTUGALIAE ELECTROCHIMICA ACTA, 2015, 33 (02) : 111 - 124
  • [4] A sensitive amperometric hydrogen peroxide sensor based on thionin/EDTA/carbon nanotubes—chitosan composite film modified electrode
    Keying Zhang
    Li Zhang
    Jigui Xu
    Cong Wang
    Tao Geng
    Hongyan Wang
    Jun Zhu
    Microchimica Acta, 2010, 171 : 139 - 144
  • [5] Electrocatalytic Activity of Silver Nanoparticles Modified Glassy Carbon Electrode as Amperometric Sensor for Hydrogen Peroxide
    Maji, Swarup Kumar
    Dutta, Amit Kumar
    Srivastava, Divesh N.
    Paul, Parimal
    Mondal, Anup
    Adhikary, Bibhutosh
    Adhikary, Utsarga
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (07) : 4969 - 4974
  • [6] PEROXIDASE FERROCENE MODIFIED CARBON PASTE ELECTRODE AS AN AMPEROMETRIC SENSOR FOR THE HYDROGEN-PEROXIDE ASSAY
    SANCHEZ, PD
    ORDIERES, AJM
    GARCIA, AC
    BLANCO, PT
    ELECTROANALYSIS, 1991, 3 (4-5) : 281 - 285
  • [7] An Amperometric Sensitive Hydrogen Peroxide Sensor Based on a Silver Nanoparticle-Doped Polyimide-Modified Glassy Carbon Electrode
    Chen, Lin
    Wang, Yue
    Ban, Hao
    Yu, Simin
    Tao, Dongping
    Hu, Zhizhi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (11): : 10961 - 10972
  • [8] A sensitive amperometric hydrogen peroxide sensor based on thionin/EDTA/carbon nanotubes-chitosan composite film modified electrode
    Zhang, Keying
    Zhang, Li
    Xu, Jigui
    Wang, Cong
    Geng, Tao
    Wang, Hongyan
    Zhu, Jun
    MICROCHIMICA ACTA, 2010, 171 (1-2) : 139 - 144
  • [9] Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with copper nanoparticles
    Sophia, J.
    Muralidharan, G.
    MATERIALS RESEARCH BULLETIN, 2015, 70 : 315 - 320
  • [10] An Amperometric Hydrogen Peroxide Sensor Based on Hollow Carbon Spheres/Pt NPs Modified Glassy Carbon Electrode
    Zhang, Yuanyuan
    Duan, Hongliang
    Yuan, Wang
    Li, Yunlong
    Zhang, Yueqi
    Yang, Xiaoling
    Liao, Xiaoling
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (12):