Novel sensitive amperometric hydrogen peroxide sensor using layered hierarchical porous α-MoO3 and GO modified glass carbon electrode

被引:50
|
作者
Li, Bo [1 ,2 ]
Song, Hai-Yan [1 ]
Deng, Zhao-Peng [1 ]
Huo, Li-Hua [1 ]
Gao, Shan [1 ]
机构
[1] Heilongjiang Univ, Sch Chem & Mat Sci, Key Lab Funct Inorgan Mat Chem, Minist Educ, Harbin 150080, Heilongjiang, Peoples R China
[2] Heihe Univ, Coll Sci, Heihe 164300, Peoples R China
基金
中国国家自然科学基金;
关键词
alpha-MoO3; Hierarchical porous structure; Graphene oxide; Electrochemical sensor; Hydrogen peroxide; FREE ELECTROCHEMICAL IMMUNOSENSOR; REDUCED GRAPHENE OXIDE; MOLYBDENUM TRIOXIDE; MESOPOROUS CARBON; RAPID SYNTHESIS; H2O2; NANOPARTICLES; NANOCOMPOSITE; DEPOSITION; NANOFIBERS;
D O I
10.1016/j.snb.2019.03.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The nonenzymatic electrochemical H2O2 sensor based on molybdenum oxides has been rarely reported. In this work, a nonenzymatic electrode, hierarchical porous alpha-MoO3 and graphene oxide decorated glass carbon electrode (alpha-MoO3/GO/GCE) used for H2O2 electrochemical detection, is firstly fabricated by simple layer-by-layer assemble method, in which the alpha-MoO3 is derived by one-step pyrolysis of the regular organic-inorganic hybrid [(H2L)(2)(Mo8O26)](n) [HL = N-(pyridin-3-ylmethyl)pyridine-3-amine] single crystal precursor. The wedge-shaped morphology of the material is accumulated by micro-slices which comprise of nanosheets and small particles with average size of 25 nm. Meanwhile, different types of meso-and macro-pores with the size distributions of 4-6, 20-35 and 100-150 nm are observed, respectively. The alpha-MoO3/GO/GCE sensor based on the optimal ratio of 1:1 shows excellent electrocatalytic H2O2 property at room temperature. It displays the broad linear detection from 0.92 mu M to 2.46 mM and the high sensitivity is calculated to be 391.39 mu A mM(-1) cm(-2) with a low detection limit of 0.31 mu M (S/N = 3). The sensor can achieve 95% steady state current within 5 s and present well stability, reproducibility and anti-interference during H2O2 detection. Furthermore, the sensor is applied for the determination of H2O2 in human serum samples. The excellent performances of this sensor are related to the hierarchical porous structure of alpha-MoO3 and its synergistic effect with GO.
引用
收藏
页码:641 / 648
页数:8
相关论文
共 50 条
  • [21] Amperometric Sensing of Hydrogen Peroxide Using Graphene Oxide-Alizarin Modified Glassy Carbon Electrode
    Muhammet, Sinan Mithat
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):
  • [22] An Amperometric Hydrogen Peroxide Sensor Based on Reduced Graphene Oxide/Carbon Nanotubes/Pt NPs Modified Glassy Carbon Electrode
    Zhang, Yuanyuan
    Cao, Qi
    Zhu, Fengmei
    Xu, Hedan
    Zhang, Yang
    Xu, Wenfeng
    Liao, Xiaoling
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 8771 - 8785
  • [23] A novel nonenzymatic hydrogen peroxide amperometric sensor based on Pd@CeO2-NH2 nanocomposites modified glassy carbon electrode
    Guler, Muhammet
    Turkoglu, Vedat
    Kivrak, Arif
    Karahan, Fatih
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2018, 90 : 454 - 460
  • [24] Highly sensitive hydrogen peroxide sensor based on a glassy carbon electrode modified with platinum nanoparticles on carbon nanofiber heterostructures
    Yang, Yang
    Fu, Renzhong
    Yuan, Jianjun
    Wu, Shiyuan
    Zhang, Jialiang
    Wang, Haiying
    MICROCHIMICA ACTA, 2015, 182 (13-14) : 2241 - 2249
  • [25] Highly sensitive hydrogen peroxide sensor based on a glassy carbon electrode modified with platinum nanoparticles on carbon nanofiber heterostructures
    Yang Yang
    Renzhong Fu
    Jianjun Yuan
    Shiyuan Wu
    Jialiang Zhang
    Haiying Wang
    Microchimica Acta, 2015, 182 : 2241 - 2249
  • [26] Amperometric determination of hydrogen peroxide on surface of a novel PbPCNF-modified carbon-ceramic electrode in acidic medium
    Rami, H.
    Heidari, H.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 625 (02) : 101 - 108
  • [27] A highly sensitive hydrogen peroxide amperometric sensor based on MnO2-modified vertically aligned multiwalled carbon nanotubes
    Xu, Bin
    Ye, Min-Ling
    Yu, Yu-Xiang
    Zhang, Wei-De
    ANALYTICA CHIMICA ACTA, 2010, 674 (01) : 20 - 26
  • [28] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yawen Yuan
    Yiqun Zheng
    Jinglei Liu
    Hua Wang
    Shifeng Hou
    Microchimica Acta, 2017, 184 : 4723 - 4729
  • [29] Amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with a nanocomposite prepared from ferumoxytol and reduced graphene oxide decorated with platinum nanoparticles
    Zhang, Yuanyuan
    Duan, Yulin
    Shao, Zeyu
    Chen, Chen
    Yang, Mei
    Lu, Guodong
    Xu, Wenfeng
    Liao, Xiaoling
    MICROCHIMICA ACTA, 2019, 186 (06)
  • [30] Amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with a nanocomposite prepared from ferumoxytol and reduced graphene oxide decorated with platinum nanoparticles
    Yuanyuan Zhang
    Yulin Duan
    Zeyu Shao
    Chen Chen
    Mei Yang
    Guodong Lu
    Wenfeng Xu
    Xiaoling Liao
    Microchimica Acta, 2019, 186