Novel sensitive amperometric hydrogen peroxide sensor using layered hierarchical porous α-MoO3 and GO modified glass carbon electrode

被引:50
|
作者
Li, Bo [1 ,2 ]
Song, Hai-Yan [1 ]
Deng, Zhao-Peng [1 ]
Huo, Li-Hua [1 ]
Gao, Shan [1 ]
机构
[1] Heilongjiang Univ, Sch Chem & Mat Sci, Key Lab Funct Inorgan Mat Chem, Minist Educ, Harbin 150080, Heilongjiang, Peoples R China
[2] Heihe Univ, Coll Sci, Heihe 164300, Peoples R China
基金
中国国家自然科学基金;
关键词
alpha-MoO3; Hierarchical porous structure; Graphene oxide; Electrochemical sensor; Hydrogen peroxide; FREE ELECTROCHEMICAL IMMUNOSENSOR; REDUCED GRAPHENE OXIDE; MOLYBDENUM TRIOXIDE; MESOPOROUS CARBON; RAPID SYNTHESIS; H2O2; NANOPARTICLES; NANOCOMPOSITE; DEPOSITION; NANOFIBERS;
D O I
10.1016/j.snb.2019.03.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The nonenzymatic electrochemical H2O2 sensor based on molybdenum oxides has been rarely reported. In this work, a nonenzymatic electrode, hierarchical porous alpha-MoO3 and graphene oxide decorated glass carbon electrode (alpha-MoO3/GO/GCE) used for H2O2 electrochemical detection, is firstly fabricated by simple layer-by-layer assemble method, in which the alpha-MoO3 is derived by one-step pyrolysis of the regular organic-inorganic hybrid [(H2L)(2)(Mo8O26)](n) [HL = N-(pyridin-3-ylmethyl)pyridine-3-amine] single crystal precursor. The wedge-shaped morphology of the material is accumulated by micro-slices which comprise of nanosheets and small particles with average size of 25 nm. Meanwhile, different types of meso-and macro-pores with the size distributions of 4-6, 20-35 and 100-150 nm are observed, respectively. The alpha-MoO3/GO/GCE sensor based on the optimal ratio of 1:1 shows excellent electrocatalytic H2O2 property at room temperature. It displays the broad linear detection from 0.92 mu M to 2.46 mM and the high sensitivity is calculated to be 391.39 mu A mM(-1) cm(-2) with a low detection limit of 0.31 mu M (S/N = 3). The sensor can achieve 95% steady state current within 5 s and present well stability, reproducibility and anti-interference during H2O2 detection. Furthermore, the sensor is applied for the determination of H2O2 in human serum samples. The excellent performances of this sensor are related to the hierarchical porous structure of alpha-MoO3 and its synergistic effect with GO.
引用
收藏
页码:641 / 648
页数:8
相关论文
共 50 条
  • [31] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yuan, Yawen
    Zheng, Yiqun
    Liu, Jinglei
    Wang, Hua
    Hou, Shifeng
    MICROCHIMICA ACTA, 2017, 184 (12) : 4723 - 4729
  • [32] A Novel Hydrogen Peroxide Sensor Based on Multiwalled Carbon Nanotubes/Poly(pyrocatechol violet)-Modified Glassy Carbon Electrode
    Fang, Bin
    Zhang, Na
    Zhang, Wei
    Gu, Aixia
    Wang, Guangfeng
    JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 112 (06) : 3488 - 3493
  • [33] Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis
    Schachl, K
    Alemu, H
    Kalcher, K
    Jezkova, J
    Svancara, I
    Vytras, K
    ANALYST, 1997, 122 (09) : 985 - 989
  • [34] Ni-Al/layered double hydroxide/Ag nanoparticle composite modified carbon-paste electrode as a renewable electrode and novel electrochemical sensor for hydrogen peroxide
    Habibi, Biuck
    Azhar, Fahimeh Farshi
    Fakkar, Jhila
    Rezvani, Zolfaghar
    ANALYTICAL METHODS, 2017, 9 (12) : 1956 - 1964
  • [35] A Novel Hydrogen Peroxide Amperometric Sensor based on Thionin Incorporated onto a Mo6S9-xIx Nanowire Modified Glassy Carbon Electrode
    Lin, Hong
    Cheng, Huiming
    Miao, Xiaopei
    Papakonstantinou, Pagona
    Mihailovic, Dragan
    Li, Meixian
    ELECTROANALYSIS, 2009, 21 (23) : 2602 - 2606
  • [36] Fabrication of CaTiO3 modified glassy carbon electrode-based hydrogen peroxide sensor
    Ahmad, Khursheed
    Niyitanga, Theophile
    Pathak, Aarti
    Khan, Rais Ahmad
    Khan, Mohd Quasim
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2024, 21 (08) : 2147 - 2157
  • [37] An amperometric sensor based on Prussian blue and poly(o-phenylenediamine) modified glassy carbon electrode for the determination of hydrogen peroxide in beverages
    Ping, Jianfeng
    Wu, Jian
    Fan, Kai
    Ying, Yibin
    FOOD CHEMISTRY, 2011, 126 (04) : 2005 - 2009
  • [38] AMPEROMETRIC ENZYME SENSOR FOR GLUCOSE WITH THE USE OF GLUCOSE-OXIDASE AND CARBON PASTE ELECTRODE MODIFIED WITH CATALYST FOR HYDROGEN-PEROXIDE OXIDATION
    MIZUTANI, F
    YABUKI, S
    KATSURA, T
    DENKI KAGAKU, 1992, 60 (12): : 1141 - 1142
  • [39] NOVEL HYDROGEN PEROXIDE SENSOR USING A MULTIWALLED CARBON NANOTUBE-COBALAMIN NANOCOMPOSITE GLASSY CARBON ELECTRODE
    Liu, Suqin
    Dai, Gaopeng
    Luo, Tianxiong
    Wang, Jingwen
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2015, 43 (06) : 649 - 660
  • [40] A novel and sensitive amperometric hydrazine sensor based on gold nanoparticles decorated graphite nanosheets modified screen printed carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Ramaraj, Sayee Kannan
    Periakaruppan, Prakash
    ELECTROCHIMICA ACTA, 2014, 139 : 157 - 164