Amperometric hydrogen peroxide sensor based on a sol-gel-derived ceramic carbon composite electrode with toluidine blue covalently immobilized using 3-aminopropyltrimethoxysilane

被引:0
|
作者
K. Thenmozhi
S. Sriman Narayanan
机构
[1] University of Madras,Department of Analytical Chemistry
[2] Guindy Campus,undefined
来源
关键词
Sol-gel; Covalent immobilization; Toluidine blue; Amperometry; Hydrogen peroxide;
D O I
暂无
中图分类号
学科分类号
摘要
A carbon composite amperometric hydrogen peroxide sensor has been developed using a sol-gel technique. Toluidine blue (TB), which acts as the redox mediator, was covalently immobilized via glutaraldehyde crosslinking with an organically modified silane, namely 3-aminopropyltrimethoxysilane (APTMOS). Methyltrimethoxysilane (MTMOS) was used as the additional monomer; this controls the hydrophobicity of the electrode surface, thus limiting the wettability. The immobilization of TB within the sol-gel matrix was confirmed with FTIR studies. The sol-gel mixture containing TB immobilized in APTMOS and MTMOS was mixed with graphite powder in order to prepare the carbon composite electrode. The electrode was characterized using voltammetric techniques and its electrocatalytic activity for the reduction of hydrogen peroxide was also studied. The carbon composite electrode has the advantage of sensing H2O2 at a lower potential and with a higher sensitivity, and interferences due to ascorbic acid, uric acid and acetaminophen were greatly minimized. The linear range for the determination of H2O2 extends from 5.37 × 10−6 to 6.15 × 10−3 M, with a correlation coefficient of 0.9981. The detection limit was found to be 2.15 × 10−6 M. The covalent immobilization of TB effectively prevents the leakage of the water-soluble mediator during measurements. The modified electrode, aside from electrocatalyzing the reduction of H2O2, exhibits distinct advantages in terms of surface renewal in the event of surface fouling, as well as simple preparation, good chemical and mechanical stability, and good reproducibility.
引用
收藏
页码:1075 / 1082
页数:7
相关论文
共 50 条
  • [21] Electrocatalytic Oxidation of Hydrogen Peroxide at a Sol-gel Derived Carbon Ceramic Electrode Modified with Copper Iodide
    Karim-Nezhad, Ghasem
    Pashazadeh, Sara
    Pashazadeh, Ali
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2013, 60 (12) : 1442 - 1448
  • [22] Renewable-surface amperometric nitrite sensor based on sol-gel-derived silicomolybdate-methylsilicate-graphite composite material
    Wang, P
    Wang, XP
    Bi, LH
    Zhu, GY
    ANALYST, 2000, 125 (07) : 1291 - 1294
  • [23] Sol-gel derived carbon ceramic composite electrode containing a ruthenium complex for amperometric detection of insulin at physiological pH
    Salimi, A
    Pourbeyram, S
    Haddadzadeh, H
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 542 : 39 - 49
  • [24] Hydrogen peroxide biosensor with enzyme entrapped within electrodeposited polypyrrole based on mediated sol-gel derived composite carbon electrode
    Tian, FM
    Xu, B
    Zhu, LD
    Zhu, GY
    ANALYTICA CHIMICA ACTA, 2001, 443 (01) : 9 - 16
  • [25] Amperometric sensor for hydrogen peroxide based on electric wire composed of horseradish peroxidase and toluidine blue-multiwalled carbon nanotubes nanocomposite
    Liu, Ying
    Lei, Jianping
    Ju, Huangxian
    TALANTA, 2008, 74 (04) : 965 - 970
  • [26] Amperometric immunosensor for probing complement III (C3) based on immobilizing C3 antibody to a nano-Au monolayer supported by sol-gel-derived carbon ceramic electrode
    Lei, CX
    Yang, Y
    Wang, H
    Shen, GL
    Yu, RQ
    ANALYTICA CHIMICA ACTA, 2004, 513 (02) : 379 - 384
  • [27] Surface renewable sol-gel composite electrode derived from 3-aminopropyl trimethoxy silane with covalently immobilized thionin
    Thenmozhi, K.
    Narayanan, S. Sriman
    BIOSENSORS & BIOELECTRONICS, 2007, 23 (05): : 606 - 612
  • [28] Amperometric Tyrosinase Biosensor Based on Carbon Nanotube-Doped Sol-Gel-Derived Zinc Oxide-Nafion Composite Films
    Lee, Joong Min
    Xu, Guang-Ri
    Kim, Byung Kun
    Choi, Han Nim
    Lee, Won-Yong
    ELECTROANALYSIS, 2011, 23 (04) : 962 - 970
  • [29] A sensitive amperometric hydrogen peroxide sensor based on thionin/EDTA/carbon nanotubes—chitosan composite film modified electrode
    Keying Zhang
    Li Zhang
    Jigui Xu
    Cong Wang
    Tao Geng
    Hongyan Wang
    Jun Zhu
    Microchimica Acta, 2010, 171 : 139 - 144
  • [30] A hydrogen peroxide biosensor combined HRP doped polypyrrole with ferrocene modified sol-gel derived composite carbon electrode
    Tian, FM
    Xu, B
    Zhu, GY
    CHINESE CHEMICAL LETTERS, 2001, 12 (07) : 625 - 628