Physical and biological pretreatment quality assurance of the head and neck cancer plan with the volumetric modulated arc therapy

被引:0
|
作者
So-Hyun Park
Dong-Soo Lee
Yun-Hee Lee
Seu-Ran Lee
Min-Ju Kim
Tae-Suk Suh
机构
[1] Uijeongbu St. Mary’s hospital,Department of Radiation Oncology
[2] Seoul St. Mary’s hospital,Department of Radiation Oncology
[3] The Catholic University of Korea College of Medicine,Department of Biomedical Engineering
来源
关键词
Quality assurance; Gamma passing rates; False negative; EUD; TCP/NTCP;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this work is to demonstrate both the physical and the biological quality assurance (QA) aspects as pretreatment QA of the head and neck (H&N) cancer plan for the volumetric modulated arc therapy (VMAT). Ten H&N plans were studied. The COMPASS® dosimetry analysis system and the tumor control probability (TCP) and the normal tissue complication probability (NTCP) calculation free program were used as the respective measurement and calculation tools. The reliability of these tools was verified by a benchmark study in accordance with the TG-166 report. For the physical component of QA, the gamma passing rates and the false negative cases between the calculated and the measured data were evaluated. The biological component of QA was performed based on the equivalent uniform dose (EUD), TCP and NTCP values. The evaluation was performed for the planning target volumes (PTVs) and the organs at risks (OARs), including the eyes, the lens, the parotid glands, the esophagus, the spinal cord, and the brainstem. All cases had gamma passing rates above 95% at an acceptance tolerance level with the 3%/3 mm criteria. In addition, the false negative instances were presented for the PTVs and OARs. The gamma passing rates exhibited a weak correlation with false negative cases. For the biological QA, the physical dose errors affect the EUD and the TCP for the PTVs, but no linear correlation existed between them. The EUD and NTCP for the OARs were shown the random differences that could not be attributed to the dose errors from the physical QA. The differences in the EUD and NTCP between the calculated and the measured results were mainly demonstrated for the parotid glands. This study describes the importance and the necessity of improved QA to accompany both the physical and the biological aspects for accurate radiation treatment.
引用
收藏
页码:946 / 955
页数:9
相关论文
共 50 条
  • [41] The NCS code of practice for the quality assurance and control for volumetric modulated arc therapy
    Mans, Anton
    Schuring, Danny
    Arends, Mark P.
    Vugts, Cornelia A. J. M.
    Wolthaus, Jochem W. H.
    Lotz, Heidi T.
    Admiraal, Marjan
    Louwe, Rob J. W.
    Ollers, Michel C.
    van de Kamer, Jeroen B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (19): : 7221 - 7235
  • [42] Identical Quality Assurance for Volumetric Modulated Arc Therapy in Elekta and Varian Machines
    Wang, Jiazhou
    Hu, Weigang
    Peng, Jiayuan
    Lu, Saiquan
    Zhao, Jun
    Xiao, Ying
    Zhang, Zhen
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (04) : 483 - 490
  • [43] TOWARDS AUTOMATIC QUALITY ASSURANCE (QA) OF VOLUMETRIC MODULATED ARC THERAPY (VMAT)
    Ruchaud, R.
    Rodrigues, C.
    Gibon, D.
    Massoptier, L.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S154 - S154
  • [44] Quality Assurance of Multiple Isocentric Volumetric Modulated Arc Therapy for Craniospinal Irradiation
    Zhang, J.
    Lee, B.
    Lien, W.
    Han, J.
    Kim, D.
    Goldman, K.
    Lu, S.
    Hong, G.
    Lee, S.
    Rahimian, J.
    Qian, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E609 - E609
  • [45] Identical Quality Assurance for Volumetric Modulated Arc Therapy in Elekte and Varian Machines
    Wang, J.
    Xiao, Y.
    Hu, W.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [46] Potential advantages of volumetric arc therapy in head and neck cancer
    Gomez-Millan Barrachina, Jaime
    Jerez Sainz, Inmaculada
    Perez Rozos, Alberto
    Ramirez Ros, J. Carlos
    Toledo Serrano, M. Dolores
    Lupianez Perez, Yolanda
    Medina Carmona, J. Antonio
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2015, 37 (06): : 909 - 914
  • [47] Implementation of Volumetric Arc Therapy (VMAT) for Head and Neck Cancer
    Lamb, G.
    Smith, S.
    Glegg, M.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S24 - S24
  • [48] A Comparative Study on the Head and Neck Radiation Therapy for Dynamic Conformal Arc Therapy and Volumetric Modulated Arc Therapy
    Kim, Deok-Ki
    Choi, Cheon Woong
    Choi, Jae-Hyock
    Won, Hui-Su
    Park, Cheol-Soo
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2015, 25 (06): : 208 - 218
  • [49] Quality and mechanical efficiency of automated knowledge-based planning for volumetric-modulated arc therapy in head and neck cancer
    Thongsawad, Sangutid
    Chamchod, Sasikarn
    Chawengsaksopak, Kornkanok
    Masanga, Wilai
    Deeharing, Aphisara
    Bawornpatarapakorn, Sarinya
    Prachanukul, Thitiwan
    Tannanonta, Chirapha
    Udee, Nuntawat
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (02):
  • [50] Treatment Plan Complexity Quantification for Predicting Patient-Specific Quality Assurance of Stereotactic Volumetric Modulated Arc Therapy
    Xudong, X.
    Ding, Y.
    Wei, W.
    Ma, C.
    Wang, X.
    MEDICAL PHYSICS, 2022, 49 (06) : E286 - E287