Daily Based Quality Assurance of Volumetric Modulated Arc Therapy for the Full Session of Treatment

被引:0
|
作者
Mohammad Mahfujur Rahman
Chan Hyeong Kim
Seonghoon Kim
机构
[1] Hanyang University,Department of Nuclear Engineering
[2] Hanyang University Medical Center,Department of Radiation Oncology
来源
关键词
RapidArc; MLC; Quality assurance; Portal dosimetry; Dynalog files;
D O I
暂无
中图分类号
学科分类号
摘要
Volumetric modulated arc therapy (VMAT) with highly complex advanced delivering technique, is widely practiced in radiation therapy and requires a quality assurance for treatment plan at least once a treatment session. In this study we collected six VMAT patients with different treatment sites. The VMAT plans and their quality assurance (QA) plans were performed on a daily basis before treatment for their full period of treatment. We tried to evaluate the accuracy of their delivering through analyses of first mechanical error of multileaf collimator (MLC) movement and second dosimetric error of beam delivery. We used a MATLAB program and portal dosimetry to estimate a maximum root mean square (RMS) error from dynalog files for mechanical analysis and a gamma index from portal dosimetry for dosimetric analysis, respectively. We introduced newly in this study a representative VMAT QA to be used to perform a routine VMAT QA. The daily variation of maximum error RMSs for all treatment sites were all below maximum 0.3503 ± 0.0002 mm for treatment plans and QA plans and they all showed the gamma pass rate of more than 98%. Mean of inter difference between treatment and QA plans stayed below 0.04 mm, showing that QA deliveries agree well with treatment deliveries. The Linac used kept a good performance within the tolerances in American Association of Physicists in Medicine (AAPM) TG142 guideline for the period of research. We suggest that the representative VMAT QA can be a good surrogate for real VMAT plan and “whole time” plan QA for a patient selected randomly at least once a year be performed to confirm the long-term stability of Linac performance.
引用
收藏
页码:990 / 1000
页数:10
相关论文
共 50 条
  • [41] Volumetric Modulated Arc Therapy for the Treatment of Paraspinal Lesions
    Happersett, L.
    Zhang, P.
    Wang, K.
    Jackson, A.
    Yamada, Y.
    Mageras, G.
    Hunt, M.
    MEDICAL PHYSICS, 2009, 36 (06) : 2543 - +
  • [42] Volumetric Modulated Arc Therapy
    Shepard, D.
    Popple, R.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] Evaluation of volumetric modulated arc therapy for postmastectomy treatment
    Geoffrey P Nichols
    Jonas D Fontenot
    John P Gibbons
    Mary Ella Sanders
    Radiation Oncology, 9
  • [44] Volumetric Modulated Arc Therapy
    Shepard, D.
    Popple, R.
    MEDICAL PHYSICS, 2012, 39 (06) : 3858 - 3858
  • [45] Quality assurance-based optimization (QAO): Towards improving patient-specific quality assurance in volumetric modulated arc therapy plans using machine learning
    Wall, Phillip D. H.
    Fontenot, Jonas D.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 87 : 136 - 143
  • [46] Retrospective analysis of portal dosimetry pre-treatment quality assurance of prostate volumetric-modulated arc therapy (VMAT) plans
    Maraghechi, Borna
    Davis, Jack
    Badu, Shyam
    Fleck, Andre
    Darko, Johnson
    Osei, Ernest
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 44 - 52
  • [47] COMMISSIONING AND QUALITY ASSURANCE OF INTENSITY-MODULATED ARC THERAPY
    Bedford, J.
    Warrington, A.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S25 - S25
  • [48] The quality assurance of volumetric modulated arc therapy (VMAT) plans for early stage prostate cancer: a technical note
    Elith, Craig A.
    Dempsey, Shane E.
    Cao, Fred
    Farshadi, Afrooz
    Warren-Forward, Helen M.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2014, 61 (04): : 261 - 266
  • [49] Reduction of systematic dosimetric uncertainties in volumetric modulated arc therapy triggered by patient-specific quality assurance
    Mans, Anton
    Rozendaal, Roel
    Janssen, Tomas
    Damen, Eugene
    Kaas, Jochem
    van Mourik, Anke
    Mijnheer, Ben
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 21 : 6 - 10
  • [50] Feasibility study of multi-purpose quality assurance phantom for pretreatment verification of volumetric modulated arc therapy
    Won, H. S.
    Chung, J. B.
    Eom, K. Y.
    Hwang, D. G.
    Kang, S. W.
    Suh, T. S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (03): : 279 - 287