The quality assurance of volumetric modulated arc therapy (VMAT) plans for early stage prostate cancer: a technical note

被引:3
|
作者
Elith, Craig A. [1 ,2 ]
Dempsey, Shane E. [2 ]
Cao, Fred [1 ]
Farshadi, Afrooz [1 ]
Warren-Forward, Helen M. [2 ]
机构
[1] British Columbia Canc Agcy, Fraser Valley Ctr, Surrey, BC, Canada
[2] Univ Newcastle, Sch Hlth Sci, Callaghan, NSW, Australia
来源
JOURNAL OF MEDICAL RADIATION SCIENCES | 2014年 / 61卷 / 04期
关键词
ArcCHECK; IMSure; quality assurance; VMAT;
D O I
10.1002/jmrs.78
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As radiation therapy transitions from intensity modulated radiation therapy (IMRT) to volumetric modulated arc therapy (VMAT) it is important to consider the quality assurance (QA) of VMAT plans in light of what has previously been learned and developed in IMRT QA. This technical note assesses if IMRT based plan QA software, which has reduced the need in IMRT for phantom dose measurements on the linear accelerator, can be incorporated into VMAT QA processes. Twenty prostate cases were retrospectively planned using VMAT with one arc to deliver a prescription of 74 Gy in 37 fractions. A plan QA was performed using both IMSure (version 3.3), a software-based IMRT QA program, and ArcCHECK (version 6.2.3.5713), a phantom-based VMAT QA tool. Outcomes assessed included the time needed to perform the QA of both the IMSure and ArcCHECK QA methods, and agreement between planned dose and QA measured dose. On average per case, the ArcCHECK technique needed 31.5 min to perform the VMAT plan QA, while IMSure required 3.5 min to perform the same QA. All 20 cases passed dosimetric QA using ArcCHECK. However, using IMSure, three cases failed dosimetric QA using the departments existing IMRT QA criteria. This research has demonstrated that the IMRT QA software IMSure may be incorporated into the QA of VMAT plans, however the criteria to assess the dosimetry of the VMAT plans may need to be different to that for IMRT cases. The implication of this research for radiation therapists is to be critically aware of the differences between the plan QA requirements and methods for IMRT and those required for VMAT.
引用
收藏
页码:261 / 266
页数:6
相关论文
共 50 条
  • [1] Geometric and Dosimetric Quality Assurance in Volumetric Modulated Arc Therapy (VMAT)
    Qian, J.
    Ma, Y.
    Lee, L.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S639 - S639
  • [2] Quality Assurance (QA) of Volumetric Modulated Arc Therapy (VMAT) Treatment Plans: Analysis of 1000 Patients
    Daniel, N.
    Largeron, G.
    Josserand, F.
    Daeira, E.
    Fafi, S.
    Hajji, Z.
    Wheeler, A.
    Khodri, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S794 - S795
  • [3] Retrospective analysis of portal dosimetry pre-treatment quality assurance of prostate volumetric-modulated arc therapy (VMAT) plans
    Maraghechi, Borna
    Davis, Jack
    Badu, Shyam
    Fleck, Andre
    Darko, Johnson
    Osei, Ernest
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 44 - 52
  • [4] TOWARDS AUTOMATIC QUALITY ASSURANCE (QA) OF VOLUMETRIC MODULATED ARC THERAPY (VMAT)
    Ruchaud, R.
    Rodrigues, C.
    Gibon, D.
    Massoptier, L.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S154 - S154
  • [5] VOLUMETRIC MODULATED ARC THERAPY(VMAT) FOR THE TREATMENT OF LOCALIZED PROSTATE CANCER
    Shiraishi, Kenshiro
    Yamamoto, Kentaro
    Haga, Akihiro
    Sakumi, Akira
    Nomoto, Akihiro
    Nakagawa, Keiichi
    ANNALS OF ONCOLOGY, 2014, 25
  • [6] Impact of treatment planning quality assurance software on volumetric-modulated arc therapy plans for prostate cancer patients
    Sasaki, Motoharu
    Nakaguchi, Yuji
    Kamomae, Takeshi
    Kajino, Akimi
    Ikushima, Hitoshi
    MEDICAL DOSIMETRY, 2021, 46 (04) : E1 - E6
  • [7] Quality assurance of volumetric modulated arc therapy for a prostate cancer patient with a hip prosthesis
    Ikeda, T.
    Moriwaki, H.
    Sakumi, A.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S595 - S595
  • [8] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Amoabeng, Kwame Anokye
    Marthinsen, Anne Beate Langeland
    Hasford, Francis
    Tagoe, Samuel Nii Adu
    Anaafi, Evelyn
    HEALTH AND TECHNOLOGY, 2022, 12 (04) : 779 - 786
  • [9] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Kwame Anokye Amoabeng
    Anne Beate Langeland Marthinsen
    Francis Hasford
    Samuel Nii Adu Tagoe
    Evelyn Anaafi
    Health and Technology, 2022, 12 : 779 - 786
  • [10] Pelvic Volumetric Modulated Arc Therapy (VMAT) for Prostate for Locally Advanced Prostate Cancer
    Ferrer, F.
    Ballon, K.
    Boladeras, A.
    De Blas, R.
    Najjari, D.
    Ventura, M.
    Bavestrello, P.
    Rojas, F.
    Bejar, S.
    Zardoya, E.
    Martinez, E.
    Comas, S.
    Gutierrez, C.
    Pera, J.
    Picon, C.
    Guedea, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E249 - E249