Quality assurance of volumetric modulated arc therapy for a prostate cancer patient with a hip prosthesis

被引:0
|
作者
Ikeda, T. [1 ]
Moriwaki, H. [1 ]
Sakumi, A. [2 ]
机构
[1] Mitsui Mem Hosp, Radiol, Tokyo, Japan
[2] Univ Tokyo, Radiol, Tokyo, Japan
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PO-1100
引用
收藏
页码:S595 / S595
页数:1
相关论文
共 50 条
  • [1] Volumetric modulated arc therapy for prostate cancer patients with hip prosthesis
    Prabhakar, Ramachandran
    Kumar, Milind
    Cheruliyil, Suja
    Jayakumar, Silpa
    Balasubramanian, Satheesan
    Cramb, Jim
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2013, 18 (04) : 209 - 213
  • [2] Anatomy-based volumetric modulated arc therapy for a prostate cancer patient with a hip prosthesis
    Kunishima, Naoaki
    Naoi, Yutaka
    Yoda, Kiyoshi
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (02) : 398 - 400
  • [3] Patient specific quality assurance of volumetric modulated arc therapy of synchronous bilateral breast cancer
    Zamo, Francis C. Djoumessi
    Njeh, Christopher F.
    Colliaux, Anthony
    Blot-Lafond, Valerie
    Moyo, M. Ndontchueng
    MEDICAL DOSIMETRY, 2024, 49 (03) : 177 - 184
  • [4] Volumetric modulated arc therapy for prostate cancer
    Afghan, M. K. N.
    Cao, D.
    Mehta, V.
    Wong, T.
    Ye, J.
    Shepard, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S665 - S666
  • [5] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Amoabeng, Kwame Anokye
    Marthinsen, Anne Beate Langeland
    Hasford, Francis
    Tagoe, Samuel Nii Adu
    Anaafi, Evelyn
    HEALTH AND TECHNOLOGY, 2022, 12 (04) : 779 - 786
  • [6] The quality assurance of volumetric modulated arc therapy (VMAT) plans for early stage prostate cancer: a technical note
    Elith, Craig A.
    Dempsey, Shane E.
    Cao, Fred
    Farshadi, Afrooz
    Warren-Forward, Helen M.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2014, 61 (04): : 261 - 266
  • [7] A Systematic Approach to Patient-Specific Quality Assurance for Volumetric Modulated Arc Therapy
    SONG Yu-lin
    Ceferino Obcemea
    Boris Mueller
    Borys Mychalczak
    Chinese Journal of Biomedical Engineering, 2015, 24 (02) : 58 - 65
  • [8] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Kwame Anokye Amoabeng
    Anne Beate Langeland Marthinsen
    Francis Hasford
    Samuel Nii Adu Tagoe
    Evelyn Anaafi
    Health and Technology, 2022, 12 : 779 - 786
  • [9] Multileaf Collimator Quality Assurance for Volumetric Modulated Arc Therapy
    Lin, T.
    Hossain, M.
    Ma, C.
    MEDICAL PHYSICS, 2011, 38 (06) : 3598 - U31
  • [10] Quality assurance of dynamic parameters in volumetric modulated arc therapy
    Manikandan, A.
    Sarkar, B.
    Holla, R.
    Vivek, T. R.
    Sujatha, N.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1015): : 1002 - 1010