Daily Based Quality Assurance of Volumetric Modulated Arc Therapy for the Full Session of Treatment

被引:0
|
作者
Mohammad Mahfujur Rahman
Chan Hyeong Kim
Seonghoon Kim
机构
[1] Hanyang University,Department of Nuclear Engineering
[2] Hanyang University Medical Center,Department of Radiation Oncology
来源
关键词
RapidArc; MLC; Quality assurance; Portal dosimetry; Dynalog files;
D O I
暂无
中图分类号
学科分类号
摘要
Volumetric modulated arc therapy (VMAT) with highly complex advanced delivering technique, is widely practiced in radiation therapy and requires a quality assurance for treatment plan at least once a treatment session. In this study we collected six VMAT patients with different treatment sites. The VMAT plans and their quality assurance (QA) plans were performed on a daily basis before treatment for their full period of treatment. We tried to evaluate the accuracy of their delivering through analyses of first mechanical error of multileaf collimator (MLC) movement and second dosimetric error of beam delivery. We used a MATLAB program and portal dosimetry to estimate a maximum root mean square (RMS) error from dynalog files for mechanical analysis and a gamma index from portal dosimetry for dosimetric analysis, respectively. We introduced newly in this study a representative VMAT QA to be used to perform a routine VMAT QA. The daily variation of maximum error RMSs for all treatment sites were all below maximum 0.3503 ± 0.0002 mm for treatment plans and QA plans and they all showed the gamma pass rate of more than 98%. Mean of inter difference between treatment and QA plans stayed below 0.04 mm, showing that QA deliveries agree well with treatment deliveries. The Linac used kept a good performance within the tolerances in American Association of Physicists in Medicine (AAPM) TG142 guideline for the period of research. We suggest that the representative VMAT QA can be a good surrogate for real VMAT plan and “whole time” plan QA for a patient selected randomly at least once a year be performed to confirm the long-term stability of Linac performance.
引用
收藏
页码:990 / 1000
页数:10
相关论文
共 50 条
  • [21] Quality assurance of volumetric modulated arc therapy: Evaluation and comparison of different dosimetric systems
    Masi, L.
    Casamassima, F.
    Doro, R.
    Francescon, P.
    MEDICAL PHYSICS, 2011, 38 (02) : 612 - 621
  • [22] Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)
    Kwame Anokye Amoabeng
    Anne Beate Langeland Marthinsen
    Francis Hasford
    Samuel Nii Adu Tagoe
    Evelyn Anaafi
    Health and Technology, 2022, 12 : 779 - 786
  • [23] Evaluation of Electronic Portal Imaging Device in the Quality Assurance of Volumetric Modulated Arc Therapy
    Liu, Z.
    Chan, P.
    Li, S.
    Micaily, B.
    Miyamoto, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [24] A FAST FOURIER TRANSFORM BASED DOSE CALCULATION PROGRAM FOR QUALITY ASSURANCE OF VOLUMETRIC INTENSITY-MODULATED ARC THERAPY TREATMENT PLANS
    Cheung, M. L. M.
    Lee, K. Y.
    Chau, M. C.
    Chan, S. K.
    Cheung, K. Y.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S531 - S531
  • [25] COMPARISON OF THREE COMMERCIAL PHANTOMS FOR QUALITY ASSURANCE (QA) OF VOLUMETRIC MODULATED ARC THERAPY (VMAT).
    Pignoli, E.
    Giandini, T.
    Stucchi, C.
    Mongioj, V.
    Zonca, G.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S532 - S532
  • [26] Patient specific quality assurance of volumetric modulated arc therapy of synchronous bilateral breast cancer
    Zamo, Francis C. Djoumessi
    Njeh, Christopher F.
    Colliaux, Anthony
    Blot-Lafond, Valerie
    Moyo, M. Ndontchueng
    MEDICAL DOSIMETRY, 2024, 49 (03) : 177 - 184
  • [27] Quality assurance of volumetric-modulated arc therapy head and neck cancer treatment using PRESAGE (R) dosimeter
    Rehman, Jalil Ur
    Isa, Muhammad
    Ahmad, Nisar
    Asghar, H. M. Noor ul Huda Khan
    Gilani, Zaheer A.
    Chow, James C. L.
    Afzal, Muhammad
    Ibbott, Geoffrey S.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (04) : 441 - 446
  • [28] Analyses of integrated EPID images for on-treatment quality assurance to account for interfractional variations in volumetric modulated arc therapy
    Matsushita, Norimasa
    Nakamura, Mitsuhiro
    Sasaki, Makoto
    Yano, Shinsuke
    Yoshimura, Michio
    Mizowaki, Takashi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 110 - 116
  • [29] Impact of treatment planning quality assurance software on volumetric-modulated arc therapy plans for prostate cancer patients
    Sasaki, Motoharu
    Nakaguchi, Yuji
    Kamomae, Takeshi
    Kajino, Akimi
    Ikushima, Hitoshi
    MEDICAL DOSIMETRY, 2021, 46 (04) : E1 - E6
  • [30] Volumetric Modulated Arc Therapy Treatment Quality Assurance Using An Ion Chamber Array and a Software-Modified Phantom
    Han, B.
    Phillips, T.
    Luxton, G.
    MEDICAL PHYSICS, 2012, 39 (06) : 3785 - 3786