Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups

被引:0
|
作者
Feng Wu
Ting Huang
Yangjian Hu
Xin Yang
Yuejun Ouyang
Qingji Xie
机构
[1] Hunan Normal University,Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education), College of Chemistry and Chemical Engineering
[2] Huaihua College,Chemistry and Material Engineering Department
来源
Microchimica Acta | 2016年 / 183卷
关键词
Chemical sensor; Anodization; Cyclic voltammetry; Differential pulse voltammetry; Ascorbic acid; Dopamine; Uric acid; Urine analysis;
D O I
暂无
中图分类号
学科分类号
摘要
A glassy carbon electrode (GCE) was anodically oxidized by cyclic voltammetry (CV) in 0.05 M sulfuric acid to introduce hydroxy groups on its surface (GCEox). Next, an imidazolium alkoxysilane (ImAS) is covalently tethered to the surface of the GCEox via silane chemistry. This electrode is further modified with graphene oxide (GO) which, dispersed in water, spontaneously assembles on the electrode surface through electrostatic interaction and π-interaction to give an electrode of type GO/ImAS/GCE. Electroreduction of GO and GCEox by CV yields electroreduced GO (erGO) and an electrode of the type erGO/ImAS/GCE. This electrode displays excellent electrocatalytic activity for the oxidation of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Three fully resolved anodic peaks (at −50 mV, 150 mV and 280 mV vs. Ag/AgCl) are observed during differential pulse voltammetry (DPV). Under optimized conditions, the linear detection ranges are from 30 to 2000 μM for AA, from 20 to 490 μM for UA, and from 0.1 to 5 μM and from 5 μM to 200 μM (two linear ranges) for DA. The respective limits of detection (for an S/N of 3) are 10 μM, 5 μM and 0.03 μM. The GCE modified with erGO and ImAS performs better than a bare GCE or a GCE modified with ImAS only, and also outperforms many other reported electrodes for the three analytes. The method was successfully applied to simultaneous analysis of AA, DA and UA in spiked human urine.
引用
收藏
页码:2539 / 2546
页数:7
相关论文
共 50 条
  • [21] Sensitive determination of ascorbic acid, dopamine and uric acid by glassy carbon electrodes modified with β-cyclodextrin and graphene oxide
    Qiwen Guo
    Siyuan Liu
    Xinpeng Men
    Zhe Chen
    Lei Yao
    Geming Wang
    Hongyang Zhao
    Zhidong Lin
    Qian Wu
    Journal of Materials Science: Materials in Electronics, 2022, 33 : 23566 - 23579
  • [22] Simultaneous voltammetric measurement of ascorbic acid, epinephrine and uric acid at a glassy carbon electrode modified with caffeic acid
    Ren, W
    Luo, HQ
    Li, NB
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (07): : 1086 - 1092
  • [23] A glassy carbon electrode modified with a nanocomposite consisting of MoS2 and reduced graphene oxide for electrochemical simultaneous determination of ascorbic acid, dopamine, and uric acid
    Liwen Xing
    Zhanfang Ma
    Microchimica Acta, 2016, 183 : 257 - 263
  • [24] Voltammetric determination of ascorbic acid with zinc oxide modified glassy carbon electrode
    Nadia Ait Ahmed
    Houa Hammache
    Marielle Eyraud
    Carine Chassigneux
    Florence Vacandio
    Philippe Knauth
    Laid Makhloufi
    Nour-eddine Gabouze
    Journal of the Iranian Chemical Society, 2019, 16 : 1957 - 1963
  • [25] Voltammetric determination of ascorbic acid with zinc oxide modified glassy carbon electrode
    Ahmed, Nadia Ait
    Hammache, Houa
    Eyraud, Marielle
    Chassigneux, Carine
    Vacandio, Florence
    Knauth, Philippe
    Makhloufi, Laid
    Gabouze, Nour-eddine
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2019, 16 (09) : 1957 - 1963
  • [26] Highly Selective Differential Pulse Voltammetric Determination of Uric Acid using Modified Glassy Carbon Electrode
    Movlaee, Kaveh
    Norouzi, Parviz
    Beitollahi, Hadi
    Rezapour, Morteza
    Larijani, Bagher
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (04): : 3241 - 3251
  • [27] A glassy carbon electrode modified with a nanocomposite consisting of MoS2 and reduced graphene oxide for electrochemical simultaneous determination of ascorbic acid, dopamine, and uric acid
    Xing, Liwen
    Ma, Zhanfang
    MICROCHIMICA ACTA, 2016, 183 (01) : 257 - 263
  • [28] Simultaneous determination of uric acid, dopamine and ascorbic acid based on poly(bromocresol green) modified glassy carbon electrode
    Ouyang, Xiaoqian
    Luo, Liqiang
    Ding, Yaping
    Liu, Bingdi
    Xu, Duo
    Huang, Anquan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 748 : 1 - 7
  • [29] Simultaneous Determination of Ascorbic Acid, Dopamine and Uric Acid with Chitosan-Graphene Modified Electrode
    Han, Dongxue
    Han, Tingting
    Shan, Changsheng
    Ivaska, Ari
    Niu, Li
    ELECTROANALYSIS, 2010, 22 (17-18) : 2001 - 2008
  • [30] Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Zare, HR
    Memarzadeh, F
    Mazloum-Ardakani, M
    Namazian, M
    Golabi, SM
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3495 - 3502