A glassy carbon electrode modified with a nanocomposite consisting of MoS2 and reduced graphene oxide for electrochemical simultaneous determination of ascorbic acid, dopamine, and uric acid

被引:123
|
作者
Xing, Liwen [1 ]
Ma, Zhanfang [1 ]
机构
[1] Capital Normal Univ, Dept Chem, Beijing 100048, Peoples R China
基金
北京市自然科学基金;
关键词
MoS2; Cyclic voltammetry; Differential pulse voltammetry; High-resolution transmission electron microscopy; FTIR; Electrochemical sensor; NITROGEN-DOPED GRAPHENE; SELECTIVE DETECTION; HYDROGEN EVOLUTION; SENSOR; NANOPARTICLES; NANOSHEETS; SITES;
D O I
10.1007/s00604-015-1648-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe the synthesis of a hybrid nanocomposite consisting of MoS2 and reduced graphene oxide (MoS2/rGO) by a one-pot hydrothermal process, and the use of the material in an amperometric sensor. Scanning electron microscopy and nitrogen adsorption-desorption tests revealed that the nanocomposite possesses a porous and flower-like structure and a large specific surface. Cyclic voltammetry and differential pulse voltammetry demonstrated the nanocomposite to perform excellently in the electrochemical oxidation of ascorbic acid (AA), dopamine (DA), and uric acid (UA), respectively. The oxidation potentials are well separated (oxidation peaks at -64, 168 and 320 mV vs. Ag/AgCl) for AA, DA, and UA, and the respective detection sensitivities are strongly enhanced (0.12, 4.11 and 1.59 mu A mu M-1 cm(-2)). The sensor was applied to the detection of the three species in spiked human serum samples where it gave recoveries ranging from 98.9 to 104.1 % (for n = 3).
引用
收藏
页码:257 / 263
页数:7
相关论文
共 50 条
  • [1] A glassy carbon electrode modified with a nanocomposite consisting of MoS2 and reduced graphene oxide for electrochemical simultaneous determination of ascorbic acid, dopamine, and uric acid
    Liwen Xing
    Zhanfang Ma
    Microchimica Acta, 2016, 183 : 257 - 263
  • [2] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [3] Simultaneous electrochemical determination of ascorbic acid, dopamine and uric acid based on reduced graphene oxide-Ag/PANI modified glassy carbon electrode
    Zhuo Guo
    Xianke Luo
    Yahui Li
    Dongdi Li
    Qinai Zhao
    Mengmeng Li
    Chi Ma
    Yanting Zhao
    Chemical Research in Chinese Universities, 2017, 33 : 507 - 512
  • [4] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine and Uric Acid Based on Reduced Graphene Oxide-Ag/PANI Modified Glassy Carbon Electrode
    Guo Zhuo
    Luo Xianke
    Li Yahui
    Li Dongdi
    Zhao Qinai
    Li Mengmeng
    Ma Chi
    Zhao Yanting
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2017, 33 (03) : 507 - 512
  • [5] A Facile Electrochemical Fabrication of Reduced Graphene Oxide-Modified Glassy Carbon Electrode for Simultaneous Detection of Dopamine, Ascorbic Acid, and Uric Acid
    Yu, Joonhee
    Kim, Tae Hyun
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2017, 8 (04) : 274 - 281
  • [6] Simultaneous determination of dopamine, ascorbic acid and uric acid at electrochemically reduced graphene oxide modified electrode
    Yang, La
    Liu, Dong
    Huang, Jianshe
    You, Tianyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 166 - 172
  • [7] Modified Glassy Carbon Electrode with Polypyrrole Nanocomposite for the Simultaneous Determination of Ascorbic acid, Dopamine, Uric acid, and Folic Acid
    Ghanbari, Khadijeh
    Bonyadi, Sepideh
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2020, 11 (01) : 68 - 83
  • [8] Simultaneous electrochemical determination of norepinephrine, ascorbic acid and uric acid using a graphene modified glassy carbon electrode
    Xinying Ma
    Mingyong Chao
    Meifeng Chen
    Russian Journal of Electrochemistry, 2014, 50 : 154 - 161
  • [9] Simultaneous electrochemical determination of norepinephrine, ascorbic acid and uric acid using a graphene modified glassy carbon electrode
    Ma, Xinying
    Chao, Mingyong
    Chen, Meifeng
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (02) : 154 - 161
  • [10] Electrochemically synthesized partially reduced graphene oxide modified glassy carbon electrode for individual and simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid
    Aneesh, Padamadathil K.
    Nambiar, Sindhu R.
    Rao, Talasila P.
    Ajayaghosh, Ayyappanpillai
    ANALYTICAL METHODS, 2014, 6 (14) : 5322 - 5330