Highly Selective Differential Pulse Voltammetric Determination of Uric Acid using Modified Glassy Carbon Electrode

被引:22
|
作者
Movlaee, Kaveh [1 ]
Norouzi, Parviz [1 ,2 ]
Beitollahi, Hadi [3 ]
Rezapour, Morteza [4 ]
Larijani, Bagher [5 ]
机构
[1] Univ Tehran, Ctr Excellence Electrochem, Tehran, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Mol Cellular Sci Inst, Biosensor Res Ctr, Tehran, Iran
[3] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman, Iran
[4] Res Inst Petr Ind, IP Dept, POB 14665-137, Tehran, Iran
[5] Univ Tehran Med Sci, Endocrinol & Metab Clin Sci Inst, Diabet Res Ctr, Tehran, Iran
来源
关键词
Uric acid; Fe3O4@SiO2/GO nanocomposite; Graphene; Glassy Carbon Electrode; Differential pulse voltammetry; SOLID-PHASE MICROEXTRACTION; REDUCED GRAPHENE OXIDE; SHELL FE3O4-AT-SIO2/MWCNT NANOCOMPOSITE; HIGH-PERFORMANCE SUPERCAPACITOR; SCREEN-PRINTED ELECTRODE; PASTE ELECTRODE; ASCORBIC-ACID; ELECTROCHEMICAL SENSOR; DRUG-DELIVERY; FOLIC-ACID;
D O I
10.20964/2017.04.06
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A nanocomposite was prepared by incorporating Fe3O4 onto graphene sheets, and then a layer of SiO2 were deposited on the surface of the Fe3O4/graphene composites. This modified electrode was used for electrochemical determination of uric acid (UA). Cyclic voltammetry, differential pulse voltammetry and chronoamperometry were used to investigate the electrochemical behavior of uric acid at the chemically modified electrode. According to the results, Fe3O4@SiO2/GO/GCE showed high electrocatalytic activity for uric acid oxidation, producing a sharp oxidation peak current at 330 mV vs. Ag/AgCl reference electrode at pH 7.0. The peak current was linearly dependent on uric acid concentration over the range of 0.5 to 250.0 mu M with the detection limit (3 sigma) of 0.07 mu M. The proposed method was successfully applied as a rapid, highly selective, simple, and precise one to determine uric acid in urine.
引用
收藏
页码:3241 / 3251
页数:11
相关论文
共 50 条
  • [1] Highly selective determination of ascorbic acid, dopamine, and uric acid by differential pulse voltammetry using poly(sulfonazo III) modified glassy carbon electrode
    Ensafi, Ali A.
    Taei, M.
    Khayamian, T.
    Arabzadeh, A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 147 (01): : 213 - 221
  • [2] Highly selective determination of ascorbic acid, epinephrine, and uric acid by differential pulse voltammetry using poly(Adizol Black B)-modified glassy carbon electrode
    M. Taei
    M. Jamshidi
    Journal of Solid State Electrochemistry, 2014, 18 : 673 - 683
  • [3] Highly selective determination of ascorbic acid, epinephrine, and uric acid by differential pulse voltammetry using poly(Adizol Black B)-modified glassy carbon electrode
    Taei, M.
    Jamshidi, M.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (03) : 673 - 683
  • [4] Differential pulse voltammetric determination of uric acid on carbon-coated iron nanoparticle modified glassy carbon electrodes
    Wang, Shengfu
    Xu, Qiao
    Liu, Guodong
    ELECTROANALYSIS, 2008, 20 (10) : 1116 - 1120
  • [5] Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid by Differential Pulse Voltammetry using Tiron Modified Glassy Carbon Electrode
    Ensafi, Ali A.
    Taei, M.
    Khayamian, Taghi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (01): : 116 - 130
  • [6] Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups
    Wu, Feng
    Huang, Ting
    Hu, Yangjian
    Yang, Xin
    Ouyang, Yuejun
    Xie, Qingji
    MICROCHIMICA ACTA, 2016, 183 (09) : 2539 - 2546
  • [7] Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups
    Feng Wu
    Ting Huang
    Yangjian Hu
    Xin Yang
    Yuejun Ouyang
    Qingji Xie
    Microchimica Acta, 2016, 183 : 2539 - 2546
  • [8] Differential pulse voltammetric determination of hexavalent chromium using nickel hexacyanoferrate modified glassy carbon electrode
    Dinbore, Wendimagegn T.
    Dabbo, Wolde C.
    Washe, Aemayehu P.
    SUSTAINABLE ENVIRONMENT, 2021, 7 (01):
  • [9] Voltammetric determination of uric acid at a fullerene-C60-modified glassy carbon electrode
    Goyal, RN
    Gupta, VK
    Sangal, A
    Bachheti, N
    ELECTROANALYSIS, 2005, 17 (24) : 2217 - 2223
  • [10] Differential Pulse Voltammetric Determination of Folic Acid in the Presence of Ascorbic Acid using A Glassy Carbon Electrode Modified with Reduced Graphene Oxide
    Abd-Elsabour, Mohamed
    Toghan, Arafat
    Abo-bakr, Ahmed M.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (08): : 789 - 805