Disposable amperometric biosensor for the determination of tyramine using plasma amino oxidase

被引:1
|
作者
Ana Calvo-Pérez
Olga Domínguez-Renedo
María Asunción Alonso-Lomillo
María Julia Arcos-Martínez
机构
[1] University of Burgos,Department of Chemistry, Faculty of Sciences
来源
Microchimica Acta | 2013年 / 180卷
关键词
Biogenic amines; PAO; Biosensor; Screen-printed electrodes; Tyramine;
D O I
暂无
中图分类号
学科分类号
摘要
We have developed screen–printed carbon electrodes for the determination of tyramine (Tyr) via plasma amine oxidase. The enzyme was immobilized on the carbon working electrode by cross–linking it with bovine serum albumin using glutaraldehyde. The employment of the mediator hydroxymethylferrocene lowers the working potential to +260 mV (vs. a screen–printed Ag/AgCl reference electrode). The effects of pH, potential and mediator concentration were optimized and resulted in reproducibility and repeatability values of 8.6 % and 8.7 %, respectively. Response is linear in the range from 2 to 164 μM, and the limit of detection is 2.0 ± 0.18 μM. The effects of potentially interfering biogenic amines such as putrescine, cadaverine, histamine, spermine, spermidine and tryptamine were also evaluated. The biosensor was successfully applied to the determination of Tyr in cheese.
引用
收藏
页码:253 / 259
页数:6
相关论文
共 50 条
  • [41] Determination of Putrescine in Tiger Prawn Using an Amperometric Biosensor Based on Immobilization of Diamine Oxidase onto Ceria Nanospheres
    Manju Bhargavi Gumpu
    Noel Nesakumar
    Swaminathan Sethuraman
    Uma Maheswari Krishnan
    John Bosco Balaguru Rayappan
    Food and Bioprocess Technology, 2016, 9 : 717 - 724
  • [42] Amperometric determination of choline released from rat submandibular gland acinar cells using a choline oxidase biosensor
    Razola, SS
    Pochet, S
    Grosfils, K
    Kauffmann, JM
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3): : 185 - 191
  • [43] Determination of total creatine kinase activity in blood serum using an amperometric biosensor based on glucose oxidase and hexokinase
    Kucherenko, I. S.
    Soldatkin, O. O.
    Lagarde, F.
    Jaffrezic-Renault, N.
    Dzyadevych, S. V.
    Soldatkin, A. P.
    TALANTA, 2015, 144 : 604 - 611
  • [44] An amperometric biosensor for xanthine determination prepared from xanthine oxidase immobilized in polypyrrole film
    Arslan, F
    Yasar, A
    Kiliç, E
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2006, 34 (01): : 113 - 128
  • [45] Determination of phenolic compounds by a polyphenol oxidase amperometric biosensor and artificial neural network analysis
    Gutés, A
    Céspedes, F
    Alegret, S
    del Valle, M
    BIOSENSORS & BIOELECTRONICS, 2005, 20 (08): : 1668 - 1673
  • [46] Disposable Electrochemical Biosensor for Amperometric Measurement of β-hydroxybutyrate and Total Cholesterol
    Huaqing Li Li Wang Nenggao Rao Dafu Cui Xinxia Cai State Key Laboratory of Transducer TechnologyInstitute of ElectronicsChinese Academy of SciencesBeijing China Graduate School of Chinese Academy of ScienceBeijing China
    稀有金属材料与工程, 2006, (S3) : 305 - 308
  • [47] A disposable amperometric biosensor for determining total cholesterol in whole blood
    Fang, Cheng
    He, Jishan
    Chen, Zhencheng
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02): : 545 - 550
  • [48] Amperometric biosensor based on polypyrrole and tyrosinase for the detection of tyramine in food samples
    Apetrei, Irina Mirela
    Apetrei, Constantin
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 40 - 46
  • [49] Disposable amperometric biosensor based on nanostructured bacteriophages for glucose detection
    Kang, Yu Ri
    Hwang, Kyung Hoon
    Kim, Ju Hwan
    Nam, Chang Hoon
    Kim, Soo Won
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (10)
  • [50] Disposable electrochemical biosensor for amperometric measurement of β-hydroxybutyrate and total cholesterol
    Li, Huaqing
    Wang, Li
    Rao, Nenggao
    Cui, Dafu
    Cai, Xinxia
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 305 - 308