Disposable amperometric biosensor for the determination of tyramine using plasma amino oxidase

被引:1
|
作者
Ana Calvo-Pérez
Olga Domínguez-Renedo
María Asunción Alonso-Lomillo
María Julia Arcos-Martínez
机构
[1] University of Burgos,Department of Chemistry, Faculty of Sciences
来源
Microchimica Acta | 2013年 / 180卷
关键词
Biogenic amines; PAO; Biosensor; Screen-printed electrodes; Tyramine;
D O I
暂无
中图分类号
学科分类号
摘要
We have developed screen–printed carbon electrodes for the determination of tyramine (Tyr) via plasma amine oxidase. The enzyme was immobilized on the carbon working electrode by cross–linking it with bovine serum albumin using glutaraldehyde. The employment of the mediator hydroxymethylferrocene lowers the working potential to +260 mV (vs. a screen–printed Ag/AgCl reference electrode). The effects of pH, potential and mediator concentration were optimized and resulted in reproducibility and repeatability values of 8.6 % and 8.7 %, respectively. Response is linear in the range from 2 to 164 μM, and the limit of detection is 2.0 ± 0.18 μM. The effects of potentially interfering biogenic amines such as putrescine, cadaverine, histamine, spermine, spermidine and tryptamine were also evaluated. The biosensor was successfully applied to the determination of Tyr in cheese.
引用
收藏
页码:253 / 259
页数:6
相关论文
共 50 条
  • [31] Amine oxidase amperometric biosensor coupled to liquid chromatography for biogenic amines determination
    Muresan, Laura
    Valera, Ruben Ronda
    Frebort, Ivo
    Popescu, Ionel Catalin
    Csoregi, Elisabeth
    Nistor, Mihaela
    MICROCHIMICA ACTA, 2008, 163 (3-4) : 219 - 225
  • [32] Accurate glutamate monitoring in foodstuffs by a sensitive and interference-free glutamate oxidase based disposable amperometric biosensor
    Mentana, Annalisa
    Nardiello, Donatella
    Palermo, Carmen
    Centonze, Diego
    ANALYTICA CHIMICA ACTA, 2020, 1115 : 16 - 22
  • [33] Amperometric biosensor for total histamine, putrescine and cadaverine using diamine oxidase
    Male, KB
    Bouvrette, P
    Luong, JHT
    Gibbs, BF
    JOURNAL OF FOOD SCIENCE, 1996, 61 (05) : 1012 - 1016
  • [34] Accurate glutamate monitoring in foodstuffs by a sensitive and interference-free glutamate oxidase based disposable amperometric biosensor
    Mentana, Annalisa
    Nardiello, Donatella
    Palermo, Carmen
    Centonze, Diego
    Analytica Chimica Acta, 2020, 1115 : 16 - 22
  • [35] Amperometric biosensor for the determination of creatine
    A. Ramanavicius
    Analytical and Bioanalytical Chemistry, 2007, 387 : 1899 - 1906
  • [36] Amperometric Biosensor for Phenol Determination
    da Costa Silva, Livia Maria
    Salgado, Andrea Medeiros
    Zarur Coelho, Maria Alice
    ICHEAP-10: 10TH INTERNATIONAL CONFERENCE ON CHEMICAL AND PROCESS ENGINEERING, PTS 1-3, 2011, 24 : 1249 - +
  • [37] Amperometric biosensor for the determination of creatine
    Ramanavicius, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (05) : 1899 - 1906
  • [38] Rutin determination at an amperometric biosensor
    Mousty, Christine
    Cosnier, Serge
    Lopez, Marta Sanchez-Paniagua
    Lopez-Cabarcos, Enrique
    Lopez-Ruiz, Beatriz
    ELECTROANALYSIS, 2007, 19 (2-3) : 253 - 258
  • [39] Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane
    Brahim, S
    Narinesingh, D
    Guiseppi-Elie, A
    ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) : 27 - 36
  • [40] Determination of Putrescine in Tiger Prawn Using an Amperometric Biosensor Based on Immobilization of Diamine Oxidase onto Ceria Nanospheres
    Gumpu, Manju Bhargavi
    Nesakumar, Noel
    Sethuraman, Swaminathan
    Krishnan, Uma Maheswari
    Rayappan, John Bosco Balaguru
    FOOD AND BIOPROCESS TECHNOLOGY, 2016, 9 (04) : 717 - 724