Disposable amperometric biosensor for the determination of tyramine using plasma amino oxidase

被引:1
|
作者
Ana Calvo-Pérez
Olga Domínguez-Renedo
María Asunción Alonso-Lomillo
María Julia Arcos-Martínez
机构
[1] University of Burgos,Department of Chemistry, Faculty of Sciences
来源
Microchimica Acta | 2013年 / 180卷
关键词
Biogenic amines; PAO; Biosensor; Screen-printed electrodes; Tyramine;
D O I
暂无
中图分类号
学科分类号
摘要
We have developed screen–printed carbon electrodes for the determination of tyramine (Tyr) via plasma amine oxidase. The enzyme was immobilized on the carbon working electrode by cross–linking it with bovine serum albumin using glutaraldehyde. The employment of the mediator hydroxymethylferrocene lowers the working potential to +260 mV (vs. a screen–printed Ag/AgCl reference electrode). The effects of pH, potential and mediator concentration were optimized and resulted in reproducibility and repeatability values of 8.6 % and 8.7 %, respectively. Response is linear in the range from 2 to 164 μM, and the limit of detection is 2.0 ± 0.18 μM. The effects of potentially interfering biogenic amines such as putrescine, cadaverine, histamine, spermine, spermidine and tryptamine were also evaluated. The biosensor was successfully applied to the determination of Tyr in cheese.
引用
收藏
页码:253 / 259
页数:6
相关论文
共 50 条
  • [11] An amperometric biosensor for determining amino acids using a bienzymatic system containing amino acid oxidase and protease
    Kwan, RCH
    Chan, CY
    Renneberg, R
    BIOTECHNOLOGY LETTERS, 2002, 24 (14) : 1203 - 1207
  • [12] An amperometric biosensor for determining amino acids using a bienzymatic system containing amino acid oxidase and protease
    Roger C.H. Kwan
    Chiyui Chan
    Reinhard Renneberg
    Biotechnology Letters, 2002, 24 : 1203 - 1207
  • [13] The fabrication and optimization of the disposable amperometric biosensor
    Tu, YF
    Fu, ZQ
    Chen, HY
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 80 (02) : 101 - 105
  • [14] Development of disposable amperometric cholesterol biosensor
    Wang, Xiaohao
    Tang, Fei
    Xu, Xiaowen
    Chen, Zhencheng
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 321 - 323
  • [15] Development of Disposable Amperometric Cholesterol Biosensor
    Xiaohao Wang Fei Tang Xiaowen Xu Zhencheng Chen State Key Laboratory of Precision Measurement Technology and InstrumentsTsinghua UniversityBeijing China
    稀有金属材料与工程, 2006, (S3) : 321 - 323
  • [16] Disposable amperometric magnetoimmunosensors using nanobodies as biorecognition element. Determination of fibrinogen in plasma
    Campuzano, S.
    Salema, V.
    Moreno-Guzman, M.
    Gamella, M.
    Yanez-Sedeno, P.
    Fernandez, L. A.
    Pingarron, J. M.
    BIOSENSORS & BIOELECTRONICS, 2014, 52 : 255 - 260
  • [17] Determination of serum alcohol using a disposable biosensor
    Luo, Peng
    Liu, Yi
    Xie, Guoming
    Xiong, Xingliang
    Deng, Shixiong
    Song, Fangzhou
    FORENSIC SCIENCE INTERNATIONAL, 2008, 179 (2-3) : 192 - 198
  • [18] Amperometric determination of lysine using a lysine oxidase biosensor based on rigid-conducting composites
    Saurina, J
    Hernández-Cassou, S
    Alegret, S
    Fàbregas, E
    BIOSENSORS & BIOELECTRONICS, 1999, 14 (02): : 211 - 220
  • [19] Ascorbic Acid Determination by an Amperometric Ascorbate Oxidase-based Biosensor
    Pisoschi, Aurelia-Magdalena
    Negulescu, Gheorghe-Petre
    Pisoschi, Aurel
    REVISTA DE CHIMIE, 2010, 61 (04): : 339 - 344
  • [20] Disposable biosensor based on ionic liquid, carbon nanofiber and poly (glutamic acid) for tyramine determination
    Kocoglu, Irem Okman
    Erden, Pinar Esra
    Kilic, Esma
    ANALYTICAL BIOCHEMISTRY, 2024, 684