Nafion-graphene composite film modified glassy carbon electrode for voltammetric determination of p-aminophenol

被引:0
|
作者
Hayati Filik
Gamze Çetintaş
Serkan Naci Koç
Handan Gülce
İsmail Boz
机构
[1] Istanbul University,Faculty of Engineering, Department of Chemistry
[2] Istanbul University,Faculty of Engineering, Department of Chemical Engineering
[3] Selçuk University,Department of Chemical Engineering
来源
关键词
-aminophenol; paracetamol; voltammetry; graphene; urine analysis; pharmaceutical analysis;
D O I
暂无
中图分类号
学科分类号
摘要
A Nafion-graphene (Nafion-GR) nanocomposite film modified glassy carbon electrode was fabricated by a simple drop-casting method, and used in the electrochemical detection of p-aminophenol (4-AP). Owing to the large surface area, good conductivity of GR and good affinity of Nafion, the sensor exhibited excellent electrocatalytic activity for the oxidation of 4-AP. The electrochemical behaviors of 4-AP on Nafion/GR film modified glassy carbon electrodes were investigated by cyclic voltammetry and differential pulse voltammetry. A calibration curve is constructed in the same matrix, urine, as the unknown samples to be analyzed. The Nafion-GR film modified electrode was linearly dependent on the 4-AP concentration and the linear analytical curve was obtained in the ranges of 0.5–200 μM with differential pulse voltammetry (DPV) and the detection limit was 0.051 μM. The Nafion-graphene nanocomposite modified electrode exhibited good reusability than pure graphene modified GCE. This procedure can be used for the determination of p-aminophenol in the presence of its degradation products and paracetamol. Finally, the proposed method was successfully used to determine p-aminophenol in local tap water samples in urine samples and pharmaceutical preparations.
引用
收藏
页码:243 / 252
页数:9
相关论文
共 50 条
  • [1] Nafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol
    Filik, Hayati
    Cetintas, Gamze
    Koc, Serkan Naci
    Gulce, Handan
    Boz, Ismail
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (03) : 243 - 252
  • [2] Voltammetric Determination of Sumatriptan by an Overoxidized Poly(p-aminophenol) Modified Glassy Carbon Electrode
    Jalali-Sarvestani, Mohammad Reza
    Madrakian, Tayyebeh
    Afkhami, Abbas
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2021, 8 (03): : 245 - 259
  • [3] Voltammetric determination of sumatriptan based on a graphene/gold nanoparticles/Nafion composite modified glassy carbon electrode
    Sanghavi, Bankim J.
    Kalambate, Pramod K.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    TALANTA, 2014, 120 : 1 - 9
  • [4] Electrochemical behavior and voltammetric determination of 4-aminophenol based on graphene-chitosan composite film modified glassy carbon electrode
    Yin, Huanshun
    Ma, Qiang
    Zhou, Yunlei
    Ai, Shiyun
    Zhu, Lusheng
    ELECTROCHIMICA ACTA, 2010, 55 (23) : 7102 - 7108
  • [5] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Li, Yamin
    Wu, Shufang
    Luo, Peili
    Liu, Jie
    Song, Ge
    Zhang, Kai
    Ye, Baoxian
    ANALYTICAL SCIENCES, 2012, 28 (05) : 497 - 502
  • [6] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Yamin Li
    Shufang Wu
    Peili Luo
    Jie Liu
    Ge Song
    Kai Zhang
    Baoxian Ye
    Analytical Sciences, 2012, 28 : 497 - 502
  • [7] Graphene-Nafion Composite Film Modified Electrode for Voltammetric Sensor for Determination of Dihydromyricetin
    Wang, Fei
    Yu, Xiang
    Li, Haojie
    Li, Ming
    Feng, Qimin
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2013, 60 (08) : 1019 - 1026
  • [8] Simultaneous voltammetric determination of paracetamol and domperidone based on a graphene/platinum nanoparticles/nafion composite modified glassy carbon electrode
    Kalambate, Pramod K.
    Sanghavi, Bankim J.
    Karna, Shashi P.
    Srivastava, Ashwini K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 285 - 294
  • [9] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015
  • [10] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Suling Yang
    Ran Yang
    Gang Li
    Jianjun Li
    Lingbo Qu
    Journal of Chemical Sciences, 2010, 122 : 919 - 926