Electrochemical behavior and voltammetric determination of 4-aminophenol based on graphene-chitosan composite film modified glassy carbon electrode

被引:207
|
作者
Yin, Huanshun [1 ,2 ]
Ma, Qiang [1 ]
Zhou, Yunlei [1 ]
Ai, Shiyun [1 ]
Zhu, Lusheng [2 ]
机构
[1] Shandong Agr Univ, Coll Chem & Mat Sci, Tai An 271018, Shandong, Peoples R China
[2] Shandong Agr Univ, Coll Resources & Environm, Tai An 271018, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Graphene; 4-Aminophenol; Electrochemical oxidation; Kinetic parameter; Determination; P-AMINOPHENOL; SPECTROPHOTOMETRIC DETERMINATION; ADSORPTION; SENSOR; OXIDE;
D O I
10.1016/j.electacta.2010.06.072
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The graphene-chitosan composite film modified glassy carbon electrode (GCE) was fabricated and used to determine 4-aminophenol (4-AP). In 0.1 M pH 6.3 phosphate buffer solution, the redox peak currents of 4-AP increased significantly and the peak-to-peak separation decreased greatly at graphene-chitosan composite film modified GCE compared with bare GCE and chitosan modified GCE, indicating that graphene possessed electrocatalytic activity towards 4-AP. The experimental conditions were optimized and the kinetic parameters were investigated. The oxidation mechanism was discussed. Under the optimal experimental conditions, the oxidation peak current was proportional to 4-AP concentration in the range from 0.2 to 550 mu M with the correlation coefficient of 0.9930. The detection limit was 0.057 mu M (S/N = 3). Using the proposed method, 4-AP was successfully determined in water samples and paracetamol tablets with standard addition method, suggesting that this method can be applied to determine 4-AP in environments and pharmaceuticals. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:7102 / 7108
页数:7
相关论文
共 50 条
  • [1] Graphene-polyaniline composite film modified electrode for voltammetric determination of 4-aminophenol
    Fan, Yang
    Liu, Jin-Hang
    Yang, Chun-Peng
    Yu, Meng
    Liu, Peng
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02): : 669 - 674
  • [2] Electrochemical Determination of 4-Nonylphenol Based on Graphene-Chitosan Modified Glassy Carbon Electrode
    Zhou Wen-Shu
    Zhao Bo
    Huang Xiao-Hua
    Yang Xiao-Di
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (05) : 675 - 680
  • [3] Electrochemical behavior of catechol, resorcinol and hydroquinone at graphene-chitosan composite film modified glassy carbon electrode and their simultaneous determination in water samples
    Yin, Huanshun
    Zhang, Qingming
    Zhou, Yunlei
    Ma, Qiang
    Liu, Tao
    Zhu, Lusheng
    Ai, Shiyun
    ELECTROCHIMICA ACTA, 2011, 56 (06) : 2748 - 2753
  • [4] Nafion-graphene composite film modified glassy carbon electrode for voltammetric determination of p-aminophenol
    Hayati Filik
    Gamze Çetintaş
    Serkan Naci Koç
    Handan Gülce
    İsmail Boz
    Russian Journal of Electrochemistry, 2014, 50 : 243 - 252
  • [5] Nafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol
    Filik, Hayati
    Cetintas, Gamze
    Koc, Serkan Naci
    Gulce, Handan
    Boz, Ismail
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (03) : 243 - 252
  • [6] Voltammetric determination of immunosuppressive agent, azathioprine, by using a graphene-chitosan modified-glassy carbon electrode
    Zahra Hatami
    Fahimeh Jalali
    Russian Journal of Electrochemistry, 2015, 51 : 70 - 76
  • [7] Voltammetric Determination of Immunosuppressive Agent, Azathioprine, by Using a Graphene-Chitosan Modified-Glassy Carbon Electrode
    Hatami, Zahra
    Jalali, Fahimeh
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2015, 51 (01) : 70 - 76
  • [8] Electrocatalytical oxidation and sensitive determination of acetaminophen on glassy carbon electrode modified with graphene-chitosan composite
    Zheng, Meixia
    Gao, Feng
    Wang, Qingxiang
    Cai, Xili
    Jiang, Shulian
    Huang, Lizhang
    Gao, Fei
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (03): : 1514 - 1520
  • [9] Electrochemical behavior and voltammetric determination of ammonium dinitramide using a graphene film modified glassy carbon electrode
    Najafi, Mostafa
    Darabi, Salman
    ELECTROCHIMICA ACTA, 2014, 121 : 315 - 320
  • [10] Electrochemical behavior of phenacetin on CdSe microspheres modified glassy carbon electrode and its simultaneous determination with paracetamol and 4-aminophenol
    Yin, Huanshun
    Meng, Xiaomeng
    Xu, Zhenning
    Chen, Lijian
    Ai, Shiyun
    ANALYTICAL METHODS, 2012, 4 (05) : 1445 - 1451