Voltammetric Determination of Sumatriptan by an Overoxidized Poly(p-aminophenol) Modified Glassy Carbon Electrode

被引:0
|
作者
Jalali-Sarvestani, Mohammad Reza [1 ]
Madrakian, Tayyebeh [1 ]
Afkhami, Abbas [1 ,2 ]
机构
[1] Bu Ali Sina Univ, Fac Chem, Hamadan, Hamadan, Iran
[2] D8 Int Univ, Hamadan, Hamadan, Iran
来源
关键词
Sumatriptan; Square wave voltammetry; Poly(4-aminophenol); Glassy carbon electrode; SQUARE-WAVE VOLTAMMETRY; ELECTROCHEMICAL DETERMINATION; ASCORBIC-ACID; HUMAN SERUM; URIC-ACID; SENSOR; DOPAMINE; NANOPARTICLES; ZOLMITRIPTAN; RIZATRIPTAN;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study aims to develop a promising electrochemical sensor based on polymer film overoxidation following the electrochemical polymerization of p-aminophenol on a bare glassy carbon electrode (GCE) surface for the voltammetric determination of sumatriptan succinate (SUM). Cyclic voltammetry (CV), Fourier-transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) and square wave voltammetry (SWV) were employed to characterize the electroanalytical performance and morphology of the modified electrode. The results indicated a significant improvement in electrode sensitivity to SUM after electrochemical polymerization and overoxidation of poly(p-aminophenol). We also investigated the effect of all effective instrumental and experimental parameters on sensor response. Under the optimum conditions (accumulation for 60 s at 0.055 V and pH = 2.0), the electrode SWV response to SUM within the range of 1.0-100.0 mu M with a limit of detection (LOD) of 0.294 mu M was linear under optimized conditions. We also evaluated the selectivity of the designed sensor to different interfering species, suggesting no significant interference. The designed sensor was also used to determine SUM in pharmaceutical preparations and human serum samples with minimal matrix effects, admissible recoveries (99-106), and satisfactory repeatability (1.2-5.1 %RSD). The proposed sensor exhibited admissible repeatability, reproducibility, and stability.
引用
收藏
页码:245 / 259
页数:15
相关论文
共 50 条
  • [1] Nafion-graphene composite film modified glassy carbon electrode for voltammetric determination of p-aminophenol
    Hayati Filik
    Gamze Çetintaş
    Serkan Naci Koç
    Handan Gülce
    İsmail Boz
    Russian Journal of Electrochemistry, 2014, 50 : 243 - 252
  • [2] Nafion-Graphene Composite Film Modified Glassy Carbon Electrode for Voltammetric Determination of p-Aminophenol
    Filik, Hayati
    Cetintas, Gamze
    Koc, Serkan Naci
    Gulce, Handan
    Boz, Ismail
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (03) : 243 - 252
  • [3] Simultaneous determination of N-acetyl-p-aminophenol and p-aminophenol with poly(3,4-ethylenedioxythiophene) modified glassy carbon electrode
    Mehretie, Solomon
    Admassie, Shimelis
    Hunde, Tadele
    Tessema, Mend
    Solomon, Theodros
    TALANTA, 2011, 85 (03) : 1376 - 1382
  • [4] Voltammetric behavior and determination of isoniazid in pharmaceuticals by using overoxidized polypyrrole glassy carbon modified electrode
    Majidi, MR
    Jouyban, A
    Asadpour-Zeynali, K
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 589 (01) : 32 - 37
  • [5] Facile longitudinal unzipped multiwalled carbon nanotubes incorporated overoxidized poly(p-aminophenol) modified electrode for sensitive simultaneous determination of dopamine, uric acid and tryptophan
    Wang, Cun
    Xiong, Zhengwei
    Sun, Peng
    Wang, Rui
    Zhao, Xin
    Wang, Qiang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 801 : 395 - 402
  • [6] Electrochemical Determination of Dicofol at Nickel Nanowire Modified Poly(p-aminophenol) Film Electrode
    Karabiberoglu, Sukriye Ulubay
    Kocak, Cagri Ceylan
    Dursun, Zekerya
    ELECTROANALYSIS, 2019, 31 (07) : 1304 - 1310
  • [7] Voltammetric determination of levofloxacin using a glassy carbon electrode modified with poly(o-aminophenol) and graphene quantum dots
    Jing-Yi Huang
    Ting Bao
    Tian-Xing Hu
    Wei Wen
    Xiu-Hua Zhang
    Sheng-Fu Wang
    Microchimica Acta, 2017, 184 : 127 - 135
  • [8] Voltammetric determination of levofloxacin using a glassy carbon electrode modified with poly(o-aminophenol) and graphene quantum dots
    Huang, Jing-Yi
    Bao, Ting
    Hu, Tian-Xing
    Wen, Wei
    Zhang, Xiu-Hua
    Wang, Sheng-Fu
    MICROCHIMICA ACTA, 2017, 184 (01) : 127 - 135
  • [9] SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF p-AMINOPHENOL AND PARACETAMOL USING ACTIVATED GLASSY CARBON ELECTRODE: CYCLIC VOLTAMMETRY AND DIFFERENTIAL PULSE VOLTAMMETRY STUDY
    Tikuye, Teklu
    Feyisa, Tilahun Yai
    Kitte, Shimeles Addisu
    Gebretsadik, Gebru
    Yenealem, Dereje
    ACTA CHEMICA IASI, 2020, 28 (02) : 146 - 162
  • [10] Electrocatalytic determination of 6-tioguanine at a p-aminophenol modified carbon paste electrode
    Mirmomtaz, Elham
    Ensafi, Ali Asghar
    Karimi-Maleh, Hassan
    ELECTROANALYSIS, 2008, 20 (18) : 1973 - 1979