Voltammetric Determination of Sumatriptan by an Overoxidized Poly(p-aminophenol) Modified Glassy Carbon Electrode

被引:0
|
作者
Jalali-Sarvestani, Mohammad Reza [1 ]
Madrakian, Tayyebeh [1 ]
Afkhami, Abbas [1 ,2 ]
机构
[1] Bu Ali Sina Univ, Fac Chem, Hamadan, Hamadan, Iran
[2] D8 Int Univ, Hamadan, Hamadan, Iran
来源
关键词
Sumatriptan; Square wave voltammetry; Poly(4-aminophenol); Glassy carbon electrode; SQUARE-WAVE VOLTAMMETRY; ELECTROCHEMICAL DETERMINATION; ASCORBIC-ACID; HUMAN SERUM; URIC-ACID; SENSOR; DOPAMINE; NANOPARTICLES; ZOLMITRIPTAN; RIZATRIPTAN;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study aims to develop a promising electrochemical sensor based on polymer film overoxidation following the electrochemical polymerization of p-aminophenol on a bare glassy carbon electrode (GCE) surface for the voltammetric determination of sumatriptan succinate (SUM). Cyclic voltammetry (CV), Fourier-transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) and square wave voltammetry (SWV) were employed to characterize the electroanalytical performance and morphology of the modified electrode. The results indicated a significant improvement in electrode sensitivity to SUM after electrochemical polymerization and overoxidation of poly(p-aminophenol). We also investigated the effect of all effective instrumental and experimental parameters on sensor response. Under the optimum conditions (accumulation for 60 s at 0.055 V and pH = 2.0), the electrode SWV response to SUM within the range of 1.0-100.0 mu M with a limit of detection (LOD) of 0.294 mu M was linear under optimized conditions. We also evaluated the selectivity of the designed sensor to different interfering species, suggesting no significant interference. The designed sensor was also used to determine SUM in pharmaceutical preparations and human serum samples with minimal matrix effects, admissible recoveries (99-106), and satisfactory repeatability (1.2-5.1 %RSD). The proposed sensor exhibited admissible repeatability, reproducibility, and stability.
引用
收藏
页码:245 / 259
页数:15
相关论文
共 50 条
  • [21] Simultaneous voltammetric determination of guanine and adenine by using a glassy carbon electrode modified with a composite consisting of carbon quantum dots and overoxidized poly(2-aminopyridine)
    Shaoying He
    Ping He
    Xiaojuan Zhang
    Xingquan Zhang
    Faqin Dong
    Lingpu Jia
    Licheng Du
    Hong Lei
    Microchimica Acta, 2018, 185
  • [22] Simultaneous voltammetric determination of guanine and adenine by using a glassy carbon electrode modified with a composite consisting of carbon quantum dots and overoxidized poly(2-aminopyridine)
    He, Shaoying
    He, Ping
    Zhang, Xiaojuan
    Zhang, Xingquan
    Dong, Faqin
    Jia, Lingpu
    Du, Licheng
    Lei, Hong
    MICROCHIMICA ACTA, 2018, 185 (02)
  • [23] Voltammetric sensitive determination of metronidazole at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Saglikoglu, Gulsen
    Yilmaz, Selehattin
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2015, 51 (09) : 862 - 866
  • [24] Poly(2,2′-(1,4-phenylenedivinylene) Bis-8-hydroxyquinaldine) Modified Glassy Carbon Electrode for the Simultaneous Determination of Paracetamol and p-Aminophenol
    Filik, Hayati
    Aydar, Sevda
    Avan, Asiye Aslihan
    ANALYTICAL LETTERS, 2015, 48 (16) : 2581 - 2596
  • [25] Voltammetric sensitive determination of metronidazole at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Gulsen Saglikoglu
    Selehattin Yilmaz
    Russian Journal of Electrochemistry, 2015, 51 : 862 - 866
  • [26] Simultaneous determination of paracetamol and p-aminophenol using glassy carbon electrode modified with nitrogen- and sulfur- co-doped carbon dots
    Wang, Jingjing
    Zhang, Hua
    Zhao, Junhong
    Zhang, Ruyue
    Zhao, Na
    Ren, Hailong
    Li, Yingchun
    MICROCHIMICA ACTA, 2019, 186 (11)
  • [27] Simultaneous determination of paracetamol and p-aminophenol using glassy carbon electrode modified with nitrogen- and sulfur- co-doped carbon dots
    Jingjing Wang
    Hua Zhang
    Junhong Zhao
    Ruyue Zhang
    Na Zhao
    Hailong Ren
    Yingchun Li
    Microchimica Acta, 2019, 186
  • [28] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [29] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [30] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Surface Engineering and Applied Electrochemistry, 2024, 60 : 15 - 23