Nafion-graphene composite film modified glassy carbon electrode for voltammetric determination of p-aminophenol

被引:0
|
作者
Hayati Filik
Gamze Çetintaş
Serkan Naci Koç
Handan Gülce
İsmail Boz
机构
[1] Istanbul University,Faculty of Engineering, Department of Chemistry
[2] Istanbul University,Faculty of Engineering, Department of Chemical Engineering
[3] Selçuk University,Department of Chemical Engineering
来源
关键词
-aminophenol; paracetamol; voltammetry; graphene; urine analysis; pharmaceutical analysis;
D O I
暂无
中图分类号
学科分类号
摘要
A Nafion-graphene (Nafion-GR) nanocomposite film modified glassy carbon electrode was fabricated by a simple drop-casting method, and used in the electrochemical detection of p-aminophenol (4-AP). Owing to the large surface area, good conductivity of GR and good affinity of Nafion, the sensor exhibited excellent electrocatalytic activity for the oxidation of 4-AP. The electrochemical behaviors of 4-AP on Nafion/GR film modified glassy carbon electrodes were investigated by cyclic voltammetry and differential pulse voltammetry. A calibration curve is constructed in the same matrix, urine, as the unknown samples to be analyzed. The Nafion-GR film modified electrode was linearly dependent on the 4-AP concentration and the linear analytical curve was obtained in the ranges of 0.5–200 μM with differential pulse voltammetry (DPV) and the detection limit was 0.051 μM. The Nafion-graphene nanocomposite modified electrode exhibited good reusability than pure graphene modified GCE. This procedure can be used for the determination of p-aminophenol in the presence of its degradation products and paracetamol. Finally, the proposed method was successfully used to determine p-aminophenol in local tap water samples in urine samples and pharmaceutical preparations.
引用
收藏
页码:243 / 252
页数:9
相关论文
共 50 条
  • [31] Electrocatalytic determination of 6-tioguanine at a p-aminophenol modified carbon paste electrode
    Mirmomtaz, Elham
    Ensafi, Ali Asghar
    Karimi-Maleh, Hassan
    ELECTROANALYSIS, 2008, 20 (18) : 1973 - 1979
  • [32] Electrochemical behavior and voltammetric determination of ammonium dinitramide using a graphene film modified glassy carbon electrode
    Najafi, Mostafa
    Darabi, Salman
    ELECTROCHIMICA ACTA, 2014, 121 : 315 - 320
  • [33] VOLTAMMETRIC DETERMINATION OF METHYLPARABAN IN COSMETICS USING A MULTI-WALL CARBON NANOTUBES/NAFION COMPOSITE MODIFIED GLASSY CARBON ELECTRODE
    Luo, Peili
    Liu, Jie
    Li, Yamin
    Miao, Yurui
    Ye, Baoxian
    ANALYTICAL LETTERS, 2012, 45 (16) : 2445 - 2454
  • [34] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Palanisamy, Selvakumar
    Ramaraj, Sayee Kannan
    Chen, Shen-Ming
    Velusamy, Vijayalakshmi
    Yang, Thomas C. K.
    Chen, Tse-Wei
    MICROCHIMICA ACTA, 2017, 184 (04) : 1051 - 1057
  • [35] Voltammetric determination of catechol based on a glassy carbon electrode modified with a composite consisting of graphene oxide and polymelamine
    Selvakumar Palanisamy
    Sayee Kannan Ramaraj
    Shen-Ming Chen
    Vijayalakshmi Velusamy
    Thomas C. K. Yang
    Tse-Wei Chen
    Microchimica Acta, 2017, 184 : 1051 - 1057
  • [36] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Biljana Nigović
    Ana Mornar
    Miranda Sertić
    Microchimica Acta, 2016, 183 : 1459 - 1467
  • [37] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Nigovic, Biljana
    Mornar, Ana
    Sertic, Miranda
    MICROCHIMICA ACTA, 2016, 183 (04) : 1459 - 1467
  • [38] Electrochemical oxidation behavior of colchicine on a graphene oxide-Nafion composite film modified glassy carbon electrode
    Wang, Fei
    Zhou, Jing
    Liu, Yang
    Wu, ShengJiang
    Song, Ge
    Ye, Baoxian
    ANALYST, 2011, 136 (19) : 3943 - 3949
  • [39] MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensor for sensitive determination of 8-hydroxyquinoline in cosmetic
    Guo, Sujuan
    Wu, Xianli
    Zhou, Jing
    Wang, Jing
    Yang, Baocheng
    Ye, Baoxian
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 655 (01) : 45 - 49
  • [40] Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode
    A. A. Ramadan
    H. Mandil
    M. A. Saleh
    Journal of Applied Electrochemistry, 2008, 38 : 1715 - 1720