Electrochemical detection of copper(II) at a gold electrode modified with a self-assembled monolayer of penicillamine

被引:0
|
作者
L. M. Niu
H. Q. Luo
N. B. Li
L. Song
机构
[1] Southwest University Chongqing,School of Chemistry and Chemical Engineering
[2] Ministry of Education,Key Laboratory of Ecoenvironments in the Three Gorges Reservoir Region
[3] Chang’an District Branch,Shijiazhuang Environmental Protection Bureau
来源
关键词
Gold Electrode; Accumulation Time; Penicillamine; Anodic Peak Current; Bare Gold Electrode;
D O I
暂无
中图分类号
学科分类号
摘要
A penicillamine (PCA) self-assembled monolayer (SAM) was prepared on a gold electrode. It has been found that the modified electrode exhibited a selective response to copper ions. As demonstrated by cyclic voltammetric experiments, the SAM-based electrode showed an attractive ability to preconcentrate efficiently traces of copper(II) from solutions. Under optimum conditions, the anodic peak current was proportional to the concentration of Cu(II) in the range from 8.0 × 10−7 to 1.0 × 10−4 M with a detection limit of 4.0 × 10−7 M. Moreover, this modified gold electrode is also characterized by excellent repeatability, showing a relative standard deviation of 3.2% for nine successive measurements of 1.0 × 10−5 M Cu(II). The PCA/Au SAM gold electrode was used for the determination of Cu(II) in a tap water sample and the results showed a good agreement with the data obtained by atomic emission spectrometry.
引用
收藏
页码:470 / 474
页数:4
相关论文
共 50 条