Electrochemical detection of copper(II) at a gold electrode modified with a self-assembled monolayer of penicillamine

被引:0
|
作者
L. M. Niu
H. Q. Luo
N. B. Li
L. Song
机构
[1] Southwest University Chongqing,School of Chemistry and Chemical Engineering
[2] Ministry of Education,Key Laboratory of Ecoenvironments in the Three Gorges Reservoir Region
[3] Chang’an District Branch,Shijiazhuang Environmental Protection Bureau
来源
关键词
Gold Electrode; Accumulation Time; Penicillamine; Anodic Peak Current; Bare Gold Electrode;
D O I
暂无
中图分类号
学科分类号
摘要
A penicillamine (PCA) self-assembled monolayer (SAM) was prepared on a gold electrode. It has been found that the modified electrode exhibited a selective response to copper ions. As demonstrated by cyclic voltammetric experiments, the SAM-based electrode showed an attractive ability to preconcentrate efficiently traces of copper(II) from solutions. Under optimum conditions, the anodic peak current was proportional to the concentration of Cu(II) in the range from 8.0 × 10−7 to 1.0 × 10−4 M with a detection limit of 4.0 × 10−7 M. Moreover, this modified gold electrode is also characterized by excellent repeatability, showing a relative standard deviation of 3.2% for nine successive measurements of 1.0 × 10−5 M Cu(II). The PCA/Au SAM gold electrode was used for the determination of Cu(II) in a tap water sample and the results showed a good agreement with the data obtained by atomic emission spectrometry.
引用
收藏
页码:470 / 474
页数:4
相关论文
共 50 条
  • [11] Stripping voltammetry of copper and lead using self-assembled monolayer modified gold electrode
    Shen, H
    Seliskar, CJ
    Mark, HB
    Heineman, WR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 29 - ANYL
  • [12] The electrodeposition of polypyrrole on a glutathione self-assembled monolayer modified gold electrode and its electrochemical behavior
    Zhao, FQ
    Peng, Y
    Ding, XG
    Zeng, BZ
    ELECTROANALYSIS, 2001, 13 (16) : 1367 - 1374
  • [13] Electrochemical behavior and determination of epinephrine at a gold electrode modified with self-assembled thiolactic acid monolayer
    Wang, Liang
    Bai, Junyue
    Huang, Pengfei
    Wang, Hongjing
    Zhao, Yuqing
    CHEMIA ANALITYCZNA, 2007, 52 (02): : 223 - 233
  • [14] Electrochemical detection of DNA immobilized on gold colloid particles modified self-assembled monolayer electrode with silver nanoparticle label
    Wang, MJ
    Sun, CY
    Wang, LY
    Ji, XH
    Bai, YB
    Li, TJ
    Li, JH
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) : 1117 - 1125
  • [15] INVESTIGATION OF SELF-ASSEMBLED MONOLAYER ON GOLD ELECTRODE
    SHEN, H
    SELISKAR, CJ
    HEINEMAN, WR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 : 59 - ANYL
  • [16] Simultaneous detection of ascorbic acid and dopamine at gold electrode modified with a self-assembled monolayer of cystamine
    Raj, CR
    Ohsaka, T
    ELECTROCHEMISTRY, 1999, 67 (12) : 1175 - 1177
  • [17] Genetically Modified Soybean Detection Using a Biosensor Electrode with a Self-Assembled Monolayer of Gold Nanoparticles
    Chou, Cheng-Chi
    Lin, Ying-Ting
    Kuznetsova, Iren
    Wang, Gou-Jen
    BIOSENSORS-BASEL, 2022, 12 (04):
  • [18] Immobilization of horseradish peroxidase on a self-assembled monolayer modified gold electrode for the detection of hydrogen peroxide
    Sun, JJ
    Fang, HQ
    Chen, HY
    ANALYST, 1998, 123 (06) : 1365 - 1368
  • [19] Electrochemical Atrazine Detection Using Au(111) Electrode Modified with Self-assembled Monolayer of Mercaptoquinone
    Umezawa, Noriko
    Tsurunari, Moe
    Kondo, Toshihiro
    CHEMISTRY LETTERS, 2009, 38 (08) : 766 - 767
  • [20] Electrochemical Synthesis of CdS Nanocrystals on a Gold Electrode Modified with a p-Aminothiophenol Self-Assembled Monolayer
    Wang Hui
    Xi Yan-Yan
    Zhou Jian-Zhang
    Lin Zhong-Hua
    ACTA PHYSICO-CHIMICA SINICA, 2012, 28 (06) : 1398 - 1404