Intra-aneurysmal blood flow based on patient-specific CT angiogram

被引:0
|
作者
Taku Morino
Tetsuya Tanoue
Satoshi Tateshima
Fernando Vinuela
Kazuo Tanishita
机构
[1] Keio University,Department of System Design Engineering
[2] David Geffen School of Medicine,Department of Radiological Sciences
[3] UCLA,undefined
来源
Experiments in Fluids | 2010年 / 49卷
关键词
Particle Imaging Velocimeter; Wall Shear Stress; Cerebral Aneurysm; Laser Doppler Velocimetry; Parent Artery;
D O I
暂无
中图分类号
学科分类号
摘要
To discuss the validity of the hemodynamic hypothesis of aneurysm rupture, we used a patient-specific, realistic aneurysm model to reveal the flow structure and wall shear stress distribution in two cases: one with an unruptured aneurysm and the other with a ruptured aneurysm. We used particle imaging velocimetry and laser Doppler velocimetry to measure velocity profiles of intra-aneurysmal flow. Both cases had a circulating flow along the aneurysm wall, although the second case had a recirculating zone only in the minimum phase. Differences in the wall shear stress profile may identify aneurysm rupture.
引用
收藏
页码:485 / 496
页数:11
相关论文
共 50 条
  • [31] Effects of framing coil shape, orientation, and thickness on intra-aneurysmal flow
    Woowon Jeong
    Moon Hee Han
    Kyehan Rhee
    Medical & Biological Engineering & Computing, 2013, 51 : 981 - 990
  • [32] Determining intra-aneurysmal flow for coiled cerebral aneurysms with digital fluoroscopy
    Jou, Liang-Der
    Saloner, David
    Higashida, Randall
    Biomed. Eng. Appl. Basis Commun., 1600, 2 (43-48):
  • [33] Evaluation of Intra-Aneurysmal Residual Blood Flow with the iMSDE T1-Black Blood Imaging after Flow Diverter Treatment
    Suzuki, Yume
    Toma, Naoki
    Inoue, Katsuhiro
    Ichikawa, Tomonori
    Nishikawa, Hirofumi
    Miura, Yoichi
    Fujimoto, Masashi
    Yasuda, Ryuta
    Maeda, Masayuki
    Suzuki, Hidenori
    JOURNAL OF NEUROENDOVASCULAR THERAPY, 2023, 17 (08) : 159 - 166
  • [34] A Modified Method for Creating Elastase Induced Aneurysms and Characterization of Intra-Aneurysmal Flow
    Safinia, Cyrus
    Bachour, Salam
    Hevesi, Mario
    Divani, Afshin
    NEUROLOGY, 2016, 86
  • [35] Patient-specific modeling of intracranial aneurysmal stenting
    Appanaboyina, Sunil
    Mut, Fernando
    Loehner, Rainald
    Putman, Christopher M.
    Cebral, Juan R.
    MEDICAL IMAGING 2007: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2007, 6511
  • [36] Patient-specific modeling of blood flow in the coronary arteries
    Taylor, Charles A.
    Petersen, Kersten
    Xiao, Nan
    Sinclair, Matthew
    Bai, Ying
    Lynch, Sabrina R.
    Updepac, Adam
    Schaap, Michiel
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2023, 417
  • [37] Patient-specific blood flow modelling for medical applications
    Dobroserdova, Tatiana
    Simakov, Sergey
    Gamilov, Timur
    Pryamonosov, Roman
    Sakharova, Ekaterina
    20TH INTERNATIONAL CONFERENCE ON CIRCUITS, SYSTEMS, COMMUNICATIONS AND COMPUTERS (CSCC 2016), 2016, 76
  • [38] PATIENT-SPECIFIC AORTIC VALVE BLOOD FLOW SIMULATIONS
    Kulp, Scott
    Qian, Zhen
    Vannan, Mani
    Rinehart, Sarah
    Metaxas, Dimitris
    2014 IEEE 11TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2014, : 939 - 942
  • [39] Patient-specific analysis of left ventricular blood flow
    Jones, TN
    Metaxas, DN
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 156 - 166
  • [40] Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow
    Lieber, BB
    Livescu, V
    Hopkins, LN
    Wakhloo, AK
    ANNALS OF BIOMEDICAL ENGINEERING, 2002, 30 (06) : 768 - 777