Intra-aneurysmal blood flow based on patient-specific CT angiogram

被引:0
|
作者
Taku Morino
Tetsuya Tanoue
Satoshi Tateshima
Fernando Vinuela
Kazuo Tanishita
机构
[1] Keio University,Department of System Design Engineering
[2] David Geffen School of Medicine,Department of Radiological Sciences
[3] UCLA,undefined
来源
Experiments in Fluids | 2010年 / 49卷
关键词
Particle Imaging Velocimeter; Wall Shear Stress; Cerebral Aneurysm; Laser Doppler Velocimetry; Parent Artery;
D O I
暂无
中图分类号
学科分类号
摘要
To discuss the validity of the hemodynamic hypothesis of aneurysm rupture, we used a patient-specific, realistic aneurysm model to reveal the flow structure and wall shear stress distribution in two cases: one with an unruptured aneurysm and the other with a ruptured aneurysm. We used particle imaging velocimetry and laser Doppler velocimetry to measure velocity profiles of intra-aneurysmal flow. Both cases had a circulating flow along the aneurysm wall, although the second case had a recirculating zone only in the minimum phase. Differences in the wall shear stress profile may identify aneurysm rupture.
引用
收藏
页码:485 / 496
页数:11
相关论文
共 50 条
  • [21] Evaluation of intra-aneurysmal blood flow by time density curve using digital subtraction angiography
    Tenjin, H
    Asakura, F
    Nakahara, Y
    Matsumoto, K
    Matsuo, T
    Urano, F
    Ueda, S
    STROKE, 1998, 29 (01) : 311 - 311
  • [22] The pretzel sign: angiographic pattern of tortuous intra-aneurysmal blood flow in a giant serpentine aneurysm
    Fanning, NF
    Kelleher, MO
    Ryder, DQ
    BRITISH JOURNAL OF NEUROSURGERY, 2003, 17 (01) : 67 - 71
  • [23] Patient-specific blood flow simulation through an aneurysmal thoracic aorta with a folded proximal neck
    Bevan, R. L. T.
    Sazonov, Igor
    Saksono, Prihambodo H.
    Nithiarasu, Perumal
    van Loon, Raoul
    Luckraz, Heyman
    Ashraf, Saeed
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2011, 27 (08) : 1167 - 1184
  • [24] Atrioventricular Blood Flow Simulation Based on Patient-Specific Data
    Mihalef, Viorel
    Metaxas, Dimitris
    Sussman, Mark
    Hurmusiadis, Vassilios
    Axel, Leon
    FUNCTIONAL IMAGING AND MODELING OF THE HEART, PROCEEDINGS, 2009, 5528 : 386 - +
  • [25] Transluminal visualization of intra-aneurysmal blood flow with transluminal flow imaging of three-dimensional MR angiography
    Satoh, T
    NEUROLOGICAL SURGERY, 2002, 30 (11): : 1173 - 1178
  • [26] Effects of framing coil shape, orientation, and thickness on intra-aneurysmal flow
    Jeong, Woowon
    Han, Moon Hee
    Rhee, Kyehan
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2013, 51 (09) : 981 - 990
  • [27] Impact of stent design on intra-aneurysmal flow -: A computer simulation study
    Ohta, M
    Hirabayashi, M
    Wetzel, S
    Lylyk, P
    Wata, H
    Tsutsumi, S
    Rüfenacht, DA
    INTERVENTIONAL NEURORADIOLOGY, 2004, 10 : 85 - 94
  • [28] Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction
    Shobayashi, Yasuhiro
    Tateshima, Satoshi
    Kakizaki, Ryuichi
    Sudo, Ryo
    Tanishita, Kazuo
    Vinuela, Fernando
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 : III38 - III42
  • [29] Reduction of intra-aneurysmal kinetic energy by intralumenal flow diverting devices
    Seong, Jaelhoon
    Lieber, Baruch B.
    Wakhloo, Ajay K.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 195 - 196
  • [30] A patient-specific cerebral blood flow model
    Helthuis, Jasper H. G.
    van Doormaal, Tristan P. C.
    Amin-Hanjani, Sepideh
    Du, XinJian
    Charbel, Fady T.
    Hillen, Berend
    van der Zwan, Albert
    JOURNAL OF BIOMECHANICS, 2020, 98