Evaluation of Intra-Aneurysmal Residual Blood Flow with the iMSDE T1-Black Blood Imaging after Flow Diverter Treatment

被引:1
|
作者
Suzuki, Yume [1 ]
Toma, Naoki [1 ]
Inoue, Katsuhiro [2 ]
Ichikawa, Tomonori [1 ]
Nishikawa, Hirofumi [1 ]
Miura, Yoichi [1 ]
Fujimoto, Masashi [1 ]
Yasuda, Ryuta [1 ]
Maeda, Masayuki [3 ]
Suzuki, Hidenori [1 ]
机构
[1] Mie Univ, Grad Sch Med, Dept Neurosurg, 2 174,Edobashi, Tsu, Mie 5148507, Japan
[2] Mie Univ Hosp, Dept Radiol, Tsu, Mie, Japan
[3] Mie Univ, Grad Sch Med, Dept Neuroradiol, Tsu, Mie, Japan
关键词
cerebral aneurysm; flow diverter; thrombosis; MRI; DRIVEN-EQUILIBRIUM IMSDE; INTRACRANIAL ANEURYSMS; PIPELINE EMBOLIZATION; ENDOVASCULAR TREATMENT; ANTIPLATELET THERAPY; CEREBRAL ANEURYSMS; RUPTURE; DEVICE; FEASIBILITY; STENT;
D O I
10.5797/jnet.oa.2023-0016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: We aimed to evaluate the efficacy of the "improved motion-sensitized driven-equilibrium (iMSDE)"-prepared T1-weighted black blood (T1-BB) MRI for monitoring treatment effect with a flow diverter (FD) for cerebral aneurysms. Methods: Following the exclusion of concomitant coiling and retreatment cases from 60 consecutive cases of cerebral aneurysms treated with FDs at our institution, 32 with imaging data were included in the analysis. Detectability of residual blood flow within the aneurysms was validated as follows: 1) comparison of MRI sequences (iMSDE-prepared T1-BB images, T1-weighted images [ T1WI], and time-of-flight [ TOF]-MRA) in cases of incompletely occluded aneurysms and 2) comparison of angiography and MRI sequences in the same period. Results: 1) The probability of diagnosing intra-aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB (iMSDE-prepared T1-BB vs. T1WI, p <0.001; iMSDE-prepared T1-BB vs. TOF-MRA, p <0.001). 2) The diagnostic accuracy of residual aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB than that with T1WI (p = 0.032). Furthermore, in cases of incomplete occlusion, the probability of detecting intra-aneurysmal blood flow was significantly higher with iMSDE-prepared T1-BB (iMSDE-prepared T1-BB vs. T1WI, p <0.001; iMSDE-prepared T1-BB vs. TOF-MRA, p = 0.023). Conclusion: Our results demonstrated that iMSDE-prepared T1-BB could help distinguish between blood flow and thrombus within the aneurysms after FD treatment, especially in the early stages of FD treatment.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 50 条
  • [1] CFD to Quantify Idealized Intra-Aneurysmal Blood Flow in Response to Regular and Flow Diverter Stent Treatment
    Sanches, Augusto Fava
    Shit, Suprosanna
    Oezpeynirci, Yigit
    Liebig, Thomas
    FLUIDS, 2022, 7 (08)
  • [2] Evaluation of intra-aneurysmal blood flow: Investigation of the flow in experimental aneurysms
    Asakura, F
    Tenjin, H
    Matsumoto, K
    Ueda, S
    INTERVENTIONAL NEURORADIOLOGY, 1998, 4 : 77 - 80
  • [3] Evaluation of intra-aneurysmal blood flow by digital subtraction angiography: Blood flow change after coil embolization
    Asakura, F
    Tenjin, H
    Sugawa, N
    Kimura, S
    Oki, F
    Yonekawa, Y
    SURGICAL NEUROLOGY, 2003, 59 (04): : 310 - 319
  • [4] Early angiographic changes of intra-aneurysmal flow after flow-diverter stent treatment are not predictive of therapeutic success
    Labeyrie, Paul-Emile
    Gory, Benjamin
    Sadeh-Gonike, Udi
    Huguet, Nazyed
    Sivan-Hoffmann, Rotem
    Riva, Roberto
    Courtheoux, Patrick
    Turjman, Francis
    INTERVENTIONAL NEURORADIOLOGY, 2016, 22 (06) : 682 - 686
  • [5] Simulation of Intra-Aneurysmal Blood Flow by Different Numerical Methods
    Weichert, Frank
    Walczak, Lars
    Fisseler, Denis
    Opfermann, Tobias
    Razzaq, Mudassar
    Muenster, Raphael
    Turek, Stefan
    Grunwald, Iris
    Roth, Christian
    Veith, Christian
    Wagner, Mathias
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [6] Evaluation of intra-aneurysmal hemodynamics after flow diverter placement in a patient-specific aneurysm model
    Balasso, Andrea
    Bauer, Jan S.
    Liebig, Thomas
    Dorn, Franziska
    Zimmer, Claus
    Liepsch, Dieter
    Prothmann, Sascha
    BIORHEOLOGY, 2014, 51 (06) : 341 - 354
  • [7] Transluminal visualization of intra-aneurysmal blood flow with transluminal flow imaging of three-dimensional MR angiography
    Satoh, T
    NEUROLOGICAL SURGERY, 2002, 30 (11): : 1173 - 1178
  • [8] In Vitro Evaluation of Intra-Aneurysmal, Flow-Diverter-Induced Thrombus Formation: A Feasibility Study
    Gester, K.
    Luechtefeld, I.
    Buesen, M.
    Sonntag, S. J.
    Linde, T.
    Steinseifer, U.
    Cattaneo, G.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (03) : 490 - 496
  • [9] Evaluation of intra-aneurysmal blood flow by time density curve using digital subtraction angiography
    Tenjin, H
    Asakura, F
    Nakahara, Y
    Matsumoto, K
    Matsuo, T
    Urano, F
    Ueda, S
    STROKE, 1998, 29 (01) : 311 - 311
  • [10] Delayed intra-aneurysmal migration of a flow diverter construct after treatment of a giant aneurysm of the cavernous internal carotid artery
    Gawlitza, Matthias
    Soize, Sebastien
    Manceau, Pierre-Francois
    Pierot, Laurent
    JOURNAL OF NEURORADIOLOGY, 2020, 47 (03) : 233 - 236