MRI of the knee: value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears

被引:20
|
作者
Kowalchuk, RM
Kneeland, JB
Dalinka, MK
Siegelman, ES
Dockery, WD
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Rochester, Sch Med & Dent, Rochester, NY USA
关键词
magnetic resonance imaging; comparative studies knee; menisci; knee; MRI; meniscal tears;
D O I
10.1007/s002560000212
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective. Fast spin-echo (FSE) sequences reduce imaging time compared with conventional spin-echo (CSE) sequences, but may result in blurring. Highperformance gradients permit shorter interecho spacing and use of the second echo as the effective TE (20 ms); both improvements reduce blurring. This randomized observer study compared a short TE, second-echo FSE sequence obtained using high-performance gradients and a CSE sequence with similar TR/TE for the detection of meniscal tears in the knee. Design and patients. One hundred consecutive MR examinations of the knee using FSE and CSE sequences at 1.5 T were evaluated. The FSE sequence used an effective TE of 20 ms (centered on the second echo at 2 times minimal interecho spacing) and an echo train length of 4. FSE and CSE parameters were otherwise similar. Four independent, masked readers reviewed randomized sagittal FSE and CSE sequences. Results. Cases were assessed for the presence or absence of meniscal tears and, if present, whether tears were medial or lateral and anterior or posterior. Sequence concordance was 93.5% (1496 of 1600 meniscal segments); the intermethod kappa value was 0.78. Sequence quality was graded from 1 to 5. Average quality of CSE images was slightly but statistically significantly preferred by three of the four readers. Conclusion. There was no statistically significant difference between CSE imaging and FSE imaging centered on the second echo (20 ms) using high-performance gradients for the detection of meniscal tears in the knee. There was a small preference for the quality of CSE images.
引用
收藏
页码:520 / 524
页数:5
相关论文
共 50 条
  • [21] Accuracy of 3-T MRI using fast spin-echo technique to detect meniscal tears of the knee
    Ramnath, RR
    Magee, T
    Wasudev, N
    Murrah, R
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) : 221 - 225
  • [22] Meniscal tears of the knee: Accuracy of detection with fast spin-echo MR imaging and arthroscopic correlation in 293 patients
    Cheung, LP
    Li, KCP
    Hollett, MD
    Bergman, AG
    Herfkens, RJ
    RADIOLOGY, 1997, 203 (02) : 508 - 512
  • [23] FAST SPIN-ECHO MRI IN OTOLOGY
    PHELPS, PD
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1994, 108 (05): : 383 - 394
  • [24] Comparison of fat-saturation fast spin echo versus conventional spin-echo MRI in the detection of rotator cuff pathology
    Needell, SD
    Zlatkin, MB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04): : 674 - 677
  • [25] Evaluation of anterior cruciate ligament of the knee: Comparison of conventional spin-echo (CSE) and fast spin-echo (FSE) sequence
    Cho, J
    Suh, J
    Kim, S
    Ha, D
    Kim, S
    RADIOLOGY, 1998, 209P : 463 - 463
  • [26] Interactive fast spin-echo imaging
    Busse, RF
    Riederer, SJ
    Fletcher, JG
    Bharucha, AE
    Brandt, KR
    MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (03) : 339 - 348
  • [27] FAST SPIN-ECHO IMAGING OF THE SPINE
    SCARABINO, T
    GIANNATEMPO, GM
    PERFETTO, F
    POPOLIZIO, T
    ARMILLOTTA, M
    SALVOLINI, U
    RIVISTA DI NEURORADIOLOGIA, 1995, 8 (05): : 675 - 684
  • [28] FAST SPIN-ECHO STIR IMAGING
    SMITH, RC
    CONSTABLE, RT
    REINHOLD, C
    MCCAULEY, T
    LANGE, RC
    MCCARTHY, S
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) : 209 - 213
  • [29] Fast spin-echo MR imaging
    Partovi, S
    Fram, EK
    Karis, JP
    NEUROIMAGING CLINICS OF NORTH AMERICA, 1999, 9 (03) : 553 - +
  • [30] Focal liver lesions: Characterization with conventional spin-echo versus fast spin-echo T2-weighted MR imaging
    Schima, W
    Saini, S
    Echeverri, JA
    Hahn, PF
    Harisinghani, M
    Mueller, PR
    RADIOLOGY, 1997, 202 (02) : 389 - 393