knee;
abnormalities;
ligaments;
menisci;
and cartilage;
MR;
magnetic resonance (MR);
pulse sequences;
D O I:
10.1148/radiology.203.2.9114113
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
PURPOSE: To evaluate the accuracy of a magnetic resonance (MR) imaging strategy that uses primarily fast spin-echo (SE) sequences for the diagnosis of meniscal tears. MATERIALS AND METHODS: The original clinical interpretations of MR images in 293 patients who underwent imaging for suspected internal derangement of a knee joint were correlated with results from subsequent arthroscopy. MR examination included a double-echo fast SE sequence as the only imaging in the sagittal plane. RESULTS: The sensitivity and specificity for 143 confirmed tears of the medial meniscus were 89% and 84%, respectively, while the values for 96 confirmed tears of the lateral meniscus were 72% and 93%. These values are within the ranges of values recently reported for imaging strategies relying predominantly on conventional SE sequences. CONCLUSION: Fast SE imaging of the knee can be an alternative to conventional SE imaging for the detection of meniscal tears.