Meniscal tears of the knee: Accuracy of detection with fast spin-echo MR imaging and arthroscopic correlation in 293 patients

被引:83
|
作者
Cheung, LP [1 ]
Li, KCP [1 ]
Hollett, MD [1 ]
Bergman, AG [1 ]
Herfkens, RJ [1 ]
机构
[1] STANFORD UNIV,CTR MED,DEPT DIAGNOST RADIOL,STANFORD,CA 94305
关键词
knee; abnormalities; ligaments; menisci; and cartilage; MR; magnetic resonance (MR); pulse sequences;
D O I
10.1148/radiology.203.2.9114113
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the accuracy of a magnetic resonance (MR) imaging strategy that uses primarily fast spin-echo (SE) sequences for the diagnosis of meniscal tears. MATERIALS AND METHODS: The original clinical interpretations of MR images in 293 patients who underwent imaging for suspected internal derangement of a knee joint were correlated with results from subsequent arthroscopy. MR examination included a double-echo fast SE sequence as the only imaging in the sagittal plane. RESULTS: The sensitivity and specificity for 143 confirmed tears of the medial meniscus were 89% and 84%, respectively, while the values for 96 confirmed tears of the lateral meniscus were 72% and 93%. These values are within the ranges of values recently reported for imaging strategies relying predominantly on conventional SE sequences. CONCLUSION: Fast SE imaging of the knee can be an alternative to conventional SE imaging for the detection of meniscal tears.
引用
收藏
页码:508 / 512
页数:5
相关论文
共 50 条
  • [41] MR CHOLANGIOPANCREATOGRAPHY - FINDINGS ON 3D FAST SPIN-ECHO IMAGING
    SOTO, JA
    BARISH, MA
    YUCEL, EK
    FERRUCCI, JT
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) : 1397 - 1401
  • [42] Knee Derangements: Comparison of Isotropic 3D Fast Spin-Echo, Isotropic 3D Balanced Fast Field-Echo, and Conventional 2D Fast Spin-Echo MR Imaging
    Jung, Jin Young
    Yoon, Young Cheol
    Kim, Hye Rin
    Choe, Bong-Keun
    Wang, Joon Ho
    Jung, Jee Young
    RADIOLOGY, 2013, 268 (03) : 802 - 813
  • [43] MR imaging of the knee: T1w spin-echo EPI imaging of the menisci
    Hansmann, J
    Betsch, B
    Brams, E
    Richter, GM
    Kauffmann, GW
    RADIOLOGY, 1997, 205 : 1491 - 1491
  • [44] FAST SPIN-ECHO MR IN THE DETECTION OF VERTEBRAL METASTASES - COMPARISON OF 3 SEQUENCES
    JONES, KM
    SCHWARTZ, RB
    MANTELLO, MT
    AHN, SS
    KHORASANI, R
    MUKHERJI, S
    OSHIO, K
    MULKERN, RV
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (03) : 401 - 407
  • [45] Coronal fat suppression fast spin echo images of the knee: Evaluation of 202 patients with arthroscopic correlation
    Kojima, KY
    Demlow, TA
    Szumowski, J
    Quinn, SF
    MAGNETIC RESONANCE IMAGING, 1996, 14 (09) : 1017 - 1022
  • [46] T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences
    Gryspeerdt, S
    Van Hoe, L
    Bosmans, H
    Baert, AL
    Vergote, I
    Marchal, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 211 - 215
  • [47] Focal liver lesions: Characterization with conventional spin-echo versus fast spin-echo T2-weighted MR imaging
    Schima, W
    Saini, S
    Echeverri, JA
    Hahn, PF
    Harisinghani, M
    Mueller, PR
    RADIOLOGY, 1997, 202 (02) : 389 - 393
  • [48] Fast-recovery fast spin-echo T2-weighted MR imaging: a free-breathing alternative to fast spin-echo in the pediatric abdomen
    I-Hua Huang
    Kathleen H. Emery
    Tal Laor
    Mona Valentine
    Jan Tiefermann
    Pediatric Radiology, 2008, 38 : 675 - 679
  • [49] VALUE OF UNENHANCED SPIN-ECHO MR IMAGING IN DISTINGUISHING BETWEEN SYNOVITIS AND EFFUSION OF THE KNEE
    SINGSON, RD
    ZALDUONDO, FM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (03) : 569 - 571
  • [50] Fast-recovery fast spin-echo T2-weighted MR imaging: a free-breathing alternative to fast spin-echo in the pediatric abdomen
    Huang, I-Hua
    Emery, Kathleen H.
    Laor, Tal
    Valentine, Mona
    Tiefermann, Jan
    PEDIATRIC RADIOLOGY, 2008, 38 (06) : 675 - 679