Meniscal tears of the knee: Accuracy of detection with fast spin-echo MR imaging and arthroscopic correlation in 293 patients

被引:83
|
作者
Cheung, LP [1 ]
Li, KCP [1 ]
Hollett, MD [1 ]
Bergman, AG [1 ]
Herfkens, RJ [1 ]
机构
[1] STANFORD UNIV,CTR MED,DEPT DIAGNOST RADIOL,STANFORD,CA 94305
关键词
knee; abnormalities; ligaments; menisci; and cartilage; MR; magnetic resonance (MR); pulse sequences;
D O I
10.1148/radiology.203.2.9114113
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the accuracy of a magnetic resonance (MR) imaging strategy that uses primarily fast spin-echo (SE) sequences for the diagnosis of meniscal tears. MATERIALS AND METHODS: The original clinical interpretations of MR images in 293 patients who underwent imaging for suspected internal derangement of a knee joint were correlated with results from subsequent arthroscopy. MR examination included a double-echo fast SE sequence as the only imaging in the sagittal plane. RESULTS: The sensitivity and specificity for 143 confirmed tears of the medial meniscus were 89% and 84%, respectively, while the values for 96 confirmed tears of the lateral meniscus were 72% and 93%. These values are within the ranges of values recently reported for imaging strategies relying predominantly on conventional SE sequences. CONCLUSION: Fast SE imaging of the knee can be an alternative to conventional SE imaging for the detection of meniscal tears.
引用
收藏
页码:508 / 512
页数:5
相关论文
共 50 条
  • [31] FAST SPIN-ECHO MR IMAGING OF THE BRAIN AND SPINE - CURRENT CONCEPTS
    JONES, KM
    MULKERN, RV
    SCHWARTZ, RB
    OSHIO, K
    BARNES, PD
    JOLESZ, FA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (06) : 1313 - 1320
  • [32] Non-breath-hold fast spin-echo versus breath-hold fast spin-echo and spoiled gradient-recalled echo MR imaging in the detection of hepatic tumors: Correlation with surgical findings
    Soyer, P
    Gouhiri, M
    Rondeau, Y
    Spelle, L
    Mosnier, H
    Scherrer, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) : 1199 - 1204
  • [33] MUSCULOSKELETAL MR-IMAGING - TURBO (FAST) SPIN-ECHO VERSUS CONVENTIONAL SPIN-ECHO AND GRADIENT-ECHO IMAGING AT 0.5-TESLA
    VAHLENSIECK, M
    LANG, P
    SEELOS, K
    SZE, DYH
    GRAMPP, S
    REISER, M
    SKELETAL RADIOLOGY, 1994, 23 (08) : 607 - 610
  • [34] MR imaging of hemorrhagic brain lesions: A comparison of dual-echo gradient- and spin-echo and fast spin-echo techniques
    Melhem, ER
    Patel, RT
    Whitehead, RE
    Bhatia, RG
    Rockwell, DT
    Jara, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) : 797 - 802
  • [35] Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients
    Bredella, MA
    Tirman, PFJ
    Peterfy, CG
    Zarlingo, M
    Feller, JF
    Bost, FW
    Belzer, JP
    Wischer, TK
    Genant, HK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) : 1073 - 1080
  • [36] GRASE (GRADIENT-ECHO AND SPIN-ECHO) MR IMAGING - A NEW FAST CLINICAL IMAGING TECHNIQUE
    FEINBERG, DA
    OSHIO, K
    RADIOLOGY, 1991, 181 (02) : 597 - 602
  • [37] Accelerating knee MR imaging: Compressed sensing in isotropic three-dimensional fast spin-echo sequence
    Lee, Seung Hyun
    Lee, Young Han
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2018, 46 : 90 - 97
  • [38] Use of a three-dimensional fast spin-echo MR imaging sequence in the evaluation of the cruciate ligaments of the knee
    Sonin, AH
    Penrod, BJ
    McRae, GA
    RADIOLOGY, 1997, 205 : 1490 - 1490
  • [39] T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES
    CATASCA, JV
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 61 - 67
  • [40] RAPID MR IMAGING OF THE PEDIATRIC BRAIN USING THE FAST SPIN-ECHO TECHNIQUE
    AHN, SS
    MANTELLO, MT
    JONES, KM
    MULKERN, RV
    MELKI, PS
    HIGUCHI, N
    BARNES, PD