MRI of the knee: value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears

被引:20
|
作者
Kowalchuk, RM
Kneeland, JB
Dalinka, MK
Siegelman, ES
Dockery, WD
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Rochester, Sch Med & Dent, Rochester, NY USA
关键词
magnetic resonance imaging; comparative studies knee; menisci; knee; MRI; meniscal tears;
D O I
10.1007/s002560000212
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective. Fast spin-echo (FSE) sequences reduce imaging time compared with conventional spin-echo (CSE) sequences, but may result in blurring. Highperformance gradients permit shorter interecho spacing and use of the second echo as the effective TE (20 ms); both improvements reduce blurring. This randomized observer study compared a short TE, second-echo FSE sequence obtained using high-performance gradients and a CSE sequence with similar TR/TE for the detection of meniscal tears in the knee. Design and patients. One hundred consecutive MR examinations of the knee using FSE and CSE sequences at 1.5 T were evaluated. The FSE sequence used an effective TE of 20 ms (centered on the second echo at 2 times minimal interecho spacing) and an echo train length of 4. FSE and CSE parameters were otherwise similar. Four independent, masked readers reviewed randomized sagittal FSE and CSE sequences. Results. Cases were assessed for the presence or absence of meniscal tears and, if present, whether tears were medial or lateral and anterior or posterior. Sequence concordance was 93.5% (1496 of 1600 meniscal segments); the intermethod kappa value was 0.78. Sequence quality was graded from 1 to 5. Average quality of CSE images was slightly but statistically significantly preferred by three of the four readers. Conclusion. There was no statistically significant difference between CSE imaging and FSE imaging centered on the second echo (20 ms) using high-performance gradients for the detection of meniscal tears in the knee. There was a small preference for the quality of CSE images.
引用
收藏
页码:520 / 524
页数:5
相关论文
共 50 条
  • [41] MOTION ARTIFACTS IN FAST SPIN-ECHO IMAGING
    MADORE, B
    HENKELMAN, RM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (04): : 577 - 584
  • [42] FAST SPIN-ECHO IMAGING OF THE BRAIN AND SPINE
    ATLAS, SW
    HACKNEY, DB
    LISTERUD, J
    MAGNETIC RESONANCE QUARTERLY, 1993, 9 (02) : 61 - 83
  • [43] MR contrast of ferritin and hemosiderin in the brain: comparison among gradient-echo, conventional spin-echo and fast spin-echo sequences
    Haque, TL
    Miki, Y
    Kanagaki, M
    Takahashi, T
    Yamamoto, A
    Konishi, J
    Nozaki, K
    Hashimoto, N
    Konishi, J
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (03) : 230 - 236
  • [44] FAT-SUPPRESSED MR OF THE ORBIT AND CAVERNOUS SINUS - COMPARISON OF FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO
    MUKHERJI, SK
    TART, RP
    FITZSIMMONS, J
    BELDEN, C
    MCGORRAY, S
    GUY, J
    MANCUSO, AA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (09) : 1707 - 1714
  • [45] FAST SPIN-ECHO IMAGING OF INTRACRANIAL NEOPLASMS
    TICE, HM
    JONES, KM
    MULKERN, RV
    SCHWARTZ, RB
    KALINA, P
    AHN, S
    BARNES, P
    JOLESZ, F
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (03) : 425 - 431
  • [46] T2-weighted MRI for the assessment of joint effusion: Comparative study of conventional spin-echo and fast spin-echo sequences
    Mori, S
    Kaneda, T
    Lee, K
    Kato, M
    Motohashi, J
    Ogura, I
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2004, 97 (06): : 768 - 774
  • [47] Focal nodular hyperplasia of the liver on ferumoxides-enhanced MR imaging: Comparison of conventional spin-echo, fast spin-echo and gradient-echo images
    Precetti, S
    Bellin, M
    Ghebontni, L
    Zaim, S
    Cluzel, P
    Grenier, PA
    RADIOLOGY, 1997, 205 : 1330 - 1330
  • [48] COMPARISON BETWEEN FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO IMAGING OF NORMAL AND ABNORMAL MUSCULOSKELETAL STRUCTURES IN CHILDREN AND YOUNG-ADULTS
    JARAMILLO, D
    LAOR, T
    MULKERN, RV
    INVESTIGATIVE RADIOLOGY, 1994, 29 (09) : 803 - 811
  • [49] Gradient-echo versus fat-suppressed fast spin-echo MR imaging of rotator cuff tears
    Sahin-Akyar, G
    Miller, TT
    Staron, RB
    McCarthy, DM
    Feldman, F
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 223 - 227
  • [50] FAST SPIN-ECHO IMAGING OF THE NECK - COMPARISON WITH CONVENTIONAL SPIN-ECHO, UTILITY OF FAT-SUPPRESSION, AND EVALUATION OF TISSUE CONTRAST CHARACTERISTICS
    LEWIN, JS
    CURTIN, HD
    ROSS, JS
    WEISSMAN, JL
    OBUCHOWSKI, NA
    TKACH, JA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (07) : 1351 - 1357