Simultaneous determination of caffeine and paracetamol by square wave voltammetry at poly(4-amino-3-hydroxynaphthalene sulfonic acid)-modified glassy carbon electrode

被引:100
|
作者
Tefera, Molla [1 ,2 ]
Geto, Alemnew [3 ]
Tessema, Merid [1 ]
Admassie, Shimelis [1 ]
机构
[1] Univ Addis Ababa, Dept Chem, POB 1176, Addis Ababa, Ethiopia
[2] Univ Gondar, Dept Chem, POB 196, Gondar, Ethiopia
[3] Samara Univ, Dept Chem, POB 132, Samara, Ethiopia
关键词
Poly(4-amino-3-hydroxynaphthalene sulfonic acid); Square wave voltammetry; Caffeine; Paracetamol; Coca-Cola; Pepsi-Cola and tea; DOPED DIAMOND ELECTRODE; ELECTROCHEMICAL DETERMINATION; SENSITIVE DETERMINATION; ACETAMINOPHEN; SENSOR; NANOPARTICLES; FORMULATIONS; NANOTUBES; NAFION;
D O I
10.1016/j.foodchem.2016.04.106
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Poly(4-amino-3-hydroxynaphthalene sulfonic acid)-modified glassy carbon electrode (poly(AHNSA)/GCE) was prepared for simultaneous determination of caffeine and paracetamol using square-wave voltammetry. The method was used to study the effects of pH and scan rate on the voltammetric response of caffeine and paracetamol. Linear calibration curves in the range of 10-125 mu M were obtained for both caffeine and paracetamol in acetate buffer solution of pH 4.5 with a correlation coefficient of 0.9989 and 0.9986, respectively. The calculated detection limits (S/N = 3) were 0.79 mu M for caffeine and 0.45 mu M for paracetamol. The effects of some interfering substances in the determination of caffeine and paracetamol were also studied and their interferences were found to be negligible which proved the selectivity of the modified electrode. The method was successfully applied for the quantitative determination of caffeine and paracetamol in Coca-Cola, Pepsi-Cola and tea samples. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:156 / 162
页数:7
相关论文
共 50 条
  • [11] Determination of gentamicin by using square wave anodic stripping voltammetry with poly (β-cyclodextrin-p-toluene sulfonic acid) modified glassy carbon electrode
    Muammer Burç
    Serap Titretir Duran
    Öznur Güngör
    Ali Ersin Karagözler
    Polymer Bulletin, 2024, 81 : 6381 - 6403
  • [12] A glassy carbon electrode modified with antimony and poly(p-aminobenzene sulfonic acid) for sensing lead(II) by square wave anodic stripping voltammetry
    Yi, Wen Jiao
    Li, Yang
    Ran, Gu
    Luo, Hong Qun
    Li, Nian Bing
    MICROCHIMICA ACTA, 2012, 179 (1-2) : 171 - 177
  • [13] A glassy carbon electrode modified with antimony and poly(p-aminobenzene sulfonic acid) for sensing lead(II) by square wave anodic stripping voltammetry
    Wen Jiao Yi
    Yang Li
    Gu Ran
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2012, 179 : 171 - 177
  • [14] Simultaneous Electrochemical Determination of Paracetamol and Caffeine using Activated Glassy Carbon Electrode
    Feyisa, Tilahun Yai
    Kitte, Shimeles Addisu
    Yenealem, Dereje
    Gebretsadik, Gebru
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2020, 12 (01): : 93 - 106
  • [15] Simultaneous Electrochemical Preconcentration and Determination of Dopamine and Uric acid by Square-Wave Adsorptive Stripping Voltammetry using a Poly(Safranine O)-Modified Glassy Carbon Electrode
    Filik, Hayati
    Avan, Asiye Aslihan
    Aydar, Sevda
    Arpaci, Rabia Bozdogan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (06): : 2775 - 2789
  • [16] Poly(para amino benzene sulfonic acid) Modified Glassy Carbon Electrode for the Simultaneous as well as Individual Voltammetric Determination of Guanine, Adenine and Uric Acid
    Jesny, S.
    Kumar, K. Girish
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (14) : B720 - B726
  • [17] Voltammetric determination of paracetamol, tramadol and caffeine using poly(Nile blue) modified glassy carbon electrode
    Chitravathi, S.
    Munichandraiah, N.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 764 : 93 - 103
  • [18] Simultaneous Determination of Lipophilic Vitamin Esters Using Square-Wave Voltammetry at the Glassy Carbon Electrode
    Jashari, Granit
    Musliu, Arber
    Sys, Milan
    Arbneshi, Tahir
    Mikysek, Tomas
    Svancara, Ivan
    Metelka, Radovan
    ELECTROANALYSIS, 2021, 33 (02) : 537 - 542
  • [19] SIMULTANEOUS DETERMINATION OF ASCORBIC-ACID, CAFFEINE AND PARACETAMOL IN DRUG FORMULATIONS BY DIFFERENTIAL-PULSE VOLTAMMETRY USING A GLASSY-CARBON ELECTRODE
    LAU, OW
    LUK, SF
    CHEUNG, YM
    ANALYST, 1989, 114 (09) : 1047 - 1051
  • [20] Sensitive determination of phenylephrine and chlorprothixene at poly(4-aminobenzene sulfonic acid) modified glassy carbon electrode
    Huang, Fei
    Jin, Guiying
    Liu, Yang
    Kong, Jilie
    TALANTA, 2008, 74 (05) : 1435 - 1441