Simultaneous determination of caffeine and paracetamol by square wave voltammetry at poly(4-amino-3-hydroxynaphthalene sulfonic acid)-modified glassy carbon electrode

被引:100
|
作者
Tefera, Molla [1 ,2 ]
Geto, Alemnew [3 ]
Tessema, Merid [1 ]
Admassie, Shimelis [1 ]
机构
[1] Univ Addis Ababa, Dept Chem, POB 1176, Addis Ababa, Ethiopia
[2] Univ Gondar, Dept Chem, POB 196, Gondar, Ethiopia
[3] Samara Univ, Dept Chem, POB 132, Samara, Ethiopia
关键词
Poly(4-amino-3-hydroxynaphthalene sulfonic acid); Square wave voltammetry; Caffeine; Paracetamol; Coca-Cola; Pepsi-Cola and tea; DOPED DIAMOND ELECTRODE; ELECTROCHEMICAL DETERMINATION; SENSITIVE DETERMINATION; ACETAMINOPHEN; SENSOR; NANOPARTICLES; FORMULATIONS; NANOTUBES; NAFION;
D O I
10.1016/j.foodchem.2016.04.106
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Poly(4-amino-3-hydroxynaphthalene sulfonic acid)-modified glassy carbon electrode (poly(AHNSA)/GCE) was prepared for simultaneous determination of caffeine and paracetamol using square-wave voltammetry. The method was used to study the effects of pH and scan rate on the voltammetric response of caffeine and paracetamol. Linear calibration curves in the range of 10-125 mu M were obtained for both caffeine and paracetamol in acetate buffer solution of pH 4.5 with a correlation coefficient of 0.9989 and 0.9986, respectively. The calculated detection limits (S/N = 3) were 0.79 mu M for caffeine and 0.45 mu M for paracetamol. The effects of some interfering substances in the determination of caffeine and paracetamol were also studied and their interferences were found to be negligible which proved the selectivity of the modified electrode. The method was successfully applied for the quantitative determination of caffeine and paracetamol in Coca-Cola, Pepsi-Cola and tea samples. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:156 / 162
页数:7
相关论文
共 50 条
  • [31] Simultaneous Determination of Epinephrine and Uric Acid at Poly (Guanine) Modified Glassy Carbon Electrode
    Li, Hongying
    Wang, Xueliang
    ELECTROCHEMISTRY, 2015, 83 (06) : 434 - 439
  • [32] Simultaneous determination of epinephrine and uric acid at poly (guanine) modified glassy carbon electrode
    Department of Chemistry and Chemical Engineering, Heze University, Daxue Road No.1, Heze
    274015, China
    Electrochem, 1600, 6 (434-439): : 434 - 439
  • [33] Determination of oleuropein using multiwalled carbon nanotube modified glassy carbon electrode by adsorptive stripping square wave voltammetry
    Cittan, Mustafa
    Kocak, Suleyman
    Celik, Ali
    Dost, Kenan
    TALANTA, 2016, 159 : 148 - 154
  • [34] Voltammetric Determination of Paracetamol with Poly(3,4-Ethylenedioxythiophene) Modified Glassy Carbon Electrode
    Mehretie, Solomon
    Admassie, Shimelis
    Tessema, Merid
    Solomon, Theodros
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2011, 3 (01): : 38 - 50
  • [35] Glassy carbon electrodes modified with multiwalled carbon nanotubes for the determination of ascorbic acid by square-wave voltammetry
    Kumar, Sushil
    Vicente-Beckett, Victoria
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2012, 3 : 388 - 396
  • [36] Graphene/Nafion composite film modified glassy carbon electrode for simultaneous determination of paracetamol, aspirin and caffeine in pharmaceutical formulations
    Yigit, Aydin
    Yardim, Yavuz
    Celebi, Metin
    Levent, Abdulkadir
    Senturk, Zuhre
    TALANTA, 2016, 158 : 21 - 29
  • [37] Simultaneous Determination of Caffeine and Pyridoxine in Energy Drinks using Differential Pulse Voltammetry at Glassy Carbon Electrode Modified with Nafion®
    Farag, Amir Shaaban
    Pravcova, Katerina
    Ceslova, Lenka
    Vytras, Karel
    Sys, Milan
    ELECTROANALYSIS, 2019, 31 (08) : 1511 - 1516
  • [38] Voltammetric Determination of UricAcid on Poly(p-Aminobenzene Sulfonic Acid)-Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Taskin, Gamze
    Demirtas, Fatma Gul
    Selvi, Bedrettin
    Barut, Mustafa
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 11550 - 11557
  • [39] Square Wave Anodic Stripping Voltammetric Determination of Paracetamol at Poly Luminol/Functionalized Multi-Walled Carbon Nanotubes Modified Glassy Carbon Electrode
    Gholivand, Mohammad Bagher
    Ahmadi, Elahe
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2019, 55 (12) : 1151 - 1161