Determination of gentamicin by using square wave anodic stripping voltammetry with poly (β-cyclodextrin-p-toluene sulfonic acid) modified glassy carbon electrode

被引:0
|
作者
Muammer Burç
Serap Titretir Duran
Öznur Güngör
Ali Ersin Karagözler
机构
[1] İnönü University,Department of Chemistry, Faculty of Arts and Sciences
[2] Adnan Menderes University,Department of Chemistry, Faculty of Arts and Sciences
来源
Polymer Bulletin | 2024年 / 81卷
关键词
Gentamicin; β-cyclodextrin ; p-toluene sulfonic acid; Glassy carbon electrode; Sensor;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:6381 / 6403
页数:22
相关论文
共 50 条
  • [1] Determination of gentamicin by using square wave anodic stripping voltammetry with poly (β-cyclodextrin-p-toluene sulfonic acid) modified glassy carbon electrode
    Burc, Muammer
    Titretir Duran, Serap
    Gungor, Oznur
    Karagozler, Ali Ersin
    POLYMER BULLETIN, 2024, 81 (07) : 6381 - 6403
  • [2] A glassy carbon electrode modified with antimony and poly(p-aminobenzene sulfonic acid) for sensing lead(II) by square wave anodic stripping voltammetry
    Wen Jiao Yi
    Yang Li
    Gu Ran
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2012, 179 : 171 - 177
  • [3] A glassy carbon electrode modified with antimony and poly(p-aminobenzene sulfonic acid) for sensing lead(II) by square wave anodic stripping voltammetry
    Yi, Wen Jiao
    Li, Yang
    Ran, Gu
    Luo, Hong Qun
    Li, Nian Bing
    MICROCHIMICA ACTA, 2012, 179 (1-2) : 171 - 177
  • [4] Determination of oleuropein using multiwalled carbon nanotube modified glassy carbon electrode by adsorptive stripping square wave voltammetry
    Cittan, Mustafa
    Kocak, Suleyman
    Celik, Ali
    Dost, Kenan
    TALANTA, 2016, 159 : 148 - 154
  • [5] Determination of levofloxacin in human urine by adsorptive square-wave anodic stripping voltammetry on a glassy carbon electrode
    Radi, A
    El-Sherif, Z
    TALANTA, 2002, 58 (02) : 319 - 324
  • [6] Sensitive determination of paraquat by square wave anodic stripping voltammetry with chitin modified carbon paste electrode
    El Harmoudi, H.
    Achak, M.
    Farahi, A.
    Lahrich, S.
    El Gaini, L.
    Abdennouri, M.
    Bouzidi, A.
    Bakasse, M.
    El Mhammedi, M. A.
    TALANTA, 2013, 115 : 172 - 177
  • [7] Determination of vitamin E in margarines and edible oils using square wave anodic stripping voltammetry with a glassy carbon paste electrode
    Sys, Milan
    Svecova, Blanka
    Svancara, Ivan
    Metelka, Radovan
    FOOD CHEMISTRY, 2017, 229 : 621 - 627
  • [8] A stannum/bismuth/poly(p-aminobenzene sulfonic acid) film electrode for measurement of Cd(II) using square wave anodic stripping voltammetry
    Xiong, Chang Hong
    Luo, Hong Qun
    Li, Nian Bing
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 651 (01) : 19 - 23
  • [9] Determination of mercury at a dithizone-modified glassy carbon electrode by anodic stripping voltammetry
    Huang, WS
    Zhang, SH
    ANALYTICAL SCIENCES, 2002, 18 (02) : 187 - 189
  • [10] Determination of Mercury at a Dithizone-Modified Glassy Carbon Electrode by Anodic Stripping Voltammetry
    Wensheng Huang
    Shenghui Zhang
    Analytical Sciences, 2002, 18 : 187 - 189