Patient-specific QA in MLC-based GRID therapy

被引:0
|
作者
Gao, W. [1 ]
Penagaricano, J. [1 ]
Moros, E. [1 ]
Corry, P. [1 ]
Griffin, R. [1 ]
Ivy, A. [1 ]
Youssef, E. [1 ]
Ratanatharathorn, V. [1 ]
机构
[1] Univ Arkansas Med Sci, Little Rock, AR 72205 USA
关键词
D O I
10.1118/1.2760999
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: GRID Therapy is an effective technique in treating large tumors and involves large doses in single fractions. This work is to present some dosimetric characteristics of MLC‐based GRIDs, and patient‐specific QA procedures at our institution based on film and diode dosimetry; Methods and Materials: 14 patients received GRID therapy treatments of 1500–2000 cGy at Dmax(1.5cm) in a single fraction with 6 MV photons from January 2006 to February 2007. The treatments were planned on the Pinnacle TPS using a step‐and‐shoot technique to generate chess‐board‐like patterns consisting of abutting opened‐and‐closed cells of 1cm×1cm. The treatments were delivered on a Varian Clinac 21EX with 120MLC. QA for each patient was performed with Kodax EDR2 film placed in a solid water phantom irradiated with the GRID field at normal angle and treatment SSD. Based on the measured optical density and QA MU, the MU to deliver the prescribed dose is calculated and compared with that given by the TPS for the same irradiation geometry. Similar measurements were also carried out with a diode detector in a water phantom; Results: MU derived from film measurements were consistently lower than those given by the TPS, from 1%–7%. Possible causes may be: (1) film over‐response due to high‐Z material and low energy photons in the tail region of dose profile; and (2) small variations in MLC leaf positions having measurable effect on the output of small GRID beamlets. The MUs derived from diode measurements are generally higher than and within 2% from those obtained with films. The valley‐to‐peak ratio ranged from 22%–29%, primarily depending on the number of segments in the beams. Conclusion: With the understanding of their advantages as well as limitations, both film and diode can be effectively used in routine plan verification for GRID therapy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2479 / 2479
页数:1
相关论文
共 50 条
  • [1] On the sensitivity of patient-specific IMRT QA to MLC positioning errors
    Yan, Guanghua
    Liu, Chihray
    Simon, Thomas A.
    Peng, Lee-Cheng
    Fox, Christopher
    Li, Jonathan G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (01): : 120 - 128
  • [2] On the Sensitivity of Patient-Specific IMRT QA to MLC Position Errors
    Yan, G.
    Simon, T.
    Peng, L.
    Fox, C.
    Liu, C.
    Li, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [3] Patient-specific QA for CyberKnife MLC plans using Monte Carlo
    Mackeprang, P. H.
    Vuong, D.
    Volken, W.
    Henzen, D.
    Schmidhalter, D.
    Malthaner, M.
    Mueller, S.
    Frei, D.
    Aebersold, D. M.
    Fix, M. K.
    Manser, P.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S791 - S791
  • [4] Radiochromic Film Calibration Rescaling for Patient-Specific CyberKnife MLC QA
    McCaw, T.
    Jang, S.
    Huq, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3534 - 3534
  • [5] Anatomy-based, patient-specific VMAT QA using EPID or MLC log files
    Defoor, Dewayne L.
    Vazquez-Quino, Luis A.
    Mavroidis, Panayiotis
    Papanikolaou, Nikos
    Stathakis, Sotirios
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 206 - 215
  • [6] Refinement of MLC modeling improves commercial QA dosimetry system for SRS and SBRT patient-specific QA
    Hillman, Yair
    Kim, Josh
    Chetty, Indrin
    Wen, Ning
    MEDICAL PHYSICS, 2018, 45 (04) : 1351 - 1359
  • [7] MapCHECK Patient Specific QA Cannot Suffice for MLC QA
    Backer, M.
    Yaddanapudi, S.
    Willcut, V.
    Rangaraj, D.
    Li, H.
    MEDICAL PHYSICS, 2008, 35 (06) : 2774 - +
  • [8] Feasibility of a MLC-Based Inversely Optimized Multi-Field Grid Therapy Technique
    Jin, J.
    Zhao, B.
    Huang, Y.
    Kim, J.
    Qin, Y.
    Wen, N.
    Ryu, S.
    Chetty, I.
    MEDICAL PHYSICS, 2014, 41 (06) : 561 - 561
  • [9] Applications of Deep Learning in Patient-Specific QA of MLC-Equipped Robotic SBRT and SRS
    Han, B.
    Xing, L.
    Wang, L.
    MEDICAL PHYSICS, 2019, 46 (06) : E648 - E648
  • [10] Reproducibility in patient-specific IMRT QA
    McKenzie, Elizabeth M.
    Balter, Peter A.
    Stingo, Francesco C.
    Jones, Jimmy
    Followill, David S.
    Kry, Stephen F.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03): : 241 - 251